Digimouse: a 3D whole body mouse atlas from CT and cryosection data.

We have constructed a three-dimensional (3D) whole body mouse atlas from coregistered x-ray CT and cryosection data of a normal nude male mouse. High quality PET, x-ray CT and cryosection images were acquired post mortem from a single mouse placed in a stereotactic frame with fiducial markers visible in all three modalities. The image data were coregistered to a common coordinate system using the fiducials and resampled to an isotropic 0.1 mm voxel size. Using interactive editing tools we segmented and labelled whole brain, cerebrum, cerebellum, olfactory bulbs, striatum, medulla, masseter muscles, eyes, lachrymal glands, heart, lungs, liver, stomach, spleen, pancreas, adrenal glands, kidneys, testes, bladder, skeleton and skin surface. The final atlas consists of the 3D volume, in which the voxels are labelled to define the anatomical structures listed above, with coregistered PET, x-ray CT and cryosection images. To illustrate use of the atlas we include simulations of 3D bioluminescence and PET image reconstruction. Optical scatter and absorption values are assigned to each organ to simulate realistic photon transport within the animal for bioluminescence imaging. Similarly, 511 keV photon attenuation values are assigned to each structure in the atlas to simulate realistic photon attenuation in PET. The Digimouse atlas and data are available at http://neuroimage.usc.edu/Digimouse.html.

Anatomy, Cross-Sectional↗

Effect of optical property estimation accuracy on tomographic bioluminescence imaging: simulation of a combined optical-PET (OPET) system.

Inevitable discrepancies between the mouse tissue optical properties assumed by an experimenter and the actual physiological values may affect the tomographic localization of bioluminescent sources. In a previous work, the simplifying assumption of optically homogeneous tissues led to inaccurate localization of deep sources. Improved results may be obtained if a mouse anatomical map is provided by a high-resolution imaging modality and optical properties are assigned to segmented tissues. In this work, the feasibility of this approach was explored by simulating the effect of different magnitude optical property errors on the image formation process of a combined optical-PET system. Some comparisons were made with corresponding simulations using higher spatial resolution data that are typically attainable by CCD cameras. In addition, simulation results provided insights on some of the experimental conditions that could lead to poor localization of bioluminescent sources. They also provided a rough guide on how accurately tissue optical properties need to be known in order to achieve correct localization of point sources with increasing tissue depth under low background noise conditions.

Animals↗

A method of image registration for small animal, multi-modality imaging.

Many research institutions have a full suite of preclinical tomographic scanners to answer biomedical questions in vivo. Routine multi-modality imaging requires robust registration of images generated by various tomographs. We have implemented a hardware registration method for preclinical imaging that is similar to that used in the combined positron emission tomography (PET)/computed tomography (CT) scanners in the clinic. We designed an imaging chamber which can be rigidly and reproducibly mounted on separate microPET and microCT scanners. We have also designed a three-dimensional grid phantom with 1288 lines that is used to generate the spatial transformation matrix from software registration using a 15-parameter perspective model. The imaging chamber works in combination with the registration phantom synergistically to achieve the image registration goal. We verified that the average registration error between two imaging modalities is 0.335 mm using an in vivo mouse bone scan. This paper also estimates the impact of image misalignment on PET quantitation using attenuation corrections generated from misregistered images. Our technique is expected to produce PET quantitation errors of less than 5%. The methods presented are robust and appropriate for routine use in high throughput animal imaging facilities.

Animals↗

Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom.

The purpose of this work was to calculate radiation dose and its organ distribution in a realistic mouse phantom from micro-computed tomography (microCT) imaging protocols. CT dose was calculated using GATE and a voxelized, realistic phantom. The x-ray photon energy spectra used in simulations were precalculated with GATE and validated against previously published data. The number of photons required per simulated experiments was determined by direct exposure measurements. Simulated experiments were performed for three types of beams and two types of mouse beds. Dose-volume histograms and dose percentiles were calculated for each organ. For a typical microCT screening examination with a reconstruction voxel size of 200 microm, the average whole body dose varied from 80 mGy (at 80 kVp) to 160 mGy (at 50 kVp), showing a strong dependence on beam hardness. The average dose to the bone marrow is close to the soft tissue average. However, due to dose nonuniformity and higher radiation sensitivity, 5% of the marrow would receive an effective dose about four times higher than the average. If CT is performed longitudinally, a significant radiation dose can be given. The total absorbed radiation dose is a function of milliamperes-second, beam hardness, and desired image quality (resolution, noise and contrast). To reduce dose, it would be advisable to use the hardest beam possible while maintaining an acceptable contrast in the image.

