PubMed Health⌕ Search

Biomedical subjects

Abdollah Salimi

Publications and source records attributed to Abdollah Salimi.

9 recordsLinked to original sources

Direct electrochemistry and electrocatalytic activity of catalase immobilized onto electrodeposited nano-scale islands of nickel oxide.

Cyclic voltammetry was used for simultaneous formation and immobilization of nickel oxide nano-scale islands and catalase on glassy carbon electrode. Electrodeposited nickel oxide may be a promising material for enzyme immobilization owing to its high biocompatibility and large surface. The catalase films assembled on nickel oxide exhibited a pair of well defined, stable and nearly reversible CV peaks at about -0.05 V vs. SCE at pH 7, characteristic of the heme Fe (III)/Fe (II) redox couple. The formal potential of catalase in nickel oxide film were linearly varied in the range 1-12 with slope of 58.426 mV/pH, indicating that the electron transfer is accompanied by single proton transportation. The electron transfer between catalase and electrode surface, (k(s)) of 3.7(+/-0.1) s(-1) was greatly facilitated in the microenvironment of nickel oxide film. The electrocatalytic reduction of hydrogen peroxide at glassy carbon electrode modified with nickel oxide nano-scale islands and catalase enzyme has been studied. The embedded catalase in NiO nanoparticles showed excellent electrocatalytic activity toward hydrogen peroxide reduction. Also the modified rotating disk electrode shows good analytical performance for amperometric determination of hydrogen peroxide. The resultant catalase/nickel oxide modified glassy carbon electrodes exhibited fast amperometric response (within 2 s) to hydrogen peroxide reduction (with a linear range from 1 microM to 1 mM), excellent stability, long term life and good reproducibility. The apparent Michaelis-Menten constant is calculated to be 0.96(+/-0.05)mM, which shows a large catalytic activity of catalase in the nickel oxide film toward hydrogen peroxide. The excellent electrochemical reversibility of redox couple, high stability, technical simplicity, lake of need for mediators and short preparations times are advantages of this electrode. Finally the activity of biosensor for nitrite reduction was also investigated.

Biosensing Techniques↗

Amperometric detection of insulin at renewable sol-gel derived carbon ceramic electrode modified with nickel powder and potassium octacyanomolybdate(IV).

A renewable three-dimensional chemically modified carbon ceramic electrode (CCE) containing nickel powder and K4[Mo(CN)8] was constructed by sol-gel technique. The electrochemical properties and stability of modified electrode was evaluated by cyclic voltammetry in pH range 4-10. The redox couple of [Mo(CN)8] (4-/3-) was shown both as a solute in electrolyte solution and as a component of a carbon based conducting composite electrode. The apparent electron transfer rate constant (ks) and transfer coefficient (alpha) were determined by cyclic voltammetry and they were about 17.1 and 0.57 s(-1), respectively. The catalytic activity of the modified CCE toward insulin oxidation was investigated at pH range of 3-8 by cyclic votammetry. The modified electrode showed excellent electrocatalytic activity toward insulin electroxidation at physiological pH value. The modified electrode was used for insulin detection chronoamperometrically at pH 7. Under optimized condition in amperometry method, the concentration calibration range, detection limit and sensitivity were 0.5-500 nM, 0.45 nM and 6140 nA/microM, respectively. Flow injection amperometric determination of insulin at pH 7.4, at this modified electrode yielded a calibration curve with the following characteristics, linear dynamic range 100-500 pM; sensitivity 8.1 nA/nM and detection limit 40 pM (based on S/N = 3). The inherent stability at wide pH range, high sensitivity, low detection limit, low cost and ease of preparation are of advantageous of this insulin sensor. This sensor indicates great promise for monitory insulin in chromatographic effluents.

Animals↗

Direct electrochemistry and electrocatalytic activity of catalase incorporated onto multiwall carbon nanotubes-modified glassy carbon electrode.

The direct voltammetry and electrocatalytic properties of catalase, which was adsorbed on the surface of multiwall carbon nanotubes (MWCNTs), was investigated. A pair of well-defined and nearly reversible cyclic voltammetry peaks for Fe(III)/Fe(II) redox couple of catalase adsorbed on the surface of MWCNTs at approximately -0.05 V versus reference electrode in pH 6.5 buffer solution, indicating the direct electron transfer between catalase and electrode. The surface coverage of catalase immobilized on MWCNTs glassy carbon electrode was approximately 2.4x10(-10) molcm-2. The transfer coefficient (alpha) was calculated to be 0.4, and the heterogeneous electron transfer rate constant was 80 s-1 in pH 7, indicating great facilitation of the electron transfer between catalase and MWCNTs adsorbed on the electrode surface. The formal potential of catalase Fe(III)/Fe(II) couple in MWCNTs film had a linear relationship with pH values between 2 and 11 with a slope of 58 mV/pH, showing that the electron transfer is accompanied by single proton transportation. Catalase adsorbed on MWCNTs exhibits a remarkable electrocatalytic activity toward the reduction of oxygen and hydrogen peroxide. The value for calculated Michaelis-Menten constant (1.70 mM) was high, indicating the potential applicability of the films as a new type of reagentless biosensor based on the direct electrochemistry of the catalase enzyme.

Biosensing Techniques↗

Disposable amperometric sensor for neurotransmitters based on screen-printed electrodes modified with a thin iridium oxide film.

