PubMed Health⌕ Search

Biomedical subjects

Aldo Laganà

Publications and source records attributed to Aldo Laganà.

18 recordsLinked to original sources

A simple and rapid confirmatory assay for analyzing antibiotic residues of the macrolide class and lincomycin in bovine milk and yoghurt: hot water extraction followed by liquid chromatography/tandem mass spectrometry.

A rapid and simple sample preparation procedure for determining residues of antibiotics of the class of macrolides and lincomycin in whole milk and yoghurt by liquid chromatography/tandem mass spectrometry (LC/MS/MS) is presented. The method is based on the matrix solid-phase dispersion (MSPD) technique with hot water as extractant. After dispersing samples of milk and yoghurt on sand, target compounds were eluted from the MSPD column by passing through it 5 mL of water acidified with 30 mmol/L formic acid and heated at 70 degrees C. After pH adjustment and filtration, a volume of 200 microL of the aqueous extract was directly injected into the LC column. MS data acquisition was generally performed in the multiple reaction monitoring (MRM) mode, selecting two precursor ion to product ion transitions for each target compound. Hot water appeared to be an efficient extracting medium, since absolute recoveries of the analytes in milk and yoghurt were respectively 68-86% and 82-96%. The method proved to be robust as matrix effects, even though present, did not affect significantly the accuracy of the method, as evidenced by analyzing six different batches of both milk and yoghurt. Using roxithromycin (a macrolide antibiotic not used in veterinary medicine) as surrogate internal standard, the accuracy of the method at three different spike levels of the analytes in milk and yoghurt was 86-107% (RSDs not larger than 10%) and 97-117% (RSDs not larger than 13%), respectively. On the basis of a signal-to-noise ratio of 10, we estimated this method can quantify a few ppb of the analytes in milk and yoghurt. These concentrations are well below the tolerance levels of macrolides and lincomycin in milk set by both the European Union and the US Food and Drug Administration. On analyzing six yoghurt samples, we found evidence for the fact that one of the six samples was contaminated with erythromycin B.

Animals↗

Aflatoxin M1 determination in cheese by liquid chromatography-tandem mass spectrometry.

A new method for determining aflatoxin M1 (AFM1) in cheese by liquid chromatography-tandem mass spectrometry has been developed. Two methodologies were compared for sample extraction. The first one involves sample extraction with dichloromethane for hard, aged cheese or acetone for fresh cheese and includes a preliminary matrix solid-phase dispersion-extraction step before solid-phase extraction (SPE) clean-up by a Carbograph-4 cartridge. The second method uses a water/methanol solution (90:10, v/v) extraction at 150 degrees C before clean-up. The average recoveries of AFM1 from samples spiked at levels of 0.25-0.45 microg/kg, were 81-92% and the precision (RSD) ranged from 3 to 7% with the first method, whilst the average recoveries were 79-84%, and RSD ranged from 7 to 15% for the second method. Due to different matrix effect, the quantification limits were 0.019-0.025 microg/kg in the first case and 0.048-0.143 microg/kg in the second one, depending on cheese typology.

Aflatoxin M1↗

Simple and rapid determination of anatoxin-a in lake water and fish muscle tissue by liquid-chromatography-tandem mass spectrometry.

