PubMed Health⌕ Search

Biomedical subjects

Alicia J El Haj

Publications and source records attributed to Alicia J El Haj.

16 recordsLinked to original sources

Tissue engineering for tendon repair.

Tissue engineering aims to induce tissue self-regeneration in vivo or to produce a functional tissue replacement in vitro to be then implanted in the body. To produce a viable and functional tendon, a uniaxially orientated collagen type I matrix has to be generated. Biochemical and physical factors can potentially alter both the production and the organisation of this matrix, and their combination in a dose- and time-dependent manner is probably the key to in vitro engineered tendons. This review discusses the role of these different factors affecting tenocyte growth in a three-dimensional environment in vivo and in vitro, and underlines the future challenge of tendon tissue engineering.

Biocompatible Materials↗

VOCCs and TREK-1 ion channel expression in human tenocytes.

Mechanosensitive and voltage-gated ion channels are known to perform important roles in mechanotransduction in a number of connective tissues, including bone and muscle. It is hypothesized that voltage-gated and mechanosensitive ion channels also may play a key role in some or all initial responses of human tenocytes to mechanical stimulation. However, to date there has been no direct investigation of ion channel expression by human tenocytes. Human tenocytes were cultured from patellar tendon samples harvested from five patients undergoing routine total knee replacement surgery (mean age: 66 yr; range: 63-73 yr). RT-PCR, Western blotting, and whole cell electrophysiological studies were performed to investigate the expression of different classes of ion channels within tenocytes. Human tenocytes expressed mRNA and protein encoding voltage-operated calcium channel (VOCC) subunits (Ca alpha(1A), Ca alpha(1C), Ca alpha(1D), Ca alpha(2)delta(1)) and the mechanosensitive tandem pore domain potassium channel (2PK(+)) TREK-1. They exhibit whole cell currents consistent with the functional expression of these channels. In addition, other ionic currents were detected within tenocytes consistent with the expression of a diverse array of other ion channels. VOCCs and TREK channels have been implicated in mechanotransduction signaling pathways in numerous connective tissue cell types. These mechanisms may be present in human tenocytes. In addition, human tenocytes may express other channel currents. Ion channels may represent potential targets for the pharmacological management of chronic tendinopathies.

Aged↗

Expression of the mechanosensitive 2PK+ channel TREK-1 in human osteoblasts.

TREK-1 is a mechanosensitive member of the two-pore domain potassium channel family (2PK+) that is also sensitive to lipids, free fatty acids (including arachidonic acid), temperature, intracellular pH, and a range of clinically relevant compounds including volatile anaesthetics. TREK-1 is known to be expressed at high levels in excitable tissues, such as the nervous system, the heart and smooth muscle, where it is believed to play a prominent role in controlling resting cell membrane potential and electrical excitability. In this report, we use RT-PCR, Western blotting and immunohistochemistry to confirm that human derived osteoblasts and MG63 cells express TREK-1 mRNA and protein. In addition, we show gene expression of TREK2c and TRAAK channels. Furthermore, whole cell patch clamp electrophysiology demonstrates that these cells express a spontaneously active, outwardly rectifying potassium "background leak" current that shares many similarities to TREK-1. The outward current is largely insensitive to TEA and Ba2+, and is sensitive to application of lysophosphatidylcholine (LPC). In addition, blocking TREK-1 channel activity is shown to upregulate bone cell proliferation. It is concluded that human osteoblasts functionally express TREK-1 and that these channels contribute, at least in part, to the resting membrane potential of human osteoblast cells. We hypothesise a possible role for TREK-1 in mechanotransduction, leading to bone remodelling.

Adolescent↗

Using dihydropyridine-release strategies to enhance load effects in engineered human bone constructs.

We report on the development of a novel biodegradable scaffold capable of enhancing mechanical signals for tissue-engineering applications. It has been shown that mechanotransduction enhances bone formation in vitro and in vivo; in tissue-engineering applications, this phenomenon is exploited through the use of mechanical bioreactors to generate bone tissue. The dihydropyridine agonist Bay K8644 (Bay) acts to increase the opening time of mechanosensitive voltage-operated calcium channels (VOCCs), specifi- cally L-type VOCCs, which are known to play a fundamental role in the early mediation of mechanotransduction. We have produced porous 3-dimensional, Bay-encapsulated biodegradable poly(L-lactide) acid scaffolds using a solvent-casting and salt-leaching technique. The effects of the released Bay on osteoid production and mineralization in human bone cell-seeded constructs following incubation in a perfusion-compression bioreactor in vitro was investigated using Western blotting techniques and a calcium assay protocol developed in our lab. Our newly developed scaffolds act by slowly releasing the calcium channel agonist Bay K8644 as observed using ultraviolet spectroscopy, maintaining the open state of mechanosensitive VOCCs responding to load, which augments the load signal at sites of strain across the scaffold. Our results demonstrate that, in the presence of physiological loading regimes in vitro, release of Bay enhances collagen I protein production and osteoid calcification more than non-Bay control constructs do. Osteopontin and alpha2delta1 VOCC subunit protein levels were also higher as a result of perfusion-compression conditioning. These results indicate that Bay-encapsulated scaffolds can be used in the presence of load to enhance the production of load-bearing engineered tissue.

