Andreas Melzer

Publications and source records attributed to Andreas Melzer.

7 recordsLinked to original sources

Diagnostic performance of intraoperative in vivo hyperspectral imaging for meningioma grading and molecular alterations: results from a prospective feasibility study.

OBJECTIVE: Hyperspectral imaging (HSI) is an emerging intraoperative, noninvasive, contrast agent-free imaging modality that enables quantitative assessment of tissue composition. The present study aimed to investigate whether HSI-derived tissue parameters correlate with WHO grade and molecular markers of aggressiveness in cranial meningiomas. METHODS: In this prospective study, intraoperative in vivo HSI was performed using the TIVITA tissue system, capturing spectral signatures between 500 and 1000 nm. Quantitative tissue parameters included tissue oxygen saturation (StO2), near-infrared perfusion index, organ hemoglobin index (OHI), and tissue water index (TWI). HSI parameters were correlated with histopathological WHO grade and molecular alterations, including CDKN2A/B deletion, TERT promoter mutation, and 1p/22q loss. Group differences were analyzed using one-way ANOVA, and diagnostic performance was assessed using receiver operating characteristic (ROC) analysis. RESULTS: Forty-six meningiomas were included, comprising WHO grade 1 (n = 35) and WHO grade 2-3 (n = 11) tumors. TWI was significantly higher in WHO grade 2-3 meningiomas compared with WHO grade 1 tumors (mean 0.49 [SD 0.12] vs 0.38 [SD 0.17], p = 0.048). ROC analysis demonstrated an area under the ROC curve (AUC) of 0.71 (95% CI 0.56-0.86, p = 0.036) for TWI in discriminating higher-grade disease. A TWI cutoff ≥ 0.367 identified all WHO grade 2-3 meningiomas with 100% sensitivity and 100% negative predictive value. In a molecular subgroup (n = 15), OHI appeared higher in tumors with homozygous CDKN2A/B deletion than in nondeleted tumors (mean 0.77 [SD 0.04] vs 0.62 [SD 0.10]). However, only 3 CDKN2A/B-deleted cases were available, and these findings should be considered descriptive. ROC analysis yielded an AUC of 0.89 (95% CI 0.71-1.00). An OHI cutoff ≥ 0.712 identified all three CDKN2A/B-deleted tumors (100% sensitivity), with 83.3% specificity and 86.7% accuracy. CONCLUSIONS: The present investigation demonstrated that HSI-derived tissue water and hemoglobin metrics provide biologically meaningful information in meningiomas. Low tissue water content appeared to rule out higher-grade diseases in this first subset cohort, while elevated hemoglobin showed a potential association with CDKN2A/B deletion in a small exploratory subgroup. These findings support the potential of HSI as a real-time noninvasive tool for intraoperative risk stratification and should be evaluated in large-scale studies. German Clinical Trials Register no. DRKS00036771 (www.drks.de).

Humans↗

Testing methods for MR safety and compatibility of medical devices.

Magnetic resonance (MR) safety and image compatibility are important issues when using medical devices in the environment of magnetic resonance imaging (MRI). MR testing of medical devices is required for device approval by the FDA and the EU notified bodies. Testing methods have been established for basic issues and were published as first ASTM International standards (formerly ASTM, the American Society of Testing and Materials). Moreover, individual safety concerns such as the safe functioning of the device and the MR system are a necessity for medical devices within an MR environment. Standardized tests increase the safety of the patient and support both the MR user and the device manufacturers. This paper describes the state of the art of MR testing methods and requirements for medical devices.

Equipment Safety↗

Improvement of the MR imaging behavior of vascular implants.

Vascular implants can cause significant MR image artifacts due to the material (susceptibility artifact) or the electromagnetic characteristics (RF artifact). These artifacts are caused by the distortion of the magnetic field and interferences with the radio frequency (RF) waves of the MR imaging process. Void or complete vanishing of signals occurs in close proximity or inside implants. The artifacts can be minimized by using a material with low magnetic susceptibility and a design of the implant which avoids electrical conductive loops. But not all designs can be made loop-free and non conductive. A resonant circuit tuned to the Larmor frequency of the MR tomography overcomes the RF artifact and thus improves the visualization of the implant lumen. The paper reviews the state-of-the-art technology of the MR-signal improvement in implants lumen, with particular regard to the use of resonant circuits such as stents or Vena Cava Filter (VCF), with resonators in 1.0 Tesla and 1.5Tesla MRT.