Anatoxin-a (AN) is a powerful neurotoxin that can be produced by cyanobacteria in eutrophic freshwaters. Consequently, AN can contaminate lakes, rivers and basins destined for drinking water and aquaculture. Two simple, specific and sensitive procedures for determining AN in lake water and fish muscle tissue are presented. Both analytical protocols are based on liquid-chromatography (LC)-tandem mass spectrometry (MS) with electrospray ionization. MS data were acquired in the multi reaction monitoring mode by selecting four precursor to product ion transitions. After filtration, AN in lake water was analyzed by directly injecting 0.5 ml of the aqueous sample in the LC column. Analysis of AN in fish muscle tissue involved the matrix solid-phase dispersion technique. The analyte was extracted from tissue by 4 ml of water acidified to pH 2 and heated at 80 degrees C. After acidification and filtration, 0.2 ml of the aqueous extract was injected in the LC column. Analyte recovery ranged between 71 and 79% and was not substantially affected by both the analyte concentration and the type of fish. Phenylalanine is an essential amino acid invariably present in any animal tissue. Like AN, this amino acid produces a pseudo molecular ion at m/z 166, it has a very similar fragmentation pattern and LC retention time. This method is able to prevent identifying phenylalanine for AN as the latter compound is eluted more than 1 min before the former one and the two compounds have remarkably different relative ion signal intensities. On the basis of a signal-to-noise ratio of 10, limits of quantification of AN in water and fish fillet were estimated to be 13 ng/l and 0.5 ng/g, respectively.

Animals↗

Monitoring algal toxins in lake water by liquid chromatography tandem mass spectrometry.

Microcystins (MCs) and cylindrospermopsin (CYL) are potent natural toxins produced by cyanobacteria (blue-green algae) that grow worldwide in eutrophic freshwaters and cause animal and human water-based toxicoses. The main purpose of this work has been assessing the contamination levels of some MCs and CYL in eutrophic Italian lake (Albano) water. To do this, we have developed an original analytical method involving MC extraction with a sorbent (Carbograph 4) cartridge. CYL is a highly polar compound that is scarcely retained by any sorbent material. To analyze this toxin, we directly injected 0.5 mL of filtered lake water into the liquid chromatography (LC) column. Analytes were quantified by LC coupled to tandem mass spectrometry in the multireaction monitoring mode. The recovery of five selected MCs added to an analyte free lake water sample at three different concentrations (50, 150, and 500 ng/L) ranged between 93 and 103% with RSD values no larger than 8%. Limits of quantification (LOQ) of the five MCs were within the 2-9 ng/L range, whereas the LOQ of CYL was 300 ng/L. The occurrence and abundance of cyanotoxins in Lake Albano was monitored over four months (Sept-Dec 2004) by analyzing water samples collected monthly at the center of the lake and at different depths (from 0 to -30 m). During survey and with the MS/MS system operating in the parent ion scan mode, we individuated two demethylated forms of MC-RR and one demethylated variety of MC-LR. Demethylated MC-RRs are known to be even more toxic than MC-RR toward zooplanktic grazers. CYL was the most-abundant toxin during the first three monitoring months. To the best of our knowledge, this is the first work reporting concentration levels of CYL in lake water.

Acetonitriles↗

A rapid confirmatory method for analyzing tetracycline antibiotics in bovine, swine, and poultry muscle tissues: matrix solid-phase dispersion with heated water as extractant followed by liquid chromatography-tandem mass spectrometry.

A rapid, specific, and sensitive procedure for determining four widely used tetracycline antibiotics and three related epimers in bovine, swine, and poultry muscle tissues is presented. The method is based on the matrix solid-phase dispersion technique with heated water as the extractant followed by liquid chromatography (LC)-tandem mass spectrometry (MS) equipped with an electrospray ion source. Target compounds were extracted from tissues with 5 mL of water heated at 70 degrees C. After acidification and filtration, 100 microL of the aqueous extract was injected in the LC column. MS data acquisition was performed in the multireaction monitoring mode, selecting two precursor ion to product ion transitions for each target compound. Heated water appeared to be an excellent extractant, since the absolute recovery data ranged between 70 and 78%. The accuracy of the method was determined at three spike levels, using minocycline as a surrogate analyte, in any different kind of muscle tissues considered and varied between 88 and 109% with relative standard deviations ranging between 3 and 11%. Limits of quantification were estimated to range between 1 (chlortetracycline) and 9 ng/g (4-epioxytetracycline), based on a signal-to-noise ratio of 10, and are well below the tolerance levels set by the European Union. The effects of the extraction temperature, volume of the extractant, and washing of the material supporting the biological matrix with ethylenediamine tetraacetic disodium salt on the analyte recovery were studied.