3-Pyridinecarboxylic acid, 1,4-dihydro-2,6-dimethy↗

Principles and design of a novel magnetic force mechanical conditioning bioreactor for tissue engineering, stem cell conditioning, and dynamic in vitro screening.

Mechanical conditioning of cells and tissue constructs in bioreactors is an important factor in determining the properties of tissue being produced. Mechanical conditioning within a bioreactor environment, however, has proven difficult. This paper presents the theoretical basis, design, and initial results of a mechanical conditioning system for cell and tissue culture which is based on biocompatible magnetic micro- and nanoparticles acting as a remote stress mechanism without invasion of the sterile bioreactor environment.

Bioreactors↗

Biodegradable scaffolds--delivery systems for cell therapies.

The use of cells as therapies for disease, repair and regeneration of tissues is one of the new challenges in modern therapeutics. To facilitate the ability to localise, condition and protect cells, biodegradable scaffolds are being developed that will improve the efficiency of these treatments. Thus, cell delivery systems, either scaffolds or capsules, play a pivotal role in the success of these techniques. This review discusses these novel approaches. The selection of scaffold materials is addressed alongside issues of biocompatibility. The current research developments in smart scaffolds, which focus on the formation of biomimetic scaffolds, new fabrication techniques capable of controlling architecture and microstructure of scaffolds, and the production of injectable and in situ crosslinked scaffolds, are outlined. Finally, the continuing challenges that will drive future research in the cell therapies are highlighted.

Animals↗

Characterizing the viscoelastic properties of thin hydrogel-based constructs for tissue engineering applications.

We present a novel indentation method for characterizing the viscoelastic properties of alginate and agarose hydrogel based constructs, which are often used as a model system of soft biological tissues. A sensitive long working distance microscope was used for measuring the time-dependent deformation of the thin circular hydrogel membranes under a constant load. The deformation of the constructs was measured laterally. The elastic modulus as a function of time can be determined by a large deformation theory based on Mooney-Rivlin elasticity. A viscoelastic theory, Zener model, was applied to correlate the time-dependent deformation of the constructs with various gel concentrations, and the creep parameters can therefore be quantitatively estimated. The value of Young's modulus was shown to increase in proportion with gel concentration. This finding is consistent with other publications. Our results also showed the great capability of using the technique to measure gels with incorporated corneal stromal cells. This study demonstrates a novel and convenient technique to measure mechanical properties of hydrogel in a non-destructive, online and real-time fashion. Thus this novel technique can become a valuable tool for soft tissue engineering.

Biocompatible Materials↗

On-line fluorescent monitoring of the degradation of polymeric scaffolds for tissue engineering.

Tissue engineering involves culturing, growing and assembling cells and newly generated matrix in polymeric scaffolds. To achieve a functional tissue in vitro, the cell-scaffold constructs are subjected to various stimulations during an incubation phase, which mimics the in vivo environment. In order to monitor the progression of tissue formation, there is a need for on-line and non-destructive methods of monitoring at the cellular and biomolecular level, for example, the assessment of scaffold degradation alongside the measure of matrix production. This study presents a proof of concept for monitoring scaffold degradation on-line within a culture environment. Using a mesoporous silica based approach, a pH sensitive fluorescent probe, fluorescein isothiocyanate (FITC), was incorporated into degradable polymeric scaffolds made from poly(L-lactic acid) which has a slow degradation rate, and poly(lactide-co-glycolide) which has a rapid degradation rate. The fluorescent probe was incorporated into thin films and three dimensional porous scaffolds demonstrating the capabilities of monitoring on-line. Following incubation, the intensity of fluorescence in the rapidly degrading scaffolds reduced with culture time in comparison to slow degrading polymeric scaffolds when observed qualitatively using fluorescent microscopy. The relationship between pH and fluorescent intensity was assessed, and the use of this technique for monitoring by-products via the solid scaffold by microscopy or through culture medium by a luminescence spectrometer is discussed. This study demonstrates that endowing scaffolds with a sensing element could provide an on-line and non-destructive monitoring method for tissue engineering.

