Publications and source records attributed to Aleksey V Tolmachev.

10 recordsLinked to original sources

Mass measurement accuracy in analyses of highly complex mixtures based upon multidimensional recalibration.

Mass spectrometry combined with a range of on-line separation techniques has become a powerful tool for characterization of complex mixtures, including protein digests in proteomics studies. Accurate mass measurements can be compromised due to variations that occur in the course of an on-line separation, e.g., due to excessive space charge in an ion trap, temperature changes, or other sources of instrument "drift". We have developed a multidimensional recalibration approach that utilizes existing information on the likely mixture composition, taking into account variable conditions of mass measurements, and that corrects the mass calibration for sets of individual peaks binned by, for example, the total ion count for the mass spectrum, the individual peak abundance, m/z value, and liquid chromatography separation time. The multidimensional recalibration approach uses a statistical matching of measured masses in such measurements, often exceeding 105, to a significant number of putative known species likely to be present in the mixture (i.e., having known accurate masses), to identify a subset of the detected species that serve as effective calibrants. The recalibration procedure involves optimization of the mass accuracy distribution (histogram), to provide a more confident distinction between true and false identifications. We report the mass accuracy improvement obtained for data acquired using a TOF and several FTICR mass spectrometers. We show that the multidimensional recalibration better compensates for systematic mass measurement errors and also significantly reduces the mass error spread: i.e., both the accuracy and precision of mass measurements are improved. The mass measurement improvement is found to be virtually independent of the initial instrument calibration, allowing, for example, less frequent calibration. We show that this recalibration can provide sub-ppm mass measurement accuracy for measurements of a complex fungal proteome tryptic digest and provide improved confidence or numbers of peptide identifications.

Calibration↗

Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface.

We report on a new electrodynamic ion funnel that operates at a pressure of 30 torr with no loss of ion transmission. The enhanced performance compared with previous ion funnel designs optimized for pressures of <5 torr was achieved by reducing the ion funnel capacitance and increasing the RF drive frequency (1.7 MHz) and amplitude (100-170 V peak-to-peak). No degradation of ion transmission was observed for pressures from 2 to 30 torr. The ability to operate at higher pressure enabled a new tandem ion funnel mass spectrometer interface design that can accommodate a greater gas load (e.g., from an ESI source). When combined with a multicapillary inlet, the interface provided more efficient introduction of ions, resulting in a significant enhancement in mass spectrometer sensitivity and detection limits.

Equipment Design↗

Theoretical and experimental evaluation of the low m/z transmission of an electrodynamic ion funnel.

The transmission of ions at low m/z can often be either necessary for an application or problematic (e.g., when large numbers of low m/z ions consume a large fraction of an ion trap's capacity). The low m/z ion transmission limit of an electrodynamic ion funnel has been characterized using both experimental and theoretical approaches. A theoretical model is developed based on a series of infinite wire conductors that represent the ring electrodes of the ion funnel. Mathematical relationships for both low and high m/z cutoffs of the idealized two-dimensional system are derived. The low m/z cutoff is also evaluated through a series of experiments that show it is influenced by both the RF frequency and the DC electric field gradient. However, unlike multipole ion guides, there is no marked dependence of the low m/z cutoff on the RF amplitude, in agreement with theoretical results. With this new understanding, ion funnels can be designed and configured to better match the m/z range requirements for various applications.

Electrochemistry↗

High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces.

The utility of ion mobility spectrometry (IMS) for separation of mixtures and structural characterization of ions has been demonstrated extensively, including in biological and nanoscience contexts. A major attraction of IMS is its speed, several orders of magnitude greater than that of condensed-phase separations. Nonetheless, IMS combined with mass spectrometry (MS) has remained a niche technique, substantially because of limited sensitivity resulting from ion losses at the IMS-MS junction. We have developed a new electrospray ionization (ESI)-IMS-QTOF MS instrument that incorporates electrodynamic ion funnels at both front ESI-IMS and rear IMS-QTOF interfaces. The front funnel is of the novel "hourglass" design that efficiently accumulates ions and pulses them into the IMS drift tube. Even for drift tubes of 2-m length, ion transmission through IMS and on to QTOF is essentially lossless across the range of ion masses relevant to most applications. The rf ion focusing at the IMS terminus does not degrade IMS resolving power, which exceeds 100 (for singly charged ions) and is close to the theoretical limit. The overall sensitivity of the present ESI-IMS-MS system is comparable to that of commercial ESI-MS, which should make IMS-MS suitable for analyses of complex mixtures with ultrahigh sensitivity and exceptional throughput.

Electrochemistry↗

Variable low-mass filtering using an electrodynamic ion funnel.

An adjustable low-mass filter has been developed for an electrospray ionization (ESI) source to block ions associated with unwanted background species from entering the mass spectrometer. The low-mass filter is made by using an adjustable potential energy barrier from the conductance-limiting plate of an electrodynamic ion funnel, which prohibits species with higher ion mobilities from exiting the ESI source. We show that this arrangement provides a linear voltage adjustment for low-mass filtering from m/z 0 to 500. Mass filtering above m/z 500 is also performed; however, higher-mass species are attenuated. The mass filter was tested with a liquid chromatography/mass spectrometry (LC/MS) analysis of a bovine serum albumin (BSA) tryptic digest and resulted in the ability to block low-mass, background species, which accounted for 40-70% of the total ion current immediately behind the ESI source during peak elution and detection.

Animals↗

Collisional activation of ions in RF ion traps and ion guides: the effective ion temperature treatment.

