Monitoring lung edema using the pacemaker pulse and skin electrodes.

Abstract

Previous clinical studies have shown that impedance measurements using right ventricular (RV) leads can monitor congestion due to heart failure. We previously reported on a three-fold advantage of bipolar left ventricular (LV) leads, which are near the lung, over RV leads in detecting pulmonary edema with impedance. A combined system of internal and external electrodes is now investigated using computer models, for use with conventional cardiac resynchronization (CRT) systems with unipolar LV leads. The system uses the normal LV pacing pulse as current source, and the resultant voltage at two skin electrodes to obtain a lung edema impedance (Z) measurement. Using gated MRIs, thoracic computer models of 3.8 million control volumes were constructed. Changes of Z with edema were simulated with a conventional totally implanted system, as well as with combined implanted-external systems. Right atrial (RA), RV, RV defibrillator coil and LV leads were used. Per cent Z responses to edema were compared. The all implanted responses were RA: 11.8%, RV: 8.6%, RVcoil: 11.3%, LV: 23.8%. The combined system responses were LV-ext: 21.45%, RA-ext: 10.13%, LV-arm leg: 26.08%. The computer models suggest that combined internal-external systems can be as sensitive as the totally implanted ones. Lung edema may be monitored at follow up or home for LV paced patients with only two external electrodes. Using very low impedance configurations optimized by computer can greatly maximize the response, with a cost of poor stability.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andres Belalcazar, Robert Patterson. 2005-03-29. Monitoring lung edema using the pacemaker pulse and skin electrodes.. https://doi.org/10.1088/0967-3334%2F26%2F2%2F015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology.

Patient and staff dose values in an interventional cardiology laboratory for different operational modes and several patient thicknesses (from 16 to 28 cm, simulated using polymethylmethacrylate) are presented. When increasing patient thicknesses and depending on fluoroscopy and cine modes, occupational doses can increase >30 times the baseline level. Scatter dose rates at the cardiologist's position with no radiation protective tools ranged from 1 to 14 mSv h(-1) for fluoroscopy, and from 10 to 47 mSv h(-1) during cine acquisition. Patient entrance surface air kerma rates increased by nearly 3 and staff dose rates by up to 2.6 when fluoroscopy was moved from the low to the high mode, for a typical 20 cm thickness. The respective increase factors were 6 and 4.2 when patient thickness rose from 16 to 28 cm, and by 10 and 8.3, when comparing cine acquisition with the low fluoroscopy mode. The knowledge of typical dose rates for each X-ray system in use in catheterisation laboratories is essential in order to optimise protection of patients and staff.

Body Constitution↗

Simulator-assisted setting of scan protocols for X-ray CT: development and clinical usefulness of the Scan Plan Simulator.

To assist in the selection of complicated computed tomography (CT) scan protocols and to obtain stable image SD values, prototype "Scan Plan Simulator" software with the following functions was developed and evaluated. 1) The image SD value that will be obtained in actual scanning is estimated by entering the patient's body size and scan protocol, after which a simulated image is displayed so that the estimated image SD value can be checked. The exposure dose can also be estimated in the Scan Plan Simulator. 2) The appropriate tube current is automatically set by entering the required image SD value. We evaluated the accuracy of the Scan Plan Simulator by comparing the simulation results with the image SD values and exposure dose obtained in actual scanning and assessed the usefulness of this method using Monte Carlo simulation based on body thickness data obtained in clinical examinations. The results showed that the Scan Plan Simulator not only stabilizes image SD by minimizing the effects of body size but also permits the exposure dose to be reduced by optimizing tube current.

Body Constitution↗