Animals↗

Diastereoselective fragmentation of chiral alpha-aminophosphonic acids/metal ion aggregates.

Diastereomeric clusters of general formula [MAB(2)](+) and [MA(2)B](+) (M = Li(I), Na(I), Ag(I), Ni(II)-H, or Cu(II)-H; A = (R)-(-)- and (S)-(+)-(1-aminopropyl)phosphonic acid; B = (1R)-(-)- and (1S)-(+)-(1-aminohexyl)phosphonic acid) have been readily generated in the electrospray ionization (ESI) source of a triple-quadrupole mass spectrometer and their collision-induced dissociation (CID) investigated. CID of diastereomeric complexes, e.g. [MA(S)(B(S))(2)](+) and [MA(R)(B(S))(2)](+), leads to fragmentation patterns characterized by R(homo) = [MA(S)B(S)](+)/[M(B(S))(2)](+) and R(hetero) = [MA(R)B(S)](+)/[M(B(S))(2)](+) abundance ratios, which depend upon the relative stability of the diastereomeric [MA(S)B(S)](+) and [MA(R)B(S)](+) complexes in the gas phase. The chiral resolution factor R(chiral) = R(homo)/R(hetero) is found to depend not only on the nature of the M ion but also on that of the fragmenting species, whether [MAB(2)](+) or [MA(2)B](+). The origin of this behavior is discussed.

Journal Article↗

Development of a multiresidue method for analyzing herbicide and fungicide residues in bovine milk based on solid-phase extraction and liquid chromatography-tandem mass spectrometry.

This report describes a liquid chromatography (LC)-tandem mass spectrometry (MS) multiresidue method for determining traces of 30 base/neutral/acid herbicides and fungicides in bovine whole milk. Four milliliters of milk was spiked with the analytes and two surrogate analytes (SAs) and then diluted with 35 mL of a water/methanol solution (50:50, v/v). This mixture was passed through a 0.5-g Carbograph 4 cartridge. After washings, analytes were re-extracted by back-flushing the cartridge with 1.5 mL of methanol followed by 6 mL of methylene chloride/methanol (80:20, v/v), 50 mmol/L formic acid. After partial solvent removal down to about 0.1, 0.15 mL of 1 mmol/L formic acid aqueous solution and an internal standard (IS) were added. After filtration, 50 microL of the final extract was then introduced into the LC analytical column. During the chromatographic run, the MS system was operated in both positive and negative ion modes. MS data acquisition was performed in the multi-reaction monitoring mode, selecting two precursor ion>product ion transitions for each target compound, except for pentachlorophenol. On analyzing six milk samples from different sources, absolute recovery of the analytes and the two SAs ranged between 78% and 104% with RSDs not larger than 13%. The accuracy of the method at three different spike levels was assessed by adding the two SAs to analyte-containing milk samples and varied between 82% and 120% with RSDs not larger than 11%. Limits of quantification were estimated to range between 0.008 and 1.4 microg/L. Compared to the Carbograph 4 cartridge, one filled with a N-vinylpyrrolidone-m-divinylbenzene co-polymer (Oasis HLB) sorbent was much less efficient in recovering several of the acidic herbicides considered and, in addition, its relative final extract produced a severe negative matrix effect that drastically weakened ion signal intensities of several non acidic analytes.

Animals↗

Liquid chromatography/tandem mass spectrometric confirmatory method for determining aflatoxin M1 in cow milk: comparison between electrospray and atmospheric pressure photoionization sources.

A liquid chromatography/electrospray (ESI)-tandem mass spectrometric method for the measurement of aflatoxin M1 (AFM1) in milk is described. Milk sample after protein precipitation with acetone was cleaned-up with a Carbograph-4 cartridge. Performances of the ESI source were compared with those of the atmospheric pressure photoionization source (APPI). Although a method quantification limit (MQL) of 6 ng/kg could be achieved operating with APPI source with respect to an MQL of 12 ng/kg with ESI, all the other performances being similar, then ESI was preferred as being more robust and widespread at present.

