PubMed Health⌕ Search

Biomedical subjects

Angelo Zinellu

Publications and source records attributed to Angelo Zinellu.

At least 19 recordsLinked to original sources

Factors affecting S-homocysteinylation of LDL apoprotein B.

BACKGROUND: Hyperhomocysteinemia is an important risk factor for vascular disease and atherosclerosis, but the mechanisms by which homocysteine exerts its deleterious effects are not known. Because oxidation and/or homocysteinylation may increase atherogenicity of LDL, we investigated S-homocysteinylation of LDL as a possible contributor to atherosclerosis pathogenesis. METHODS: We used capillary electrophoresis to measure LDL-bound thiols [homocysteine, cysteine (Cys), cysteinylglycine, glutathione, and glutamylcysteine] in 104 healthy study participants We also assessed total plasma thiol concentrations and lipid profiles. RESULTS: Our data suggest that apoprotein B (apoB)-cysteinylglycine (CysGly), apoB-Hcy, and apoB-Cys concentrations are markedly higher in men than in women. The percentage of CysGly and glutathione on apoB was higher than that of the same thiols in plasma, whereas the other thiols were markedly less prevalent in lipoprotein than in plasma. Pearson correlation showed that among all thiols, only total plasma Hcy is related to apoB-Hcy concentrations. Multiple correlation analysis confirmed that total Hcy was the most important determinant of apoB-Hcy. Age and LDL cholesterol also showed positive associations, but Cys and, mainly, CysGly were negatively associated with apoB-Hcy concentrations. CONCLUSIONS: apoB-Hcy derivative formation is mainly dependent on total homocysteine concentration. Increased cholesterol concentrations are related to increased apoB-Hcy. CysGly seems to compete with Hcy for binding to LDL apoprotein, suggesting that CysGly may protect against atherosclerosis by decreasing the concentrations of Hcy transferred by LDL from plasma to endothelial and subendothelial spaces.

Adolescent↗

Pre-analytical factors affecting ascorbic and uric acid quantification in human plasma.

We have recently described a new capillary electrophoresis assay to measure serum ascorbic and uric acids in which a baseline separation of peaks was obtained in less than 4 min by using a 60.2 cm x 75 microm uncoated capillary with a 100 mmol/L sodium borate running buffer pH 8. Since during sample preparation AA is rapidly oxidized, we employed our new capillary electrophoresis method to analyze the pre-analytical factors affecting its stability. In particular we evaluated how the standard mix preparation, the blood collection (plasma EDTA or serum) and the plasma protein precipitation influence the results of analysis. Our data suggest that standard ascorbate must be dissolved in a solution containing cysteine and EDTA in order to avoid oxidation and that EDTA blood collection is better than serum for AA measurement. Moreover, the type and the quantity of the precipitating compound are critical parameters to obtain a complete recovery of analytes. We performed AA and UA analysis in 32 healthy volunteers with the optimized experimental conditions by using our capillary electrophoresis method and a reference CE assay. Obtained data were compared to Bland-Altman test to verify the accuracy of our CZE method.

Ascorbic Acid↗

Distribution of low-density lipoprotein-bound low-molecular-weight thiols: a new analytical approach.

We have recently demonstrated that low-density lipoprotein (LDL) apoprotein is able to bind the most concentrated plasma thiols such as cysteine, cysteinylglycine, and homocysteine by disulfide linkage. However, the LIF CE assay employed to measure linked thiols was not sensitive enough to verify whether low concentrated plasma thiols as glutathione and glutamylcysteine are also linked to apoprotein. By modifying sample treatment and electrophoretic parameters we set up a new method with an LOQ of about 1.5 nmol/L, by which we demonstrate that LDL apoprotein binds all physiological plasma thiols. The increased sensitivity was obtained by drying released apoB thiols after reduction treatment, dissolving them directly in a low volume of derivatization buffer and decreasing the dilution factor of derivatized sample before CE injection. Moreover, by increasing the concentration of the electrolyte buffer, we improved the selectivity of peaks, in particular between glutathione (GSH) and the impurity peak derived from unreacted 5-iodoacetamidofluorescein, which in the previous electrophoretic conditions were overlapped. The method optimization, reached by searching the best combination between sample matrix and CE run buffer, is fully described. Given the potential pathologic significance of protein thiolation, the proposed method may be useful to understand the mechanisms and the balances that regulate the interaction between thiols and -SH free groups of proteins.