Animals↗

Interventional robotic systems: applications and technology state-of-the-art.

Many different robotic systems have been developed for invasive medical procedures. In this article we will focus on robotic systems for image-guided interventions such as biopsy of suspicious lesions, interstitial tumor treatment, or needle placement for spinal blocks and neurolysis. Medical robotics is a young and evolving field and the ultimate role of these systems has yet to be determined. This paper presents four interventional robotics systems designed to work with MRI, CT, fluoroscopy, and ultrasound imaging devices. The details of each system are given along with any phantom, animal, or human trials. The systems include the AcuBot for active needle insertion under CT or fluoroscopy, the B-Rob systems for needle placement using CT or ultrasound, the INNOMOTION for MRI and CT interventions, and the MRBot for MRI procedures. Following these descriptions, the technology issues of image compatibility, registration, patient movement and respiration, force feedback, and control mode are briefly discussed. It is our belief that robotic systems will be an important part of future interventions, but more research and clinical trials are needed. The possibility of performing new clinical procedures that the human cannot achieve remains an ultimate goal for medical robotics. Engineers and physicians should work together to create and validate these systems for the benefits of patients everywhere.

Diagnostic Imaging↗

A vascular stent as an active component for locally enhanced magnetic resonance imaging: initial in vivo imaging results after catheter-guided placement in rabbits.

RATIONALE AND OBJECTIVE: A vascular stent constructed as a high frequency resonator improves the local signal-to-noise ratio at magnetic resonance (MR) imaging. After catheter placement and intravascular expansion, the stent can be used as an inductively coupled coil for MRI. The imaging properties of this balloon-expandable active MRI stent (AMRIS) were evaluated after x-ray fluoroscopy guided placement in the abdominal aorta of five rabbits using MR angiography (MRA) and flow measurements. METHODS: The AMRIS was implanted in the abdominal aorta of five rabbits using a balloon catheter inserted through the common carotid artery. The rabbits were examined by MRA (3D fast low-angle shot) at 1.5 tesla before and after intravenous injection of an iron-oxide-based blood pool contrast medium (dose 50 micro mol Fe/kg) and flow measurements (ECG-triggered phase contrast cine gradient-echo sequence). Signal-to-noise ratios (SNR) were calculated and flow volume curves were generated. The in-stent increase in temperature was measured in vitro using a fiberoptic thermometry system. RESULTS: The SNR was 5.0 +/- 0.6 outside the stent and 23.2 +/- 14.1 within the stent ( < 0.0 5) in plain MRA, 19.5 +/- 5.0 outside and 30.7 +/- 8.2 within the stent ( < 0.05) in contrast enhanced MRA, and 5.8 +/- 1.6 and 13.9 +/- 5.9, respectively ( < 0.05) in the magnitude images of the flow measurements. Flow volume curves within and distal to the stent were comparable. CONCLUSIONS: The expandable active MRI stent produces local signal enhancement in MRA and MR flow measurements after catheter placement and thus may improve assessment of the stented vessel segment by MR imaging.

Animals↗

An MRI-compatible surgical robot for precise radiological interventions.

OBJECTIVE: A variety of medical robots have been developed in recent years. MRI, including MR angiography and morphological imaging, with its excellent soft-tissue contrast is attractive for the development of interventional MRI-guided therapies and operations. This paper presents a telerobotic device for use in CT- and/or MR-guided radiological interventions. A robotic device for precise needle insertion during MR-guided therapy of spinal diseases will be briefly described. MATERIALS AND METHODS: Actuation of robots in an MRI environment is difficult due to the presence of strong magnetic fields. Therefore, the robot was constructed of nonmagnetic materials. The system frame was built from polyether ether ketone (PEEK) and fiber-reinforced epoxy, and actuated using ultrasonic and pneumatic motors. Completely MR-compatible sensors were developed for positioning control. RESULTS: Accuracy evaluation procedures and phantom tests were performed, with the required accuracy of approximately 1 mm being achieved and no significant artifacts being caused by the robotic device during MR image acquisition.

Animals↗