Aflatoxin B1↗

Automated on-line solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry method for the determination of ochratoxin A in wine and beer.

An automated on-line solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry (SPE-LC-ESI-MS/MS) method was developed for the determination of ochratoxin A (OTA) in alcoholic beverages. Mean recoveries for wine and beer were, respectively, 75 and 82%. Detection was achieved in negative ionization with a Q TRAP mass spectrometer operating in multiple-reaction monitoring (MRM) mode or enhanced product ion (EPI) mode, using the third quadrupole as linear ion trap. The MRM mode turned out to be more sensitive; the method allowed accurate determination of OTA in the range of 0.01-25 ng mL(-1) using external calibration. Within-day and between-day relative standard deviation percentages were <6.2 and <9.1%, respectively. In EPI mode, fragmentation spectra at the limit of quantification (0.03 ng mL(-1)) and good linearity could be obtained. Application of the method (MRM mode) to the analysis of several wine and beer samples purchased in local stores revealed OTA levels in the ranges of 0.03-1.44 ng mL(-1) for wines and 0.02-0.14 ng mL(-1) for beers.

Autoanalysis↗

Simple confirmatory assay for analyzing residues of aminoglycoside antibiotics in bovine milk: hot water extraction followed by liquid chromatography-tandem mass spectrometry.

A simple, selective and sensitive procedure for determining nine widely used aminoglycoside antibiotics (AGs) in bovine whole milk is presented. It is based on matrix solid-phase dispersion with heated water, at 70 degrees C, as extractant followed by liquid chromatography (LC)-tandem mass spectrometry (MS) using an electrospray ion source. After acidification and filtration, 0.2 ml of the aqueous extract was injected into the LC column. MS data acquisition was performed in the multi reaction monitoring mode, selecting two (three, when possible) precursor ion > product ion transitions for each target compound. Analyte recoveries ranged between 70 and 92%. Using aminosidine (an AG not used in veterinary medicine) as surrogate internal standard, the accuracy of the method at three spike levels varied between 80 and 107% with R.S.D. not larger than 11%. The limits of quantification were between 2 ng/ml (apramycin) and 13 ng/ml (streptomycin). They are well below the tolerance levels set by both the European Union and the U.S. Food and Drug Administration.

Aminoglycosides↗

Determination of type B fumonisin mycotoxins in maize and maize-based products by liquid chromatography/tandem mass spectrometry using a QqQlinear ion trap mass spectrometer.

A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the type B fumonisin mycotoxins in corn-based foodstuffs is described. Fumonisins FB1 and FB2 were extracted from a 1 g sample by homogenization with acetonitrile/water (75:25, v/v, 50 mmol/L formic acid, 25 mL final volume) and the extract was defatted on C18 phase. Volumes of 5 mL of crude extracts were cleaned up on Carbograph-4 cartridges. The final solution was analyzed by HPLC with electrospray ionization mass spectrometry in positive ion mode using multiple reaction monitoring with a QqQ linear ion trap mass spectrometer. Recoveries for spiked corn-based foodstuffs ranged from 91-105% (RSD% < or =8%), and method detection limits were < or =2 ng/g for FB1 and < or =1 ng/g for FB2. Two different spiking levels were tested (5000 and 100 ng/g for FB1, 1000 and 20 ng/g for FB2). Quantitation was achieved by an external calibration procedure using matrix-matched standards, with diclofenac added post-cleanup as internal standard for the LC/MS/MS analyses. Calibration curves showed linearity in the concentration range 0.005-5 ng/microL of final extract (0.992 < or = R2< or =0.995). Two other fumonisins, FB3 and FB4, were identified in naturally contaminated samples of corn meal using an information-dependent acquisition protocol that looped three experiments, including neutral loss scan, enhanced resolution scan, and enhanced product ion scan. FB3 and FB4 quantitation was estimated as peak area ratios relative to the FB2 response in view of the lack of both standards. This work also includes an application of the present LC/MS/MS method to some maize and maize-based product samples (corn meal, cornflakes and popcorn) collected from Italian stores. FB1 and FB2 contamination levels exceeding the European Union recommendation were found in 8 out of 15 corn meal samples.

