PubMed Health⌕ Search

Biomedical subjects

Angelo Zinellu

Publications and source records attributed to Angelo Zinellu.

23 records · Page 2Linked to original sources

Plasma thiols redox status by laser-induced fluorescence capillary electrophoresis.

High concentrations of total plasma thiols such as cysteine and homocysteine are important risk factors for atherosclerosis and cardiovascular diseases. We have recently described a new laser-induced fluorescence capillary electrophoresis (CE-LIF) method to measure total plasma thiols, in which the baseline separation of cysteinylglycine, homocysteine, cysteine, and glutathione was achieved by adding the organic base N-methyl-D-glucamine to the run buffer. However, because the active fractions of homocysteine and cysteine responsible for vascular injuries are still unknown, research calls for a set up of methods able to analyze different forms of plasma thiols. In this paper, we present an improvement of our previous method that allows the measurement of different thiol forms. Total, reduced, and free thiols were measured by varying the order of disulfide reduction with tributylphosphine and proteins precipitation with 5-sulfosalicylic acid. After derivatization with 5-iodoacetamidofluorescein, samples were separated and measured by CE-LIF using a phosphate/borate buffer in the presence of 75 mmol/L N-methyl-D-glucamine. Oxidized thiols and protein bound thiols were calculated by difference, free minus reduced and total minus free form, respectively. Linearity, reproducibility, analytical recovery, and sensitivity were evaluated. The assay was used to measure the thiols redox status in 15 plasma samples from healthy volunteers.

Electrophoresis, Capillary↗

Determination of creatinine in human serum by short-end injection capillary zone electrophoresis.

A new ultra-rapid free-solution capillary zone electrophoresis method to measure serum creatinine is presented. Procedural parameters such as injection mode, concentration and pH of phosphate running buffer and acidic deproteinization of serum samples were investigated. Short-end injection permits a decrease of the analysis time by injecting samples at the outlet end of a silica capillary closest to the detection window, so reducing the migration distance. Thus, when a capillary with an effective length of 10.2 cm and a 40 mmol/L sodium phosphate buffer pH 2.35 was used, the obtained migration time of the creatinine peak was the shortest never described before, about 1.1 min. These conditions give a good reproducibility of the migration times (coefficient of variation, CV% < 0.5) and the peak areas (CV% < 2.8). Intra- and interassay CV were 3.06 and 6.26%, respectively, and analytical recovery was 99.4%. We compared our proposed method to Jaffé colorimetric assay, by measuring serum creatinine in 128 normal subjects. The obtained data were analyzed by the Passing and Bablok regression and Bland-Altman test. Creatinine concentration in healthy subjects was also used to investigate on its relationships with plasma thiols levels.

Creatinine↗

Optimization of the principal parameters for the ultrarapid electrophoretic separation of reduced and oxidized glutathione by capillary electrophoresis.

Several factors can influence the analytical efficiency and rapidity of the quantitative determination of erythrocyte glutathione by capillary zone electrophoresis (CZE). We optimized the time, efficiency and resolution of the electrophoretic separation of reduced (GSH) and oxidized (GSSG) glutathione by studying the influence of the most important factors affecting the separation, i.e. the pH and ionic strength of the electrolyte solution, the capillary length and temperature. Best results in the shortest time are obtained at 25 degrees C, using an uncoated 37 cm x 75 microm i.d. capillary and a 300 mmol/l borate buffer pH 7.8. These conditions give a good reproducibility of the corrected peak areas (R.S.D. 1.41 and 1.31%) and of the migration time (R.S.D. 0.22 and 0.26%) for GSH and GSSG, respectively. The high concentration buffer, besides permitting a good resolution of standard GSH and GSSG mix, allows also N-nitrosoglutathione detection. By shortening the capillary length to 27 cm, the separation time of GSH and GSSG can be further decreased to less than 60s. This shortened method, the most rapid described in literature, can detect and quantify GSH in red blood cells despite a loss of sensitivity. To compare the new method here described with the Beutler colorimetric method, the data relative to the GSH content of red blood cells from young normal subjects were analyzed by the Passing and Bablok regression and the Bland-Altman test.

Electrophoresis, Capillary↗

N-methyl-D-glucamine improves the laser-induced fluorescence capillary electrophoresis performance in the total plasma thiols measurement.

We describe an ultrarapid capillary electrophoresis with laser-induced fluorescence (CE-LIF) method for total plasma thiols measurement. Reduced thiols by 10% tri-n-butylphosphine (TBP) were derivatized in 10 min at room temperature with 5-iodoacetamidofluorescein (5-IAF) as fluorescent reagent. We show that CE-LIF allows a baseline separation of total plasma cysteinylglycine, homocysteine, cysteine, and glutathione in less than 5 min when N-methyl-D-glucamine in run buffer was added. CE was compared with high-performance liquid chromatography (HPLC) with fluorescence detection. The Bland-Altman test and Passing-Bablok regression demonstrates that the results obtained by CE-LIF and by HPLC are highly comparable. The simplified procedure of sample preparation, the short incubation and fast separation times, the high specificity, sensitivity and reproducibility, and the lower cost of analysis suggest that our proposed method can be considered valuable for the automation analysis in a routine laboratory.

Adult↗

Ultrarapid capillary electrophoresis method for the determination of reduced and oxidized glutathione in red blood cells.

We describe a very rapid high-performance capillary electrophoresis method for the separation and quantification of reduced (GSH) and oxidized (GSSG) glutathione in red blood cells. Two procedures for sample preparation have been compared, Microcon-10 membrane filtration and acid precipitation. The separation is obtained in an uncoated capillary using a high ionic strength borate buffer at pH 7.8. The intra-assay coefficients of variation (CVs%) are 1.53 and 1.66 for GSH and GSSG, respectively. The run is shorter than 90 s and the migration time is highly reproducible both for GSH (CV% 0.22) and GSSG (CV% 0.17). When the filtration step is used only GSH is found, whereas both GSH and GSSG are detectable after acid precipitation, suggesting that GSSG revealed after acid treatment may be an artefact due to GSH oxidation. Because of its good analytical performance this method could be used for routine red blood cell glutathione measurement in healthy or pathological conditions.

Electrophoresis, Capillary↗