Apolipoproteins B↗

Assay for the simultaneous determination of guanidinoacetic acid, creatinine and creatine in plasma and urine by capillary electrophoresis UV-detection.

Guanidinoacetic acid (GAA) measurement has recently become of great interest for the diagnosis of creatine (Cn) metabolism disorders, and research calls for rapid and inexpensive methods for its detection in plasma and urine in order to assess a large number of patients. We propose a new assay for the measurement of GAA by a simple CZE UV-detection without previous sample derivatization. Plasma samples were filtered by Microcon-10 microconcentrators and directly injected into the capillary, while for urine specimens a simple water dilution before injection was needed. A baseline separation was obtained in less than 8 min using a 60.2 cm x 75 microm uncoated silica capillary, 75 mmol/L Tris-phosphate buffer pH 2.25 at 15 degrees C. The performance of the developed method was assessed by measuring plasma creatinine and Cn in 32 normal subjects and comparing the data obtained by the new method with those found with the previous CE assay. Our new method seems to be an inexpensive, fast and specific tool to assess a large number of patients both in clinical and in research laboratories.

Creatine↗

Plasma homocysteine and cysteine levels in retinal vein occlusion.

PURPOSE: To determine plasma homocysteine and cysteine levels in patients with retinal vein occlusion (RVO) and in healthy subjects and to ascertain whether there are statistically significant differences between patients and control subjects. METHODS: In this case-control study, the study group consisted of 75 consecutive patients with RVO: 33 had central retinal vein occlusion (CRVO), and 42 had branch retinal vein occlusion (BRVO). Seventy-two apparently healthy age- and sex-matched subjects served as control subjects. Homocysteine and cysteine levels were measured with a new laser-induced fluorescence capillary electrophoresis (CE-LIF) METHOD: Wilcoxon or Student's t-test was used, when appropriate, to determine differences between groups. RESULTS: There were no significant differences in median plasma homocysteine between patients with RVO and control subjects, nor were there any statistically significant differences when patients were categorized by type of vein occlusion (CRVO or BRVO). Similarly, there were no significant differences in mean plasma cysteine between patients with RVO and control subjects. However, when categorized by type of vein occlusion, mean plasma cysteine was significantly higher in CRVO patients than in control subjects (P = 0.034). CONCLUSIONS: This study failed to demonstrate an association between increased plasma homocysteine and RVO. Mean plasma cysteine was significantly higher in patients with CRVO, suggesting that hypercysteinemia may contribute to the pathogenesis of this retinal vascular disorder.

Aged↗

Plasma creatinine and creatine quantification by capillary electrophoresis diode array detector.

Traditional clinical assays for nonprotein nitrogen compounds, such as creatine and creatinine, have focused on the use of enzymes or chemical reactions that allow measurement of each analyte separately. Most of these assays are mainly directed to urine quantification, so that their applicability on plasma samples is frequently hard to perform. This work describes a simple free zone capillary electrophoresis method for the simultaneous measurement of creatinine and creatine in human plasma. The effect of analytical parameters such as concentration and pH of Tris-phosphate running buffer and cartridge temperature on resolution, migration times, peak areas, and efficiency was investigated. Good separation was achieved using a 60.2-cm x 75-microm uncoated silica capillary, 75 mmol/L Tris-phosphate buffer, pH 2.25, at 15 degrees C, in less than 8 min. We compared the present method to a validated capillary electrophoresis assay, by measuring plasma creatinine in 120 normal subjects. The obtained data were compared by the Passing-Bablok regression and the Bland-Altman test. Moreover the performance of the developed method was assessed by measuring creatine and creatinine in 16 volunteers prior to and after a moderate physical exercise.