Chromatography, High Pressure Liquid↗

Development of a multiresidue method for analysis of major Fusarium mycotoxins in corn meal using liquid chromatography/tandem mass spectrometry.

A sensitive and reliable liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method has been developed to determine, in a single run, eight trichothecenes, three fumonisins, zearalenone and alpha-zearalenol, in corn meal samples. LC and MS conditions were varied to find the best compromise in terms of sensitivity and separation. An acceptable compromise was obtained using a C18 column thermostatted at 45 degrees C and a mobile phase gradient of methanol/water with 10 mmol/L formate buffer (pH 3.8). A multiple reaction monitoring program, in which fumonisins and trichothecenes (except nivalenol and deoxynivalenol) are acquired in positive ESI as [M+H]+ or [M+NH4]+, and all other compounds in negative ESI, was developed to match appropriate retention time windows. Sample preparation used a simple homogenization of the corn meal sample with acetonitrile/water (75:25, v/v) followed by extraction on a C18 cartridge and clean-up on a cartridge containing graphitized carbon black. Method detection limits were in the range 2-14 ng/g, with the exception of nivalenol (27 ng/g), deoxynivalenol (40 ng/g) and 15-acetyldeoxynivalenol (30 ng/g). Good accuracy (recoveries 81-104%) and precision (RSD 4-11%) were obtained by performing calibration using a spiked analyte-free extract.

Chromatography, Liquid↗

Identification and mass spectrometric characterization of glycosylated flavonoids in Triticum durum plants by high-performance liquid chromatography with tandem mass spectrometry.

A mass spectrometric method for extensive detection and semi-quantitative determination of flavonoid glycosides in stem and leaves of young Triticum durum plants is presented. About 100 g of sample were lyophilized and ground, and the compounds of interest were then extracted, cleaned-up, and fractionated using high-performance liquid chromatography (HPLC). Tandem mass spectrometry analyses were performed using a quadrupole-linear ion trap instrument with an information-dependent data acquisition (IDA) protocol that looped two experiments, enhanced MS scan and enhanced product ion scan. Various glycoconjugates, which are all derivatives of only four flavones, apigenin, luteolin, chrysoeriol and tricin, were identified and belong to the following categories: 7 monoglycosides, 31 diglycosides, 15 triglycosides and 1 tetraglycoside. Among these some acylated glycosides were found. Tricin derivatives are present exclusively as O-glycosides, while apigenin and luteolin are present always as C-glycosides. Semi-quantitative estimation was performed by using the monoglycoside and diglycoside of quercetin as internal standards.

Apigenin↗

Simple and rapid assay for analyzing residues of carbamate insecticides in bovine milk: hot water extraction followed by liquid chromatography-mass spectrometry.

A simple, specific and rapid procedure for determining six largely used carbamate insecticides in bovine whole milk is here presented. This method is based on the matrix solid-phase dispersion technique with heated water as extractant followed by liquid chromatography (LC)-mass spectrometry (MS) equipped with a single quadrupole and an electrospray ion source. Target compounds were extracted from milk by water heated at 90 degrees C. After acidification and filtration, 0.2 mL of the aqueous extract was injected in the LC column. MS data acquisition was performed in the selected ion-monitoring mode, selecting three ions for each target compound. Heated water appeared to be an excellent extractant, since absolute recovery data ranged between 76 and 104% with R.S.D. not larger than 8%. Using butocarboxim (an obsolete carbamate insecticide) as surrogate internal standard, the accuracy of the analysis at three spike levels varied between 85 and 105% with R.S.D. not larger than 9%. On the basis of a signal-to-noise ratio of 10, limits of quantification were estimated to range between 3 ppb (propoxur) and 8 ppb (pirimicarb). The effects of temperature, volume and flow rate of the extractant on the analyte recovery were studied.

