Microcontact printing-based fabrication of digital microfluidic devices.

Digital microfluidics is a fluid manipulation technique in which discrete droplets are actuated on patterned arrays of electrodes. Although there is great enthusiasm for the application of this technique to chemical and biological assays, development has been hindered by the requirement of clean room fabrication facilities. Here, we present a new fabrication scheme, relying on microcontact printing (microCP), an inexpensive technique that does not require clean room facilities. In microCP, an elastomeric poly(dimethylsiloxane) stamp is used to deposit patterns of self-assembled monolayers onto a substrate. We report three different microCP-based fabrication techniques: (1) selective etching of gold-on-glass substrates; (2) direct printing of a suspension of palladium colloids; and (3) indirect trapping of gold colloids from suspension. In method 1, etched gold electrodes are used for droplet actuation; in methods 2 and 3, colloid patterns are used to seed electroless deposition of copper. We demonstrate, for the first time, that digital microfluidic devices can be formed by microCP and are capable of the full range of digital microfluidics operations: dispensing, merging, motion, and splitting. Devices formed by the most robust of the new techniques were comparable in performance to devices formed by conventional methods, at a fraction of the fabrication time. These new techniques for digital microfluidics device fabrication have the potential to facilitate expansion of this technology to any research group, even those without access to conventional microfabrication tools and facilities.

Biocompatible Materials↗

Proteome-on-a-chip: mirage, or on the horizon?

Proteomics has emerged as the next great scientific challenge in the post-genome era. But even the most basic form of proteomics, proteome profiling, i.e., identifying all of the proteins expressed in a given sample, has proven to be a demanding task. The proteome presents unique analytical challenges, including significant molecular diversity, an extremely wide concentration range, and a tendency to adsorb to solid surfaces. Microfluidics has been touted as being a useful tool for developing new methods to solve complex analytical challenges, and, as such, seems a natural fit for application to proteome profiling. In this review, we summarize the recent progress in the field of microfluidics in four key areas related to this application: chemical processing, sample preconcentration and cleanup, chemical separations, and interfaces with mass spectrometry. We identify the bright spots and challenges for the marriage of microfluidics and proteomics, and speculate on the outlook for progress.

Animals↗

An integrated digital microfluidic chip for multiplexed proteomic sample preparation and analysis by MALDI-MS.

To realize multiplexed sample preparation on a digital microfluidic chip for high-throughput Matrix Assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS), several fluidic functions need to be integrated. These include the generation of multiple droplets from a reservoir and parallel in-line sample purification. In this paper, we develop two critical new functions in handling protein solutions and standard proteomic reagents with electrowetting-on-dielectric (EWOD) actuation, leading to an integrated chip for multiplexed sample preparation for MALDI-MS. The first is a voltage sequence designed to generate a series of droplets from each of the three reservoirs--proteomic sample, rinsing fluid, and MALDI reagents. It is the first time that proteomic reagents have been dispensed using EWOD in an air (as opposed to oil) environment. The second is a box-in-box electrode pattern developed to allow droplet passing over dried sample spots, making the process of in-line sample purification robust for parallel processing. As a result, parallel processing of multiple sample droplets is demonstrated on the integrated EWOD-MALDI-MS chip, an important step towards high-throughput MALDI-MS. The MS results, collected directly from the integrated devices, are of good quality, suggesting that the tedious process of sample preparation can be automated on-chip for MALDI-MS applications as well as other high-throughput proteomics applications.

Angiotensin II↗

Droplet-based microfluidics with nonaqueous solvents and solutions.

In droplet-based ("digital") microfluidics, liquid droplets in contact with dielectric surfaces are created, moved, merged and mixed by applying AC or DC potentials across electrodes patterned beneath the dielectric. We show for the first time that it is possible to manipulate droplets of organic solvents, ionic liquids, and aqueous surfactant solutions in air by these mechanisms using only modest voltages (<100 V) and frequencies (<10 kHz). The feasibility of moving any liquid can be predicted empirically from its frequency-dependent complex permittivity, epsilon*. The threshold for droplet actuation in air with our two-plate device configuration is /epsilon*/>8x10(-11). The mechanistic implications of these results are discussed, along with the greatly expanded range of applications for digital microfluidics that these results suggest are now feasible.

Algorithms↗

Digital microfluidics with in-line sample purification for proteomics analyses with MALDI-MS.

An in-line sample purification method for MALDI-MS, which relies on the electrowetting-on-dielectric (EWOD)-based technique for digital microfluidics, is reported. In this method, a droplet containing peptides and impurities is moved by EWOD and deposited onto a Teflon-AF surface. A droplet of water is subsequently moved over the spot, where it dissolves and removes the impurities. A droplet containing MALDI matrix is then moved to the spot, which is analyzed by MALDI-MS. This purification method reduces the number of salt adduct peaks caused by low concentrations of impurities (e.g., 20 mM sodium phosphate), and reduces or eliminates the catastrophic effects of high concentrations of impurities (e.g., 8 M urea). The method was used to purify spots made by depositing multiple droplets of contaminated peptides. Spectra from the purified spots showed an increase in the S/N ratio as a function of the number of droplets deposited; when not purified, the S/N ratio remained constant regardless of the number of droplets. Finally, the method was used to purify protein digests for peptide mass fragment (PMF) searches, and was shown to be more efficient than the conventional method of purification with reversed-phase-packed pipet tips. We anticipate this new, in-line sample purification technique for EWOD-MALDI-MS will enable development of integrated high-throughput proteomics analysis methodologies.

