PubMed Health⌕ Search

PubMed · 16310794

Rapid inorganic ion analysis using quantitative microchip capillary electrophoresis.

Abstract

Rapid quantitative microchip capillary electrophoresis (CE) for online monitoring of drinking water enabling inorganic ion separation in less than 15 s is presented. Comparing cationic and anionic standards at different concentrations the analysis of cationic species resulted in non-linear calibration curves. We interpret this effect as a variation in the volume of the injected sample plug caused by changes of the electroosmotic flow (EOF) due to the strong interaction of bivalent cations with the glass surface. This explanation is supported by the observation of severe peak tailing. Conducting microchip CE analysis in a glass microchannel, optimized conditions are received for the cationic species K+, Na+, Ca2+, Mg2+ using a background electrolyte consisting of 30 mmol/L histidine and 2-(N-morpholino)ethanesulfonic acid, containing 0.5 mmol/L potassium chloride to reduce surface interaction and 4 mmol/L tartaric acid as a complexing agent resulting in a pH-value of 5.8. Applying reversed EOF co-migration for the anionic species Cl-, SO42- and HCO3- optimized separation occurs in a background electrolyte consisting of 10 mmol/L 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) and 10 mmol/L HEPES sodium salt, containing 0.05 mmol/L CTAB (cetyltrimethylammonium bromide) resulting in a pH-value of 7.5. The detection limits are 20 micromol/L for the monovalent cationic and anionic species and 10 micromol/L for the divalent species. These values make the method very suitable for many applications including the analysis of abundant ions in tap water as demonstrated in this paper.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elwin X Vrouwe, Regina Luttge, Wouter Olthuis, Albert van den Berg. 2005-11-28. Rapid inorganic ion analysis using quantitative microchip capillary electrophoresis.. https://doi.org/10.1016/j.chroma.2005.10.064

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip.

Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.

Electrophoresis, Microchip↗

Rapid on-column analysis of glucosamine and its mutarotation by microchip capillary electrophoresis.

A novel electrophoretic microchip method for analyzing alpha- and beta-d-glucosamine and their interconversion in solution is presented. d-Glucosamine is labeled with fluorescamine and analyzed by capillary electrophoresis in under 2 min revealing its pH-dependent mutarotation between the alpha- and beta-anomers. The forward interconversion rates for the labeled sugars, based on an iterative analysis of the plateau heights between the peaks, are 0.72+/-0.09, 1.3+/-0.1, and 2.2+/-0.3 x 10(-3)s(-1) at pH 8.99, 9.51 and 10.01, respectively. In a separate experiment, the mutarotation of the unlabeled alpha-d-anomer was followed; the relative intensities of the alpha- and beta-peaks as a function of reaction time at pH 9.51 give a forward rate constant of 0.6+/-0.1 x 10(-3)s(-1). These results demonstrate that fast microchip separations, previously exploited for amine, amino acid, and nucleobase analysis, can also be used to analyze amino sugars and their mutarotation.

Electrophoresis, Microchip↗

Dielectrophoresis field flow fractionation of single-walled carbon nanotubes.

We report a study on Dielectrophoresis Field Flow Fractionation of Single-Wall Carbon Nanotubes (SWNTs). SWNTs, individually suspended in 1% SDBS solution, were separated by type when they passed a dielectrophoresis field flow fractionation device where 1 MHz AC voltage was supplied and the field strength was well below 1 V per mum. Furthermore, we uniquely observed enrichment of semiconductive SWNTs based on their band gap. In addition to Raman spectrum, UV-vis absorption and NIR fluorescence spectra were used for solution samples for characterization.

Electrophoresis, Microchip↗