PubMed Health⌕ Search

Biomedical subjects

Albert van den Berg

Publications and source records attributed to Albert van den Berg.

At least 19 recordsLinked to original sources

pH sensitivity of Si--C linked organic monolayers on crystalline silicon surfaces.

The electrochemical behavior of Si--C linked organic monolayers is studied in electrolyte-insulator-Si devices, under conditions normally encountered in potentiometric biosensors, to gain fundamental knowledge on the behavior of such Si electrodes under practical conditions. This is done via titration experiments, Mott-Schottky data analysis, and data fitting using a site-binding model. The results are compared with those of native SiO(2) layers and native SiO(2) layers modified with hexamethyldisilazane. All samples display pH sensitivity. The number of Si--OH groups on the alkylated samples is calculated to be less than 0.7 % of that of a pure SiO(2) insulator, which still causes a pH sensitivity of approximately 25 mV per pH unit in the pH range: 4-7. The alkylated samples hardly suffer from response changes during up- and down-going titrations, which indicates that very little oxide is additionally formed during the measurements. The pK(a) values of all samples with monolayers (4.0-4.4) are lower than that of native SiO(2) (6.0). The long-term drift (of approximately 1 mV h(-1)) is moderate. The results indicate that biosensors composed of alkylated Si substrates are feasible if a cross-sensitivity towards pH in the sensor signal is taken into account.

Journal Article↗

Assessment of a new prototype hydrogel CO( 2 ) sensor; comparison with air tonometry.

OBJECTIVE: Gastrointestinal ischemia is always accompanied by an increased luminal CO(2). Currently, air tonometry is used to measure luminal CO(2). To improve the response time a new sensor was developed, enabling continuous CO(2) measurement. It consists of a pH-sensitive hydrogel which swells and shrinks in response to luminal CO(2), which is measured by the pressure sensor. We evaluated the potential clinical value of the sensor during an in vitro and in vivo study. METHODS: The response time to immediate, and stepwise change in pCO(2) was determined between 5 and 15 kPa, as well as temperature sensitivity between 25 and 40 degrees C at two pCO(2) levels. Three sensors were compared to air tonometry (Tonocap) in healthy volunteers using a stepwise incremental exercise test, followed by a period of hyperventilation and an artificial CO(2)-peak. RESULTS: The in vitro response time to CO(2) increase and decrease was mean 5.9 and 6.6 min. The bias, precision and reproducibility were +5%, 3% and 2%, resp. Increase of 1 degrees C at constant pCO(2) decreased sensor signal by 8%. In vivo tests: The relation with the Tonocap was poor during the exercise test. The response time of the sensor was 3 min during hyperventilation and the CO(2) peak. CONCLUSION: The hydrogel carbon dioxide sensor enabled fast and accurate pCO(2) measurement in a controlled environment but is very temperature dependent. The current prototype hydrogel sensor is still too unstable for clinical use, and should therefore be improved.

Air↗

Microchip capillary electrophoresis for point-of-care analysis of lithium.

BACKGROUND: Microchip capillary electrophoresis (CE) is a promising method for chemical analysis of complex samples such as whole blood. We evaluated the method for point-of-care testing of lithium. METHODS: Chemical separation was performed on standard glass microchip CE devices with a conductivity detector as described in previous work. Here we demonstrate a new sample-to-chip interface. Initially, we took a glass capillary as a sample collector for whole blood from a finger stick. In addition, we designed a novel disposable sample collector and tested it against the clinical standard at the hospital (Medisch Spectrum Twente). Both types of collectors require < 10 microL of test fluid. The collectors contain an integrated filter membrane, which prevents the transfer of blood cells into the microchip. The combination of such a sample collector with microchip CE allows point-of-care measurements without the need for off-chip sample treatment. This new on-chip protocol was verified against routine lithium testing of 5 patients in the hospital. RESULTS: Sodium, lithium, magnesium, and calcium were separated in < 20 s. The detection limit for lithium was 0.15 mmol/L. CONCLUSIONS: The new microchip CE system provides a convenient and rapid method for point-of-care testing of electrolytes in serum and whole blood.

Antimanic Agents↗

Continuous flow microfluidic demixing of electrolytes by induced charge electrokinetics in structured electrode arrays.

A continuous flow microfluidic demixing process is realized. It utilizes high external electrical fields that are applied over electrically floating noble metal electrodes in an otherwise straight microchannel. The process converts axial electrical potential gradients into lateral molecular selective transport via a structure oriented ensemble of numerous electrodes. While the individual electrodes locally modify the electrolyte distribution by nonlinear electrokinetic effects and concentration polarization, the directed orientation of the electrode array combines the individual polarization zones to a dedicated molecular enrichment against the generated concentration gradient. A homogeneously concentrated electrolyte can be separated into arbitrarily shaped laminae of increased and depleted concentration by the presented microfluidic demixer.

Electrodes↗

The promise of nanotechnology for separation devices--from a top-down approach to nature-inspired separation devices.

An overview is given of the possible applications of nanotechnology to optimise existing separation methods and to enable new methods. Attention is paid to nanotechnological contributions in the fields of HPLC, CEC, sieves, Brownian ratchets and preconcentration units. A brief description is also given of some selection/separation mechanisms that occur in biological (cell) structures and possible future applications of these mechanisms in separation devices are investigated. Especially the active transport in discrete events occurring in cells is mentioned as a potentially powerful separating mechanism.

Chromatography, High Pressure Liquid↗

Viability study of HL60 cells in contact with commonly used microchip materials.