Analytic Sample Preparation Methods↗

Electrowetting-based microfluidics for analysis of peptides and proteins by matrix-assisted laser desorption/ionization mass spectrometry.

A new technique for preparing samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is reported. The technique relies on electrowetting-on-dielectric (EWOD) to move droplets containing proteins or peptides and matrix to specific locations on an array of electrodes for analysis. Standard MALDI-MS reagents, analytes, concentrations, and recipes are demonstrated to be compatible with the technique. Mass spectra are comparable to those collected by conventional methods. Nonspecific adsorption of analytes to device surfaces is demonstrated to be negligible. The results suggest that EWOD may be a useful tool for automating sample preparation for high-throughput proteomics and other applications of MALDI-MS.

Equipment Design↗

Electroosmotic flow in a poly(dimethylsiloxane) channel does not depend on percent curing agent.

Poly(dimethylsiloxane) (PDMS) microfluidic devices were prepared from different ratios of "curing agent" (which contains silicon hydride groups) to "base" (which contains vinyl-terminated noncross-linked PDMS), to determine the effect of this ratio on electroosmotic flow (EOF). In fabricating devices for this purpose, a novel method for permanently enclosing PDMS channels was developed. As a supplement to the microfluidic method, the inner walls of capillaries were coated with PDMS formed from varying ratios of curing agent to base. EOF was found to be constant for PDMS formed with each ratio, which implies that the negative surface charges do not arise from chemical species present only in the base or the curing agent.

Dimethylpolysiloxanes↗

Microfluidic device for single-cell analysis.

We have developed a novel microfluidic device constructed from poly(dimethylsiloxane) using multilayer soft lithography technology for the analysis of single cells. The microfluidic network enables the passive and gentle separation of a single cell from the bulk cell suspension, and integrated valves and pumps enable the precise delivery of nanoliter volumes of reagents to that cell. Various applications are demonstrated, including cell viability assays, ionophore-mediated intracellular Ca2+ flux measurements, and multistep receptor-mediated Ca2+ measurements. These assays, and others, are achieved with significant improvements in reagent consumption, analysis time, and temporal resolution over macroscale alternatives.

Calcium↗

Flow injection analysis in a microfluidic format.

A microfluidic flow injection analysis system has been designed and evaluated. The system incorporates within a single two-layer poly(dimethylsiloxane) monolith multiple pneumatically driven peristaltic pumps, an injection loop, a mixing column, and a transparent window for fluorescence detection. Central to this device is an injection system that mimics the operation of a standard six-port, two-way valve used in conventional liquid chromatography and flow injection experiments. Analyte and carrier solutions continuously flow through this injection system allowing for measurements and sample changes to be performed rapidly and simultaneously. Injection volumes of 1.25 nL generated peak area reproducibility of better than 3% relative standard deviation. The flow injection device was evaluated with fluorescent dyes and demonstrated a detection limit of 400 zmol for fluorescein. A rudimentary sample selection system allowed calibration curves to be rapidly produced, often in less than 10 min. The hydrolysis of fluorescein diphosphate by alkaline phosphatase demonstrates that chemical assays can be carried out with this device in a manner characterized by short analysis times and low sample consumption.

Alkaline Phosphatase↗

Programmable modification of cell adhesion and zeta potential in silica microchips.

Spatial patterning of thin polyacrylamide films bonded to self-assembled monolayers on silica microchannels is described as a means for manipulating cell-adhesion and electroosmotic properties in microchips. Streaming potential measurements indicate that the zeta potential is reduced by at least two orders of magnitude at biological pH, and the adhesion of several kinds of cells is reduced by 80-100%. Results are shown for cover slides and in wet-etched silica microchannels. Because the polyacrylamide film is thin and transparent, this film is consistent with optical manipulation of cells and detection of cell contents. The spatial patterning technique is straightforward and has the potential to aid on-chip analysis of single adherent cells.

Acrylic Resins↗

Bio-microarray fabrication techniques--a review.

Microarrays with biomolecules (e.g., DNA and proteins), cells, and tissues immobilized on solid substrates are important tools for biological research, including genomics, proteomics, and cell analysis. In this paper, the current state of microarray fabrication is reviewed. According to spot formation techniques, methods are categorized as "contact printing" and "non-contact printing." Contact printing is a widely used technology, comprising methods such as contact pin printing and microstamping. These methods have many advantages, including reproducibility of printed spots and facile maintenance, as well as drawbacks, including low-throughput fabrication of arrays. Non-contact printing techniques are newer and more varied, comprising photochemistry-based methods, laser writing, electrospray deposition, and inkjet technologies. These technologies emerged from other applications and have the potential to increase microarray fabrication throughput; however, there are several challenges in applying them to microarray fabrication, including interference from satellite drops and biomolecule denaturization.

Biotechnology↗