PubMed Health⌕ Search

Biomedical subjects

Agnès Tempez

Publications and source records attributed to Agnès Tempez.

3 recordsLinked to original sources

The Au(n) cluster probe in secondary ion mass spectrometry: influence of the projectile size and energy on the desorption/ionization rate from biomolecular solids.

A Au-Si liquid metal ion source which produces Au(n) clusters over a large range of sizes was used to study the dependence of both the molecular ion desorption yield and the damage cross-section on the size (n = 1 to 400) and on the kinetic energy (E = 10 to 500 keV) of the clusters used to bombard bioorganic surfaces. Three pure peptides with molecular masses between 750 and 1200 Da were used without matrix. [M+H](+) and [M+cation](+) ion emission yields were enhanced by as much as three orders of magnitude when bombarding with Au(400) (4+) instead of monatomic Au(+), yet very little damage was induced in the samples. A 100-fold increase in the molecular ion yield was observed when the incident energy of Au(9) (+) was varied from 10 to 180 keV. Values of emission yields and damage cross-sections are presented as a function of cluster size and energy. The possibility to adjust both cluster size and energy, depending on the application, makes the analysis of biomolecules by secondary ion mass spectrometry an extremely powerful and flexible technique, particularly when combined with orthogonal time-of-flight mass spectrometry that then allows fast measurements using small primary ion beam currents.

Bradykinin↗

Matrix-implanted laser desorption/ionization mass spectrometry.

The implantation of low-velocity massive gold clusters is shown to be a method of choice for homogeneous incorporation of a metallic matrix into the near-surface region of a solid biopolymer for subsequent laser desorption/ionization (LDI) MS analysis. Matrix implanted (MI)LDI spectra from cluster-implanted pure test peptide or tissue exhibit molecular ion peaks similar to those observed by matrix-assisted LDI. Moreover, the ion emission is very reproducible from any spot on the surface of these test samples. MILDI promises to be a powerful technique for mass spectrometric analysis of native biological samples as demonstrated by the first results on rat brain tissues.

Animals↗

Orthogonal time-of-flight secondary ion mass spectrometric analysis of peptides using large gold clusters as primary ions.

Secondary ion mass spectrometry (SIMS) for biomolecular analysis is greatly enhanced by the instrumental combination of orthogonal extraction time-of-flight mass spectrometry with massive gold cluster primary ion bombardment. Precursor peptide molecular ion yield enhancements of 1000, and signal-to-noise improvements of up to 20, were measured by comparing SIMS spectra obtained using Au(+) and massive Au(400) (4+) cluster primary ion bombardment of neat films of the neuropeptide fragment dynorphin 1-7. Remarkably low damage cross-sections were also measured from dynorphin 1-7 and gramicidin S during prolonged bombardment with 40 keV Au(400) (4+). For gramicidin S, the molecular ion yield increases slightly as a function of Au(400) (4+) beam fluence up to at least 2 x 10(13) Au(400) (4+)/cm(2). This is in marked contrast to the rapid decrease observed when bombarding with ions such as Au(5) (+) and Au(9) (+). When gramicidin S is impinged with Au(5) (+), the molecular ion yield decreases by a factor of 10 after a fluence of only 8 x 10(12) ions/cm(2). Comparison of these damage cross-sections implies that minimal surface damage occurs during prolonged Au(400) (4+) bombardment. Several practical analytical implications are drawn from these observations.

Dynorphins↗