Monitoring lung edema using the pacemaker pulse and skin electrodes.

Previous clinical studies have shown that impedance measurements using right ventricular (RV) leads can monitor congestion due to heart failure. We previously reported on a three-fold advantage of bipolar left ventricular (LV) leads, which are near the lung, over RV leads in detecting pulmonary edema with impedance. A combined system of internal and external electrodes is now investigated using computer models, for use with conventional cardiac resynchronization (CRT) systems with unipolar LV leads. The system uses the normal LV pacing pulse as current source, and the resultant voltage at two skin electrodes to obtain a lung edema impedance (Z) measurement. Using gated MRIs, thoracic computer models of 3.8 million control volumes were constructed. Changes of Z with edema were simulated with a conventional totally implanted system, as well as with combined implanted-external systems. Right atrial (RA), RV, RV defibrillator coil and LV leads were used. Per cent Z responses to edema were compared. The all implanted responses were RA: 11.8%, RV: 8.6%, RVcoil: 11.3%, LV: 23.8%. The combined system responses were LV-ext: 21.45%, RA-ext: 10.13%, LV-arm leg: 26.08%. The computer models suggest that combined internal-external systems can be as sensitive as the totally implanted ones. Lung edema may be monitored at follow up or home for LV paced patients with only two external electrodes. Using very low impedance configurations optimized by computer can greatly maximize the response, with a cost of poor stability.

Body Constitution↗

Determinants of radial artery pulse wave analysis in asymptomatic individuals.

BACKGROUND: Noninvasive techniques to evaluate arterial stiffness include noninvasive radial artery pulse contour analysis. Diastolic pulse contour analysis provides a separate assessment of large (C1) and small artery (C2) elasticity. Analysis of the systolic pulse contour identifies two pressure peaks (P1 and P2) that relate to incident and reflected waves. This study aimed to compare indices from systolic and diastolic pulse contour analysis from the radial pressure waveform and to correlate these indices with traditional risk factors in asymptomatic individuals screened for cardiovascular disease. METHODS: In 298 consecutive subjects (206 male and 92 female healthy subjects with a mean age of 50 +/- 12 years), noninvasive radial artery pressure waveforms were acquired with a piezoelectric transducer and analyzed for 1) diastolic indices of C1 and C2 from the CR-2000 CVProfiler, and 2) systolic indices of augmentation as defined by augmentation pressure (AP), augmentation index (AIx), and systolic reflective index (SRI = P2/P1). These indices were then correlated to each other as well as to individual traditional risk factors and the Framingham Risk Score. RESULTS: Diastolic indices were significantly and inversely correlated to systolic indices with C2 showing a stronger inverse association than C1. C2 and Alx were significantly correlated with height, weight, and body mass index in men but not in women. All indices correlated better to blood pressure in women than men. In women, only systolic indices were significantly correlated to HDL cholesterol and only diastolic indices were significantly correlated to LDL cholesterol. All indices were significantly correlated to the Framingham Risk Score, which was stronger in women then men, but when adjusted for age only diastolic indices remained significant in women. CONCLUSIONS: Diastolic and systolic indices of pulse contour analysis correlate differently with traditional risk factors in men and women.

Adult↗

Cardiac resynchronization therapy optimization by finger plethysmography.

OBJECTIVES: We tested a simple noninvasive method for cardiac resynchronization therapy (CRT) optimization using standard finger photoplethysmography (FPPG). BACKGROUND: CRT can increase left ventricular cardiac output in patients with heart failure and ventricular conduction delay. Optimal therapy delivery depends on an appropriate AV delay. Multiple invasive and noninvasive methods have been attempted to identify patients and the best AV delay for CRT, but all suffer from a combination of high patient risk, cost, complexity, and low reproducibility. METHODS: FPPG and invasive aortic pressure data were simultaneously collected from 57 heart failure patients during intrinsic rhythm alternating with very brief periods of pacing at 4 to 5 AV delays. After correcting data for artifacts, the median percentage responses for each AV delay were classified as positive, negative, or neutral compared to baseline (Wilcoxon rank test). RESULTS: FPPG correctly identified positive aortic pulse pressure responses with 71% sensitivity (95% CI: 60-80%) and 90% specificity (95% CI: 84-94%) and negative aortic pulse pressure responses with 57% sensitivity (95% CI: 44-69%) and 96% specificity (95% CI: 91-98%). The magnitude of FPPG changes were strongly correlated with positive aortic pulse pressure changes (R(2) = 0.73, P < .0001) but less well correlated with negative aortic pulse pressure changes (R(2) = 0.43, P < .0001). FPPG selected 78% of the patients having positive aortic pulse pressure changes to CRT and identified the AV delay giving maximum aortic pulse pressure change in all selected patients. CONCLUSIONS: FPPG can provide a simple noninvasive method for identifying significant changes in aortic pulse pressure with high specificity, including identifying patients in whom aortic pulse pressure increases with CRT and the AV delay giving the maximum aortic pulse pressure.

Aorta↗

Improved lung edema monitoring with coronary vein pacing leads: a simulation study.

This computer simulation study compared the ability of left ventricular coronary vein (LV) pacemaker leads against right ventricular (RV) and right atrial (RA) leads to monitor lung edema using electrical impedance measurements. MRI images were used to construct electrical models of the thorax. Four lead configurations were tested with increases of pulmonary edema, intravascular fluids and heart dilation. The impedance changes observed at end systole with severe lung edema were 8.5%, 11.2%, 12.3% and 26.8% for the RA, RV, RV coil and LV configurations, respectively. Sensitivities in ohms per litre of lung fluid were 19.15, 19.15, 25.07 and 52.11 for the same configurations. The impedance changes for intravascular fluid overload with constant lung status were 1%, 1.3%, 9.2% and 6.4% while the sensitivities were 2, 2, 17 and 11 ohms per litre of intravascular fluid, respectively. Regional analysis of the thoracic sources of impedance revealed a high sensitivity near pacing electrodes and generator, and a low sensitivity to the right lung and all pulmonary vessels. Simulations showed that LV leads have a threefold advantage in sensitivity when monitoring lung edema in comparison to conventional RV leads. To monitor vascular and lung fluids independently, combined impedance configurations may be used. Regional sensitivities must be taken into account for proper clinical interpretation of impedance changes.

Cardiac Pacing, Artificial↗