Animals↗

Noninvasive measurement of cardiovascular function in mice with high-temporal-resolution small-animal PET.

UNLABELLED: The aim of this study was to explore the feasibility of determining parameters of cardiovascular function in mice noninvasively by high-temporal-resolution imaging with a dedicated small-animal PET system. METHODS: Twenty-five anesthetized mice (28.8 +/- 4.6 g) were injected via an intravenous catheter with a 30-microL bolus of (18)F-FDG (8-44 MBq). The first 9 s of data were reconstructed into 30 frames of 0.3 s using filtered backprojection. The time-activity curve derived from a left ventricle volume of interest was corrected for tracer recirculation and partial volume. Cardiac output was calculated by the Stewart-Hamilton method, in which cardiac output is total injected activity divided by the area under the left ventricle time-activity curve. Cardiac output divided by body weight was defined as cardiac index; cardiac output divided by heart rate yielded the stroke volume. In 5 mice, measurements were repeated 2-4 times to assess reproducibility. In 4 mice, the hemodynamic response to dobutamine was examined by measuring heart rate, cardiac output, and stroke volume. RESULTS: The cardiac output averaged 20.4 +/- 3.4 mL/min; in the repeated measurements, the parameter displayed a mean percentage SD per mouse of 10% +/- 6%. The cardiac index averaged 0.73 +/- 0.19 mL/min/g and the stroke volume 45.0 +/- 6.9 microL, and both correlated with heart rate (r = 0.53, P = 0.007, and r = 0.49, P = 0.01, respectively). During dobutamine stress, heart rate increased from 423 +/- 50 to 603 +/- 30 beats/min (P = 0.002) and cardiac output increased from 18.5 +/- 1.9 to 32.0 +/- 4.2 mL/min (P = 0.008). CONCLUSION: Parameters of cardiovascular function can be measured in mice noninvasively by radionuclide angiography using high-temporal-resolution small-animal PET. Measured values of cardiac output and stroke volume are reproducible and comparable to those obtained with MRI. The approach permits the monitoring of changes in cardiovascular function in response to pharmacologic intervention.

Animals↗

Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study.

The feasibility and limits in performing tomographic bioluminescence imaging with a combined optical-PET (OPET) system were explored by simulating its image formation process. A micro-MRI based virtual mouse phantom was assigned appropriate tissue optical properties to each of its segmented internal organs at wavelengths spanning the emission spectrum of the firefly luciferase at 37 degrees C. The TOAST finite-element code was employed to simulate the diffuse transport of photons emitted from bioluminescence sources in the mouse. OPET measurements were simulated for single-point, two-point and distributed bioluminescence sources located in different organs such as the liver, the kidneys and the gut. An expectation maximization code was employed to recover the intensity and location of these simulated sources. It was found that spectrally resolved measurements were necessary in order to perform tomographic bioluminescence imaging. The true location of emission sources could be recovered if the mouse background optical properties were known a priori. The assumption of a homogeneous optical property background proved inadequate for describing photon transport in optically heterogeneous tissues and led to inaccurate source localization in the reconstructed images. The simulation results pointed out specific methodological challenges that need to be addressed before a practical implementation of OPET-based bioluminescence tomography is achieved.

Computer Simulation↗

Attenuation correction for small animal PET tomographs.

Attenuation correction is one of the important corrections required for quantitative positron emission tomography (PET). This work will compare the quantitative accuracy of attenuation correction using a simple global scale factor with traditional transmission-based methods acquired either with a small animal PET or a small animal x-ray computed tomography (CT) scanner. Two phantoms (one mouse-sized and one rat-sized) and two animal subjects (one mouse and one rat) were scanned in CTI Concorde Microsystem's microPET Focus for emission and transmission data and in ImTek's MicroCAT II for transmission data. PET emission image values were calibrated against a scintillation well counter. Results indicate that the scale factor method of attenuation correction places the average measured activity concentration about the expected value, without correcting for the cupping artefact from attenuation. Noise analysis in the phantom studies with the PET-based method shows that noise in the transmission data increases the noise in the corrected emission data. The CT-based method was accurate and delivered low-noise images suitable for both PET data correction and PET tracer localization.

Algorithms↗

Tailoring the pharmacokinetics and positron emission tomography imaging properties of anti-carcinoembryonic antigen single-chain Fv-Fc antibody fragments.