Animals↗

NMR-based metabonomic study of transgenic maize.

The aim of this research was to verify the possibility of identifying and classifying maize seeds obtained from transgenic plants, in different classes according to the modification, on the basis of the concerted variation in metabolite levels detected by NMR spectra. It was possible to recognise the discriminant metabolites of transgenic samples as well as to classify non-a priori defined samples of maize. It is important to underline that the obtained results are useful to point out the metabolic consequences of a specific genic modification on a plant, without using a targeted analysis of the different metabolites, in fact it was possible to classify the seeds also without the complete assignment of the spectra. The analysis was performed by applying multivariate techniques (principal component analysis and partial least squares-discriminant analysis) to NMR data.

Gene Expression↗

Liquid chromatography/tandem mass spectrometry for the identification and determination of trichothecenes in maize.

A reliable, sensitive and selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to determine four trichothecene mycotoxins (nivalenol, deoxynivalenol, fusarenon X and 3-acetyldeoxynivalenol) in maize. Sample preparation was performed by extracting the analytes with a mixture of acetonitrile and water, followed by a solid-phase extraction with Carbograph-4 cartridges as the purification step. For the LC/MS/MS analysis two interfacing systems, Turbo IonSpray (TISP) and atmospheric pressure chemical ionization (APCI), were compared in both negative and positive ion modes. LC and MS parameters were optimized to achieve better results and sensitivity. The effect of mobile phase modifiers such as ammonium acetate and formic acid on the ionization yield was also evaluated. The best results were obtained using the electrospray ionization (ESI) interface in negative ion mode and the multiple reaction monitoring mode (MRM) for the quantitation. The detection limits ranged between 10 ng/g for fusarenon X and 1.5 ng/g for deoxynivalenol. A linear working range was achieved with a standard deviation between 3 and 10% and recovery rates from the maize samples above 81%. The procedure was applied to the analysis of a set of maize samples collected from farms located in different areas of northern and central Italy. The investigated samples turned out to be contaminated primarily with deoxynivalenol and, to a minor extent, with its derivatives.

Chromatography, High Pressure Liquid↗

Sample preparation for determination of macrocyclic lactone mycotoxins in fish tissue, based on on-line matrix solid-phase dispersion and solid-phase extraction cleanup followed by liquid chromatography/tandem mass spectrometry.

A new method based on matrix solid-phase dispersion (MSPD) on-line with a solid-phase extraction (SPE) cleanup process followed by liquid chromatography with tandem mass spectrometry (LC/MS/MS) is presented for the determination of 3 macrocyclic lactone mycotoxins in fish tissues: zearalenone, alpha-zearalenol, and beta-zearalenol. The sample was prepared in a device that used a reversed-phase material (C18) or a normal-phase material (neutral alumina) as a matrix dispersing agent, and a graphitized carbon black cartridge was used for sequential cleanup by SPE. LC/MS/MS was used for selective determination. Isocratic elution with acetonitrile-methanol-water was used for LC separation; for MS/MS, 2 types of interfaces (a pneumatically assisted electrospray ionization interface or an atmospheric pressure chemical ionization interface) were evaluated and compared in terms of the intensity of the total ion current produced by each analyte. The use of highly selective MSPD on-line with SPE for sample preparation before analysis allowed the removal of interfering matrix compounds present in tissue extracts that would otherwise cause severe ionization suppression of zearalenone and its metabolites during the ionization process. Average recoveries at 100 ng/g were between 83 and 103% with C18 and > or = 67% with neutral alumina; the relative standard deviations were < 11% with C18 and < 18% with alumina. The limits of detection ranged from 0.1 to 1.0 ng/g. Sample preparation is simple to perform, no special technical equipment is required, and solvent volumes are minimal.

Animals↗