Ion transfer and storage using inhomogeneous radio frequency (RF) electric fields in combination with gas-assisted ion cooling and focusing constitutes one of the basic techniques in mass spectrometry today. The RF motion of ions in the bath gas environment involves a large number of ion-neutral collisions that leads to the internal activation of ions and their effective "heating" (when a thermal distribution of internal energies results). The degree of ion activation required in various applications may range from a minimum level (e.g., slightly raising the average internal energy) to an intense level resulting in ion fragmentation. Several research groups proposed using the effective temperature as a measure of ion activation under conditions of multiple ion-neutral collisions. Here we present approximate relationships for the effective ion temperature relevant to typical operation modes of RF multipole devices. We show that RF ion activation results in near-thermal energies for ions occupying an equilibrium position at the center of an RF trap, whereas increased ion activation can be produced by shifting ions off-center, e.g., by means of an external DC electric field. The ion dissociation in the linear quadrupole ion trap using the dipolar DC ion activation has been observed experimentally and interpreted in terms of the effective ion temperature.

Fibrinopeptide A↗

Suppression of the lower charge state ions in the external accumulation RF multipole with a reduced trapping DC potential.

Radio frequency (RF) multipoles are increasingly used in mass spectrometry as two-dimensional ion traps for ion accumulation and preselection. It was reported recently that ions having lower charge states, in particular singly charged ions, can be efficiently removed from such an ion trap when reduced DC trapping voltages are applied. This procedure can be useful for removing singly charged species contributing chemical noise to mass spectra of complex biomolecular samples, e.g., solvent contaminants in LC-MS or relatively low MW ampholytes in CIEF-MS experiments. We consider a physical mechanism and derive relationships that provide a quantitative description for the low charge state ejection phenomenon. Experimental conditions for the efficient discrimination against lower charge states are evaluated. Initial experimental observations reported are in agreement with the theoretical treatment.

Journal Article↗

Independent control of ion transmission in a jet disrupter dual-channel ion funnel electrospray ionization MS interface.

A new atmospheric pressure ionization mass spectrometer (API-MS) interface has been developed to allow the control of ion transmission through the first vacuum stage of the mass spectrometer. The described interface uses a dual-heated capillary and a dual-inlet ion funnel design. Two electrosprays, aligned with the dual-capillary inlet, are used to introduce ions from different solutions independently into the MS. The initial design was specifically aimed at developing a method for the controlled introduction of calibrant ions in highly accurate mass measurements using Fourier transform ion cyclotron resonance mass spectrometer (FTICR). The dual-channel ion funnel has different inlet diameters that are aligned with the dual capillaries. The large diameter main channel of the ion funnel is used for analyte introduction to provide optimum ion transmission. The second, smaller diameter channel inlet includes a jet disrupter in the ion funnel to modulate the ion transmission through the channel. The two inlet channels converge into a single-channel ion funnel where ions from both channels are mixed, focused, and transmitted to the mass analyzer. Both theoretical simulations and experimental results show that the transmission of different m/z species in the small diameter channel of the ion funnel can be effectively modulated by varying the bias voltage on the jet disrupter. Both static and dynamic modulations of ion transmission are demonstrated experimentally by applying either a constant DC or a square waveform voltage to the jet disrupter. High ion transmission efficiency, similar to the standard single-channel ion funnel, is maintained in the main analyte channel inlet of the ion funnel over a broad m/z range with negligible "cross talk" between the two ion funnel inlet channels. Several possible applications of the new interface (e.g., for high-accuracy MS analysis of complex biological samples) are described.

Calibration↗

Mass measurement errors caused by 'local" frequency perturbations in FTICR mass spectrometry.

One of the key qualities of mass spectrometric measurements for biomolecules is the mass measurement accuracy (MMA) obtained. FTICR presently provides the highest MMA over a broad m/z range. However, due to space charge effects, the achievable MMA crucially depends on the number of ions trapped in the ICR cell for a measurement. Thus, beyond some point, as the effective sensitivity and dynamic range of a measurement increase, MMA tends to decrease. While analyzing deviations from the commonly used calibration law in FTICR we have found systematic errors which are not accounted for by a "global" space charge correction approach. The analysis of these errors and their dependence on charge population and post-excite radius have led us to conclude that each ion cloud experiences a different interaction with other ion clouds. We propose a novel calibration function which is shown to provide an improvement in MMA for all the spectra studied.

Chemistry, Physical↗

Frequency shifts due to the interference of resolved peaks in magnitude-mode Fourier-transform ion cyclotron resonance mass spectra.

We have obtained relationships for frequency shifts resulting from the interference of spectral components for the magnitude mode Fourier transform. The approximation of a weak perturbation of well resolved peaks has been used. Both the low- and high-pressure limits for Fourier-transform ion cyclotron resonance (FTICR) operation have been considered. We have found that the shifts can be either negative or positive, depending on the initial phase and/or the choice of the time-domain interval. The magnitude of shifts generally does not exceed the peak width. In the approximation of small perturbations the shifts produced by multiple peaks are additive. We have compared theoretical results with experimental shifts for isotopic clusters of multiply charged insulin. Up to 1 ppm frequency variations were experimentally observed for the insulin 5+ charge state, consistent with theoretical estimates. The peak interference is of particular significance in the case of bio-molecular mass spectra having a large number of peaks and covering a considerable dynamic range (i.e., relative abundance). We conclude that the common mass measurement procedure based on the location of the magnitude mode maxima of well resolved peaks can result in systematic mass measurement errors. The relationships obtained provide corrections for the frequency shifts and thus improve the mass measurement accuracy.

Algorithms↗