Absorbable Implants↗

Study of tumor cell invasion by Fourier transform infrared microspectroscopy.

Lung cancer is usually fatal once it becomes metastatic. However, in order to develop metastases, a tumor usually invades the basal membrane and enters the vascular or lymphatic system. In this study, a three-dimensional artificial membrane using collagen type I, one of the main components of basal membranes, was established in order to investigate tumor cell invasion. Lung cancer cell line CALU-1 was seeded on this artificial membrane and cell invasion was studied using the Fourier transform infrared (FTIR) imaging technique. This approach allowed identification of tumor cells invading the collagen type I membrane by means of their infrared spectra and images. The mapping images obtained with FTIR microspectroscopy were validated with standard histological section analysis. The FTIR image produced using a single wavenumber at 1080 cm(-1), corresponding to PO2- groups in DNA from cells, correlated well with the histological section, which clearly revealed a cell layer and invading cells within the membrane. Furthermore, the peaks corresponding to amide A, I, and II in the spectra of the invading cells shifted compared to the noninvading cells, which may relate to the changes in conformation and/or heterogeneity in the phenotype of the cells. The data presented in this study demonstrate that FTIR microspectroscopy can be a fast and reliable technique to assess tumor invasion in vitro.

Carcinoma, Non-Small-Cell Lung↗

The influence of static magnetic fields on mechanosensitive ion channel activity in artificial liposomes.

The influence of static magnetic fields (SMFs) on the activity of recombinant mechanosensitive ion channels (the bacterial mechanosensitive ion channel of large conductance-MscL) following reconstitution into artificial liposomes has been investigated. Preliminary findings suggest that exposure to 80-mT SMFs does not induce spontaneous MscL activation in the absence of mechanical stimulation. However, SMFs do appear to influence the open probability and single channel kinetics of MscL exposed to negative pipette pressure. Typical responses include an overall reduction in channel activity or an increased likelihood of channels becoming "trapped open" in sub-conducting states following exposure to SMFs. There is a delay in the onset of this effect and it is maintained throughout exposure. Generally, channel activity showed slow or limited recovery following removal of the magnetic field and responses to the magnetic were often reduced or abolished upon subsequent exposures. Pre-exposure of the liposomes to SMFs resulted in reduced sensitivity of MscL to negative pipette pressure, with higher pressures required to activate the channels. Although the mechanisms of this effect are not clear, our initial observations appear to support previous work showing that the effects of SMFs on ion channels may be mediated by changes in membrane properties due to anisotropic diamagnetism of lipid molecules.

Anisotropy↗

Controlling cell biomechanics in orthopaedic tissue engineering and repair.

Tissue engineering offers an alternative approach with great potential for the treatment or replacement of damaged tissues or organs. In contrast to current treatments, a small sample of cells can be collected from the patient and cultured in vitro, greatly increasing the number of cells available for engineering tissue implants. As a result, engineered tissue implants limit the problems associated with patient trauma and undesirable immune response currently observed in surgical treatments practised in tissue and organ replacement. Mechano-transduction is known to play an essential role in bone tissue remodelling and repair. At physiological magnitudes, the effects of secondary messenger pathways, their components and local mediators generated as a direct result of mechanical load are known to result in an elevation of specific matrix protein mRNAs. Up-regulation of matrix protein production is paramount to tissue formation. Thus, mechano-transduction offers a method of producing bone tissue in vitro. However, successful transduction of mechanical stimuli from a substrate to cells is reliant upon a number of factors including cell-substrate adhesion, scaffold material mechanics and the activation of membrane channels, for example voltage-operated calcium channels (VOCC). Our research focuses on the optimisation of mechano-transduction pathways for successful bone tissue engineering. In this paper, we focus on the effects of cell-substrate adhesion, attenuation of VOCC activation states and biological conditioning of cell-scaffold constructs utilising bioreactors in relation to mechano-transduction-induced bone tissue production. The effects of these factors on successful bone tissue formation observed in increased matrix protein synthesis due to the optimisation of mechano-transduction pathways is discussed.

3-Pyridinecarboxylic acid, 1,4-dihydro-2,6-dimethy↗

Magnetic micro- and nanoparticle mediated activation of mechanosensitive ion channels.