Adult↗

Separation of aceclofenac and diclofenac in human plasma by free zone capillary electrophoresis using N-methyl-D-glucamine as an effective electrolyte additive.

Aceclofenac (A) and diclofenac (D) are effective non-steroidal anti-inflammatory drugs (NSAIDs) derived from the phenylacetic acid with pronounced antirheumatic, anti-inflammatory, analgesic and antipyretic properties. Our work proposes a new, fast-free zone capillary electrophoresis method for the simultaneous determination of aceclofenac and diclofenac in human plasma. The effect of increasing concentrations of N-methyl-D-glucamine organic base on borate run buffer was investigated. A good separation was achieved using a 40 cm x 75 microm uncoated silica capillary, 300 mmol/l sodium borate buffer, 200 mmol/l N-methyl-D-glucamine, pH 8.9, in about 3 min. Moreover, the plasma sample pre-treatment procedure was examined: acidic precipitants such as trichloroacetic acid (TCA), metaphosphoric acid (MPA), perchloric acid (PCA) or 5-sulphosalicylic acid (SSA) cause a total loss of analytes while acetonitrile allows a recovery of 97-98% of both compounds. Its simplicity and rapidity and the low analysis costs demonstrate that our method is a reliable and efficient mean for the comprehensive determination of aceclofenac and diclofenac in human plasma when pharmacokinetics studies are required.

Adult↗

Thiol redox status evaluation in red blood cells by capillary electrophoresis-laser induced fluorescence detection.

Thiols and in particular glutathione (GSH) play a central role in human metabolism, including the detoxification of xenobiotics, cell homeostasis, radioprotection, and antioxidant defence. Here, a new method is provided for the measurement of reduced and total forms of thiols in red blood cells. In order to minimize oxidation of reduced thiols, a water erythrocyte lysis (15 min at 4 degrees C) was performed followed by a protein precipitation step with acetonitrile. The supernatant was rapidly derivatized with 5-iodoacetoamidefluorescein that trapped thiol groups, thus minimizing auto-oxidation. Derivatized samples were separated in a 57 cm x 75 microm ID capillary by using 5 mmol/L sodium phosphate, 4 mmol/L boric acid as electrolyte solution with 75 mmol/L N-methyl-D-glucamine at pH 11.0. Under these conditions, cysteinylglycine (CysGly), cysteine (Cys), glutathione, and gamma-glutamylcysteine (GluCys) were baseline-resolved in approximately 4 min. Precision tests showed a good repeatability of our method both for migration times (coefficient of variation CV < 0.8%) and areas (CV < 3.3%). Furthermore, a good reproducibility of intrassay and interassay tests was obtained (CV < 5% and CV < 8%, respectively). The method was employed to investigate the effect of acidic precipitation on intracellular thiol concentration. Our data suggest that sample acidification causes a modification of the measured redox thiol status due to the development of a pro-oxidant environment; moreover, the thiol redox status of red blood cells was evaluated in 22 healthy volunteers.

Electrophoresis, Capillary↗

Highly sensitive simultaneous detection of cultured cellular thiols by laser induced fluorescence-capillary electrophoresis.