Antibody fragments are recognized as promising vehicles for delivery of imaging and therapeutic agents to tumor sites in vivo. The serum persistence of IgG1 and fragments with intact Fc region is controlled by the protective neonatal Fc receptor (FcRn) receptor. To modulate the half-life of engineered antibodies, we have mutated the Fc-FcRn binding site of chimeric anti-carcinoembryonic antigen (CEA) antibodies produced in a single-chain Fv-Fc format. The anti-CEA T84.66 single-chain Fv-Fc format wild-type and five mutants (I253A, H310A, H435Q, H435R, and H310A/H435Q, Kabat numbering system) expressed well in mammalian cell culture. After purification and characterization, effective in vitro antigen binding was shown by competition ELISA. Biodistribution studies in BALB/c mice using (125)I- and (131)I-labeled fragments revealed blood clearance rates from slowest to fastest as follows: wild-type > H435R > H435Q > I253A > H310A > H310A/H435Q. The terminal half-lives of the mutants ranged from 83.4 to 7.96 hours, whereas that of the wild-type was approximately 12 days. Additionally, (124)I-labeled wild-type, H435Q, I253A, H310A, and H310A/H435Q variants were evaluated in LS174T xenografted athymic mice by small animal positron emission tomography imaging, revealing localization to the CEA-positive xenografts. The slow clearing wild-type and H435Q constructs required longer to localize to the tumor and clear from the circulation. The I253A and H310A fragments showed intermediate behavior, whereas the H310A/H435Q variant quickly localized to the tumor site, rapidly cleared from the animal circulation and produced clear images. Thus, attenuating the Fc-FcRn interaction provides a way of controlling the antibody fragment serum half-life without compromising expression and tumor targeting.

Animals↗

Instrumentation for molecular imaging in preclinical research: Micro-PET and Micro-SPECT.

Noninvasive imaging of molecular events and interactions in living small animal models has gained increasing importance in preclinical research. Two of the imaging modalities available for this research with potential for translation to the clinic are dedicated small animal positron emission tomography and single-photon emission computed tomography. This brief review introduces the fundamental principles behind these imaging technologies and instrumentation, and discusses the limitations in terms of their spatial resolution and sensitivity. In addition, it provides a perspective regarding the research and commercial development of these systems and presents examples of biological applications. Finally, it discusses the major challenges facing these technologies, advantages and limitations with respect to other technologies, and some future prospects.

Animals↗

Investigation of OPET Performance Using GATE, a Geant4-Based Simulation Software.

A combined optical positron emission tomography (OPET) system is capable of both optical and PET imaging in the same setting, and it can provide information/interpretation not possible in single-mode imaging. The scintillator array here serves the dual function of coupling the optical signal from bioluminescence/fluorescence to the photodetector and also of channeling optical scintillations from the gamma rays. We report simulation results of the PET part of OPET using GATE, a Geant4 simulation package. The purpose of this investigation is the definition of the geometric parameters of the OPET tomograph. OPET is composed of six detector blocks arranged in a hexagonal ring-shaped pattern with an inner radius of 15.6 mm. Each detector consists of a two-dimensional array of 8 × 8 scintillator crystals each measuring 2 × 2 × 10 mm(3). Monte Carlo simulations were performed using the GATE software to measure absolute sensitivity, depth of interaction, and spatial resolution for two ring configurations, with and without gantry rotations, two crystal materials, and several crystal lengths. Images were reconstructed with filtered backprojection after angular interleaving and transverse one-dimensional interpolation of the sinogram. We report absolute sensitivities nearly seven times that of the prototype microPET at the center of field of view and 2.0 mm tangential and 2.3 mm radial resolutions with gantry rotations up to an 8.0 mm radial offset. These performance parameters indicate that the imaging spatial resolution and sensitivity of the OPET system will be suitable for high-resolution and high-sensitivity small-animal PET imaging.

Journal Article↗

Nitrogen-13 ammonia cardiac positron emission tomography in mice: effects of clonidine-induced changes in cardiac work on myocardial perfusion.