This paper presents a study in which different commonly used microchip materials (silicon oxide, borosilicate glass, and PDMS) were analyzed for their effect on human promyelocytic leukemic (HL60) cells. Copper-coated silicon was analyzed for its toxicity and therefore served as a positive control. With quantitative PCR, the expression of the proliferation marker Cyclin D1 and the apoptosis marker tissue transglutaminase were measured. Flow cytometry was used to analyze the distribution through the different phases of the cell cycle (propidium iodide, PI) and the apoptotic cascade (Annexin V in combination with PI). All microchip materials, with the exception of Cu, appeared to be suitable for HL60 cells, showing a ratio apoptosis/proliferation (R(ap)) comparable to materials used in conventional cell culture (polystyrene). These results were confirmed with cell cycle analysis and apoptosis studies. Precoating the microchip material surfaces with serum favor the proliferation, as demonstrated by a lower R(ap) as compared to uncoated surfaces. The Cu-coated surface appeared to be toxic for HL60 cells, showing over 90% decreased viability within 24 h. From these results, it can be concluded that the chosen protocol is suitable for selection of the cell culture material, and that the most commonly used microchip materials are compatible with HL60 culturing.

Apoptosis↗

Quantum dots based probes conjugated to annexin V for photostable apoptosis detection and imaging.

Quantum dots (Qdots) are nanoparticles exhibiting fluorescent properties that can be used for cell staining. We present here the development of quantum dots conjugated to Annexin V for specific targeting of apoptotic cells, for both apoptosis detection and staining of apoptotic "living" cells. For that purpose, Qdots Streptavidin Conjugates are coupled to biotinylated Annexin V, a 35-kDa protein which specifically recognizes and binds to phosphatidylserine (PS) moieties present on the outer membrane of apoptotic cells and not on healthy or necrotic cells. By using Annexin V, our Qdots probes are made specific for apoptotic cells. Staining of apoptotic cells was checked using fluorescence and confocal microscopy techniques and nonfixed cells. It is shown here that Qdots are insensitive to bleaching after prolonged exposure as opposed to organic dyes. This makes Qdots excellent candidates to continuously follow fast changes occurring at the membrane of apoptotic cells and facilitates time-lapse imaging as they alleviate any bleaching issue.

Annexin A5↗

Rapid inorganic ion analysis using quantitative microchip capillary electrophoresis.

Rapid quantitative microchip capillary electrophoresis (CE) for online monitoring of drinking water enabling inorganic ion separation in less than 15 s is presented. Comparing cationic and anionic standards at different concentrations the analysis of cationic species resulted in non-linear calibration curves. We interpret this effect as a variation in the volume of the injected sample plug caused by changes of the electroosmotic flow (EOF) due to the strong interaction of bivalent cations with the glass surface. This explanation is supported by the observation of severe peak tailing. Conducting microchip CE analysis in a glass microchannel, optimized conditions are received for the cationic species K+, Na+, Ca2+, Mg2+ using a background electrolyte consisting of 30 mmol/L histidine and 2-(N-morpholino)ethanesulfonic acid, containing 0.5 mmol/L potassium chloride to reduce surface interaction and 4 mmol/L tartaric acid as a complexing agent resulting in a pH-value of 5.8. Applying reversed EOF co-migration for the anionic species Cl-, SO42- and HCO3- optimized separation occurs in a background electrolyte consisting of 10 mmol/L 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) and 10 mmol/L HEPES sodium salt, containing 0.05 mmol/L CTAB (cetyltrimethylammonium bromide) resulting in a pH-value of 7.5. The detection limits are 20 micromol/L for the monovalent cationic and anionic species and 10 micromol/L for the divalent species. These values make the method very suitable for many applications including the analysis of abundant ions in tap water as demonstrated in this paper.

Electrophoresis, Microchip↗

Chip-based on-line nanospray MS method enabling study of the kinetics of isocyanate derivatization reactions.

The reaction of propyl isocyanate (2), benzyl isocyanate (3), and toluene-2,4-diisocyanate (4) with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (1) to yield the corresponding urea derivatives 5 was carried out in a continuous flow glass microfluidics chip. Real-time monitoring of the derivatization reactions was done by electrospray ionization mass spectrometry, making use of a recently reported modular chip-MS interface. Rate constants of 1.5 x 10(4), 5.2 x 10(4), and 2.4 x 10(4) M(-1) min(-1) were determined for 2, 3, and 4, respectively. Using macroscale batch conditions, the rate constants are 3-4 times lower. The faster on-chip kinetics is attributed to the more efficient molecular diffusion in the micrometer-sized channel.

Journal Article↗

Si-C linked organic monolayers on crystalline silicon surfaces as alternative gate insulators.

Herein, the influence of silicon surface modification via Si-C(n)H(2n+1) (n=10,12,16,22) monolayer-based devices on p-type 100 and n-type 100 silicon is studied by forming MIS (metal-insulator-semiconductor) diodes using a mercury probe. From current density-voltage (J-V) and capacitance-voltage (C-V) measurements, the relevant parameters describing the electrical behavior of these diodes are derived, such as the diode ideality factor, the effective barrier height, the flatband voltage, the barrier height, the monolayer dielectric constant, the tunneling attenuation factor, and the fixed charge density (Nf). It is shown that the J-V behavior of our MIS structures could be precisely tuned via the monolayer thickness. The use of n-type silicon resulted in lower diode ideality factors as compared to p-type silicon. A similar flatband voltage, independent of monolayer thickness, was found, indicating similar properties for all silicon-monolayer interfaces. An exception was the C10-based monolayer device on p-type silicon. Furthermore, low values of N(f) were found for monolayers on p-type silicon (approximately 6 x 10(11) cm(-2)). These results suggest that Si--C linked monolayers on flat silicon may be a viable material for future electronic devices.

Journal Article↗