We have recently described a new method to determine physiological thiols, in which the quantification of plasma homocysteine, cysteine, cysteinylglycine, glutathione, and glutamylcysteine was achieved after derivatization with 5-iodoacetamidofluorescein. Samples were separated and measured by capillary electrophoresis with laser-induced fluorescence in an uncoated fused-silica capillary, using a phosphate/borate run buffer and the organic base N-Methyl-D-glucamine as effective electrolyte addictive to obtain a baseline peak separation. In this paper, we propose an improvement of our method useful for the analysis of the intracellular thiols in different cultured cells. In particular, we studied run buffer and injection conditions in order to increase the sensitivity of the assay and we found that, by incrementing two times the injected volume and using the water plug before the sample injection, the sensitivity of our previous method was increased by about ten times. To maintain a good resolution between peaks, particularly between homocysteine and the internal standard d-penicillamine, we lengthened the run time by incrementing the concentration of the electrolyte buffer and the organic base d-glucamine and by decreasing the cartridge temperature from 40 to 25 degrees C. After these changes in electrophoretical parameters, cellular thiols were baseline-resolved in less than 14 min instead of 9 min as in our previous method, but the limit of quantification is increased from 50 to 1 nmol/L. This new procedure allows also to measure the intracellular thiols commonly found at low concentration, such as cysteinylglycine, glutamylcysteine, and homocysteine. The new analytical method performance was assessed by measuring the intracellular thiols in three different cell lines, i.e., HUVEC, ECV304, and R1 stem cells.

Animals↗

Sodium glycylglycine as effective electrolyte run buffer for ascorbic and uric acid separation by CZE: a comparison with two other CE assays.

A new CE method for ascorbic acid (AA) and uric acid (UA) detection in human plasma has been developed. Analytes were resolved in less than 4 min by employing sodium glycylglycine (Glygly) as electrolyte run buffer at pH 8.0. Using the diode array detector ability to measure multiple wavelengths simultaneously, detection was optimized by monitoring the run at 262 nm for AA and at 288 nm for UA. Electrophoretic parameters such as resolution, migration times, efficiency, and peak areas of this new method were compared to those obtained by the two CE assays described in literature, in which the analytes separation was achieved by using sodium borate (that allows faster migration times but poor resolution) or tricine (with the highest resolution but elevated migration times) as electrolyte run buffer. Sodium Glygly allows to obtain the same good resolution given by the tricine buffer but with the faster analysis times of the sodium borate run buffer. Ascorbate and urate levels were measured in 35 healthy volunteers by the three methods and the obtained data were compared by three different statistical tests (mountain plot, Passing-Bablok regression, and Bland-Altman test) in order to verify the accuracy of our proposed method.

Ascorbic Acid↗

Carotid narrowing degree and plasma thiol levels in carotid endarterectomy patients.

The aim of this work was to study the association between plasma thiol levels and percentage carotid narrowing in a group of 68 patients who underwent a carotid endarterectomy, pertained as a risk factor for vascular and cardiovascular disease. Total plasma thiols were measured by capillary electrophoresis laser-induced fluorescence. The mean values of the hematological parameters studied were within normal limits and 25% of the patients were hyperhomocysteinemic (homocysteine >15 micromol/L). Pearson's correlation between carotid narrowing degree and the most common risk factors for atherosclerosis showed a positive relationship only between carotid narrowing degree and cysteine levels (r=0.252; p<0.05). Stepwise multiple linear regression with carotid narrowing degree as the dependent variable, and cysteine, homocysteine, age, triglyceride and low-density lipoprotein-cholesterol as independent variables confirmed that cysteine was significantly associated with these variables. By regrouping the population according to cysteine and homocysteine concentration percentiles, we found positive correlation between these parameters and median values of carotid narrowing degree. Our study provides experimental evidence to confirm that plasma homocysteine and cysteine are involved in carotid narrowing after carotid endarterectomy intervention, suggesting that cysteine may be involved in the deleterious molecular mechanisms active in carotid stenosis.

Aged↗

The evaluation of the oxidative state of native-LDL: three methods compared.

LDL-oxidation is considered a contributing factor to the development of atherosclerotic lesions. However, to utilise the oxidative state of LDL as a marker of cardiovascular risk, reliable analytical methods for its detection must be defined. We have compared three methods for their capacity to evaluate the difference in the oxidation state of isolated LDL subjected to either dialysis (D-LDL) or gel filtration (F-LDL) to remove EDTA. Their susceptibility to oxidation promoted by Cu(2+) was monitored by following the time course of conjugated diene (CD) and lipid hydroperoxide (ROOH) accumulation. The relative electrophoretic mobility (REM) of the same LDL samples was evaluated by capillary electrophoresis. As measured by all three methods, F-LDL are less prone to oxidation than D-LDL when added with CuSO(4). REM of F-LDL and D-LDL significantly differs already before the addition of the metal catalyst, whereas CD and ROOH contents become significantly different only after it. Besides confirming that a rapid centrifugation followed by gel filtration is a more convenient procedure than dialysis to remove EDTA during LDL isolation, our study suggests the REM of isolated-LDL as the biochemical marker of choice in the evaluation of its oxidative state.