We explored the feasibility of imaging myocardial perfusion and of demonstrating the flow changes in response to reduction of cardiac work non-invasively in anesthetized mice using high spatial resolution, dedicated small-animal positron emission tomography (microPET). In 31 C57BL/6 mice anesthetized with pentobarbital or isoflurane, (13)N-ammonia was injected intravenously and images were recorded with microPET from 4 to 20 min. Fifteen mice (group 1) were studied consecutively at baseline (BL) and after reduction of heart rate (HR) with intraperitoneal injection of clonidine (CLN) to investigate effects of CLN-induced reduction of cardiac work on myocardial (13)N-ammonia uptake. Eight mice (group 2) were imaged repeatedly at BL and eight mice (group 3) twice after CLN to examine reproducibility. Total myocardial (13)N-ammonia accumulation was determined from the transaxial images and normalized for injected dose (%ID). HR was 412+/-97 beats/min at BL and 212+/-44 beats/min after CLN (P<0.0001). In group 1, the %ID significantly decreased from 1.50%+/-0.27% at BL to 1.29%+/-0.28% after CLN (P<0.0001). In groups 2 and 3, reproducibility of %ID was good (y=0.96x+0.105, SEE=0.212%, r(2)=0.749, P<0.0001). In conclusion, (13)N-ammonia microPET imaging demonstrated non-invasively a reduction of myocardial perfusion induced by clonidine in mice. We believe this study is of importance as the first report on myocardial perfusion imaging and flow validation in in vivo mouse hearts with a left ventricular size of only 5 mm using (13)N-ammonia and PET. MicroPET will aid in elucidating cardiac pathophysiology in transgenic mice and monitoring effects of gene therapies on myocardial perfusion.

Ammonia↗

MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.

MicroPET II is a second-generation animal PET scanner designed for high-resolution imaging of small laboratory rodents. The system consists of 90 scintillation detector modules arranged in three contiguous axial rings with a ring diameter of 16.0 cm and an axial length of 4.9 cm. Each detector module consists of a 14 x 14 array of lutetium oxyorthosilicate (LSO) crystals coupled to a multi-channel photomultiplier tube (MC-PMT) through a coherent optical fibre bundle. Each LSO crystal element measures 0.975 mm x 0.975 mm in cross section by 12.5 mm in length. A barium sulphate reflector material was used between LSO elements leading to a detector pitch of 1.15 mm in both axial and transverse directions. Fused optical fibre bundles were made from 90 microm diameter glass fibres with a numerical aperture of 0.56. Interstitial extramural absorber was added between the fibres to reduce optical cross talk. A charge-division readout circuit was implemented on printed circuit boards to decode the 196 crystals in each array from the outputs of the 64 anode signals of the MC-PMT. Electronics from Concorde Microsystems Inc. (Knoxville, TN) were used for signal amplification, digitization, event qualification, coincidence processing and data capture. Coincidence data were passed to a host PC that recorded events in list mode. Following acquisition, data were sorted into sinograms and reconstructed using Fourier rebinning and filtered hackprojection algorithms. Basic evaluation of the system has been completed. The absolute sensitivity of the microPET II scanner was 2.26% at the centre of the field of view (CFOV) for an energy window of 250-750 keV and a timing window of 10 ns. The intrinsic spatial resolution of the detectors in the system averaged 1.21 mm full width at half maximum (FWHM) when measured with a 22Na point source 0.5 mm in diameter. Reconstructed image resolution ranged from 0.83 mm FWHM at the CFOV to 1.47 mm FWHM in the radial direction, 1.17 mm FWHM in the tangential direction and 1.42 mm FWHM in the axial direction at 1 cm offset from the CFOV. These values represent highly significant improvements over our earlier microPET scanner (approximately fourfold sensitivity increase and 25-35% improvement in linear spatial resolution under equivalent operating conditions) and are expected to be further improved when the system is fully optimized.

Animals↗

Positron-emission tomography reporter gene expression imaging in rat myocardium.