Most cells are known to respond to mechanical cues, which initiate biochemical signalling pathways and play a role in cell membrane electrodynamics. These cues can be transduced either via direct activation of mechanosensitive (MS) ion channels or through deformation of the cell membrane and cytoskeleton. Investigation of the function and role of these ion channels is a fertile area of research and studies aimed at characterizing and understanding the mechanoactive regions of these channels and how they interact with the cytoskeleton are fundamental to discovering the specific role that mechanical cues play in cells. In this review, we will focus on novel techniques, which use magnetic micro- and nanoparticles coupled to external applied magnetic fields for activating and investigating MS ion channels and cytoskeletal mechanics.

Biomechanical Phenomena↗

Monitoring of lung tumour cell growth in artificial membranes.

Morbidity of many tumour types is associated with invasion of tumour cells through the basement membrane and subsequent metastasis to vital organs. Tumour invasion is frequently detected late on as many patients present with advanced disease. The method of detecting invasion is through conventional histological staining techniques, which are time consuming and require processing of the sample. This can affect interpretation of the results. In this study, a new imaging technique, optical coherence tomography (OCT), was used to monitor lung tumour cell growth in two artificial membranes composed of either collagen type I or Matrigel. In parallel, standard histological section analysis was performed to validate the accuracy of the monitoring by OCT. Cross-sectional images from OCT revealed that lung tumour cells infiltrated only when low cell seeding density (5 x 10(5)) and low collagen concentration (1.5 mg/ml) were combined. The cells could be easily differentiated from the artificial membranes and appeared as either a brighter layer on the top of the membrane or brighter foci embedded within the darker membrane. These cell-membrane morphologies matched remarkably to the standard histological section images. Our results suggest that OCT has a great potential to become a useful tool for fast and robust imaging of cell growth in vivo and as a potential assessment of cell invasion.

Cell Culture Techniques↗

Phosphorylcholine-containing polymers for use in cell encapsulation.

A model system for encapsulation of pancreatic islets which has potential properties for improving biocompatibility and immunosuppression was investigated. In vitro and in vivo studies have shown that phosphorylcholine-containing polymers have high biocompatibility due to low adsorption of proteins and reduced thrombus formation. Encapsulation of islets isolated from rats with a compound membrane composed of phosphorylcholine-containing polymers and cellulose acetate led to rapid insulin production and diffusion across the membrane in response to glucose challenge. The phosphorylcholine-containing polymer had a molecular weight of about 1.3 x 10(4) Da. The polymer-coated membrane excluded larger molecules such as IgG (molecular weight 150 kDa), thereby acting as a physical immuno-barrier, but allowed smaller molecules such as glucose and insulin to pass through.

Animals↗

Preliminary characterisation of mechanoresponsive regions of the c-fos promoter in bone cells.

Preliminary analysis of the mechanisms involved in induction of stretch-mediated transcriptional activity in the c-fos promoter of bone has been undertaken using a series of c-fos promoter-reporter constructs. UMR-106 osteoblastic cells transfected with reporter constructs were subjected to cyclical physiological loading. The major determinants in the resulting transcriptional mechanoactivation are within the sequence between -356 and -151 which contains the serum response element and a consensus shear stress response element. Elements beyond this region also play a role as deletion of this region does not eliminate mechanoinduction. These results suggest that the mechanical induction of c-fos in osteoblastic bone cells is mediated by multiple response elements.

Animals↗

Development of magnetic particle techniques for long-term culture of bone cells with intermittent mechanical activation.

Magnetic particles were coated with RGD and adhered to primary human osteoblasts. During a 21-day culture, the osteoblasts plus adhered magnetic particles underwent a daily exposure to a time-varying magnetic field via a permanent NdFeB magnet, thus applying a direct mechanical stress to the cells (Bmax approximately 60 mT). After 21 days, preliminary results show that the cells plus magnetic particles were viable and had proliferated. A von-kossa stain showed mineralized bone matrix produced at 21 days in the experimental group whereas the control groups showed no mineralized matrix production. Real-time reverse transcription-polymerase chain reaction at 21 days showed an upregulation of osteopontin from the experimental group in comparison to the control group of cells with adhered particles and no magnet applied. These preliminary results indicate that adherence of RGD-coated 4.5 microm ferromagnetic particles to primary human osteoblasts does not initiate cell necrosis up to 21 days in vitro. Also, mechanical stimulation of human osteoblasts by magnetic particle technology appears to have an influence on osteoblastic activity.

Cell Culture Techniques↗