Cholesterol, LDL↗

Optimization of ascorbic and uric acid separation in human plasma by free zone capillary electrophoresis ultraviolet detection.

In this paper we propose a new fast free zone capillary electrophoresis method for the simultaneous determination of ascorbic acid (AA) and uric acid (UA) in human plasma. We investigated the effect of analytical parameters, such as concentration and pH of borate running buffer, cartridge temperature, and sample treatment, on resolution, migration times, corrected peak areas, and efficiency. A good separation was achieved using a 60.2-cmx75-microm uncoated silica capillary and 100 mmol/L sodium borate buffer, pH 8, when metaphosphoric acid was employed as protein precipitant, in less than 4 min. These conditions gave a good reproducibility of migration times (CV 0.35 and 0.34%) and peak areas (CV 3.2 and 3.1%) for ascorbate and urate, respectively. The limit of detection was 0.5mg/L for both analytes when the detection was performed at 254 nm for AA and at 292 nm for UA. We compared the present method with a validated capillary electrophoresis assay by measuring plasma urate and ascorbate in 32 normal subjects and the obtained data were analyzed by the Passing and Bablok regression.

Ascorbic Acid↗

Plasma D-penicillamine redox state evaluation by capillary electrophoresis with laser-induced fluorescence.

D-Penicillamine (D-Pen) is a thiol drug used in the treatment of Wilson's disease, rheumatoid arthritis, metal intoxication and cystinuria. We have recently described a new capillary electrophoresis (CE) method to measure physiological thiols, in which separation of total plasma homocysteine, cysteine, cysteinylglycine, glutathione is achieved using the organic base N-methyl-D-glucamine in the run buffer. In this paper, we present an improvement of our method that allows a baseline separation of total plasma D-Pen from the physiological thiols. Moreover, reduced, free and protein-bound forms of drug are measured by varying the order of disulfide reduction with tributylphosphine and proteins precipitation with 5-sulphosalicylic acid (SSA). After derivatization with 5-iodoacetamidofluorescein (5-IAF), samples are separated and measured by capillary electrophoresis with laser-induced fluorescence in an uncoated fused-silica capillary (57 x 75 microm i.d.) using a phosphate/borate run buffer pH 11.4. In these conditions, the migration time of D-Pen is about 7 min and the time required for each analysis is roughly 10 min. The proposed method has been utilized to measure the various forms of the drug in a D-Pen administered Wilson's disease patient.

Fluorescence↗

A new HPLC method for serum neopterin measurement and relationships with plasma thiols levels in healthy subjects.

Neopterin, a pyrazinopyrimidine compound, serves as a marker of cellular immune system activation, and it can be used as a prognostic predictor for certain types of diseases. We propose a new simple HPLC method to measure serum neopterin with highly sensitive fluorimetric detection. After TCA serum protein precipitation, the supernatant was diluted five times, injected into a C18 reversed-phase column and eluted at a flow rate of 1.5 mL/min by an isocratic water-acetonitrile (99:1) mobile phase. The natural fluorescence of the molecule was detected at excitation wavelength 353 nm and emission 438 nm. In these conditions the neopterin retention time was about 4 min. Our proposed method was compared with a validated chromatographic separation, and the obtained data of the serum neopterin from 35 healthy volunteers were analysed by Passing-Bablok regression and Bland-Altman test. Neopterin measurement in healthy subjects was also employed to investigate on its potential relationships with plasma thiols levels.

Adult↗