Potential cycling in the range from -0.2 to +1.2 V is used for the electrodeposition of hydrous iridium oxide films onto a screen-printed electrode from a saturated solution of alkaline iridium(III) solution. The iridium oxide redox couple shows a stable and obvious reversible redox, with the formal potential being pH dependent in the range 1-14. The properties, stability and electrochemical properties of iridium oxide films were investigated by cyclic voltammetry. A modified electrode showed excellent catalytic activity toward the oxidation of neurotransmitters (catecholamines) over a wide pH range (2-8). The electrocatalytic behavior is further exploited as a sensitive detection scheme for adrenaline and dopamine by hydrodynamic amperometry. Under the optimized conditions, the calibration curves are linear in the concentration range 0.1-70 and 0.1-15 microM for dopamine and adrenaline determination, respectively. The detection limit and sensitivity are 30 nM and 30 nA/microM for adrenaline and 15 nM and 80 nA/microM for dopamine. Finally, the analytical performance of the modified electrode was demonstrated for the elimination of interference by uric acid in catecholamines determination when present in a 1000-fold concentration excess.

Biosensing Techniques↗

Charge-transfer triiodide ion-selective electrode based on 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane.

A new PVC membrane electrode for the triiodide ion based on a charge-transfer complex of iodine with 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as a membrane carrier was prepared. The electrode exhibits a Nernstian response for triiodide ions over a wide concentration range (1.0 x 10(-1)-1.0 x 10(-5) M) with a slope of 59.3 +/- 0.9 mV decade(-1) and a detection limit of 6.3 x 10(-6) M. It has a response time of 30 s and can be used for at least 3 months without any divergence in the potential. The potentiometric response is independent of the pH, in the pH range 1.6 - 10.0. The proposed electrode has shown very high selectivity for the triiodide ion over a wide variety of other anions. This electrode was successfully applied as an indicator electrode in the potentiometric titration of ascorbic acid and hydroquinone from pharmaceutical preparations as well as ascorbic acid in orange juice and dissolved O2 in tap water.

Journal Article↗

Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode.

A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.

Biosensing Techniques↗

Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes.

Bismuth-modified glassy carbon electrodes have been investigated for their suitability in sonoelectroanalysis. The stability of the bismuth film to the application of ultrasound was assessed via voltammetric and atomic force microscopy (AFM) studies which revealed little ablation at powers up to an intensity of 130 W cm(-2) delivered from a 25-kHz sonic horn. Furthermore, bismuth-film-modified glassy carbon electrodes were evaluated for the sonoelectroanalytical quantification of zinc and cadmium. Detection limits of 2 x 10(-7) M and 6 x 10(-9) M respectively were found after a 60-s deposition time via an acoustically assisted deposition protocol.

Journal Article↗

Abrasive immobilization of carbon nanotubes on a basal plane pyrolytic graphite electrode: application to the detection of epinephrine.

The performance of a basal plane pyrolytic graphite (bppg) electrode modified with carbon nanotubes is described. Abrasive immobilization of multiwall carbon nanotubes on a bppg electrode was achieved by gently rubbing the electrode surface on a filter paper supporting carbon nanotubes. The resulting electrode showed excellent mediation of epinephrine oxidation: a decrease in the overvoltage of the epinephrine electro-oxidation (200-500 mV) was observed as well as a dramatic increase in the peak current (4 times) compared to that seen at a bare bppg electrode. The oxidation peaks of epinephrine and ascorbic acid which overlap on bare bppg electrode were separated successfully (by ca. 220 mV) at the surface of the modified bppg electrode. The modified electrode showed good stability in comparison to most modified carbon nanotubes electrodes prepared by alternative methods.

Ascorbic Acid↗

Renewable-surface sol-gel derived carbon ceramic electrode fabricated by [Ru(bpy)(tpy)Cl]PF6 and its application as an amperometric sensor for sulfide and sulfur oxoanions.

A highly sensitive and fast responding sensor for the determination of thiosulfate, sulfite, sulfide and dithionite is described. It consists of a chemically modified carbon ceramic composite electrode (CCE) containing [Ru(bpy)(tpy)Cl]PF6 complex that was constructed by the sol-gel technique. A reversible redox couple of Ru(II)/Ru(III) was observed as a solute in acetonitrile solution and as a component of carbon based conducting composite electrode. Electrochemical behavior and stability of modified CCE were investigated by cyclic voltametry, the apparent electron transfer rate constant (kappa(S)) and transfer coefficient (a) were determined by cyclic voltametry which were about 28 s(-1) and 0.43 respectively. Electrocatalytic oxidation of S(2-), SO3(2-), S2O4(2-) and S2O3(2-) were effective at the modified electrode at significantly reduced overpotentials and in the pH range 1-11. Optimum pH values for amperometric detection of thiosulfate, dithionite, sulfide and sulfite are 7, 9, 2 and 2. Under the optimized conditions the calibration curves are linear in the concentration ranges 1-500, 3-80, 2-90 and 1-100 microM for S2O3(2-), SO3(2-), S2- and S2O4(2-) determination. The detection limit (signal to noise is 3) and sensitivity are 0.5 and 12, 2.8 and 6, 1.6 and 8, and 0.65 microM and 80 nA microM(-1) for thiosulfate, sulfite, sulfide and dithionite detection. The modified carbon ceramic electrode doped with Ru-complex shows good reproducibility, a short response time (t < 2 s), remarkable long term stability (> 6 month) and especially good surface renewability by simple mechanical polishing (RSD for eight successive polishing is 2%). The advantages of this sulfur compound amperometric detector based on ruthenium doped CCE are high sensitivity, inherent stability at a broader pH range, excellent catalytic activity, less expense and simplicity of preparation in comparison with recently published papers. This sensor can be used as a chromatographic detector for analysis of sulfur derivatives.

Journal Article↗