BACKGROUND: This study examines the quantitative accuracy, detection sensitivity, and time course of imaging the expression of a mutant herpes simplex type-1 virus thymidine kinase (HSV1-sr39tk) PET reporter gene in rat myocardium by using the PET reporter probe 9-(4-[18F]-Fluoro-3-Hydroxymethylbutyl)-Guanine ([18F]-FHBG) and a small-animal PET (microPET). METHODS AND RESULTS: In 40 rats, adenovirus expressing HSV1-sr39tk driven by a cytomegalovirus promoter (Ad-CMV-HSV1-sr39tk, 1x10(6) to 1x10(9) pfu) was injected through a thoracotomy directly into the left ventricular myocardium. After 3 days, myocardial perfusion was imaged with [13N]-ammonia for delineating the left ventricular myocardium, followed by imaging the expression of the reporter gene with intravenous [18F]-FHBG. The total myocardial [18F]-FHBG accumulation was quantified in percent of injected dose (%ID). Immunohistochemistry and autoradiography demonstrated HSV1-sr39tk enzyme (HSV1-sr39TK) and accumulation of [18F]-FHBG in the inoculated myocardium in 3 rats each. In 24 rats with various viral titers, the %ID was correlated with ex vivo well counting (r2=0.981, P<0.0001) and myocardial HSV1-sr39TK activity by tissue enzyme activity assay (r2=0.790, P<0.0001). Myocardial [18F]-FHBG accumulation was identified at viral titers down to 1x10(7) pfu. In 6 rats serially imaged up to day 17, myocardial [18F]-FHBG accumulation on microPET peaked on days 3 to 5 and was no longer identified on days 10 to 17. CONCLUSIONS: HSV1-sr39tk reporter gene expression can be monitored with [18F]-FHBG and microPET in rat myocardium quantitatively and serially with high detection sensitivity. Cardiac PET reporter gene imaging offers the potential of monitoring the expression of therapeutic genes in cardiac gene therapy.

Adenoviridae↗

124I-labeled engineered anti-CEA minibodies and diabodies allow high-contrast, antigen-specific small-animal PET imaging of xenografts in athymic mice.

UNLABELLED: Prolonged clearance kinetics have hampered the development of intact antibodies as imaging agents, despite their ability to effectively deliver radionuclides to tumor targets in vivo. Genetically engineered antibody fragments display rapid, high-level tumor uptake coupled with rapid clearance from the circulation in the athymic mouse/LS174T xenograft model. The anticarcinoembryonic antigen (CEA) T84.66 minibody (single-chain Fv fragment [scFv]-C(H)3 dimer, 80 kDa) and T84.66 diabody (noncovalent dimer of scFv, 55 kDa) exhibit pharmacokinetics favorable for radioimmunoimaging. The present work evaluated the minibody or diabody labeled with (124)I, for imaging tumor-bearing mice using a high-resolution small-animal PET system. METHODS: Labeling was conducted with 0.2-0.3 mg of protein and 65-98 MBq (1.7-2.6 mCi) of (124)I using an iodination reagent. Radiolabeling efficiencies ranged from 33% to 88%, and immunoreactivity was 42% (diabody) or >90% (minibody). In vivo distribution was evaluated in athymic mice bearing paired LS174T human colon carcinoma (CEA-positive) and C6 rat glioma (CEA-negative) xenografts. Mice were injected via the tail vein with 1.9-3.1 MBq (53-85 microCi) of (124)I-minibody or with 3.1 MBq (85 microCi) of (124)I-diabody and imaged at 4 and 18 h by PET. Some mice were also imaged using (18)F-FDG 2 d before imaging with (124)I-minibody. RESULTS: PET images using (124)I-labeled minibody or diabody showed specific localization to the CEA-positive xenografts and relatively low activity elsewhere in the mice, particularly by 18 h. Target-to-background ratios for the LS174T tumors versus soft tissues using (124)I-minibody were 3.05 at 4 h and 11.03 at 18 h. Similar values were obtained for the (124)I-diabody (3.95 at 4 h and 10.93 at 18 h). These results were confirmed by direct counting of tissues after the final imaging. Marked reduction of normal tissue activity, especially in the abdominal region, resulted in high-contrast images at 18 h for the (124)I-anti-CEA diabody. CEA-positive tumors as small as 11 mg (<3 mm in diameter) could be imaged, and (124)I-anti-CEA minibodies, compared with (18)F-FDG, demonstrated highly specific localization. CONCLUSION: (124)I labeling of engineered antibody fragments provides a promising new class of tumor-specific probes for PET imaging of tumors and metastases.

Animals↗

Noninvasive measurement of myocardial activity concentrations and perfusion defect sizes in rats with a new small-animal positron emission tomograph.

BACKGROUND: We explored the feasibility of measuring regional tracer activity concentrations and flow defects in myocardium of rats with a high spatial resolution small-animal PET system (microPET). METHODS AND RESULTS: Myocardial images were obtained after intravenous (18)F-fluorodeoxyglucose (18FDG) in 11 normal rats (group 1) and assembled into polar maps. Regional 18F activity concentrations were measured in 9 regions of interest and compared with tissue activity concentrations measured by well counting. In another 9 rats (group 2), myocardial perfusion images were acquired with 13N-ammonia at baseline and during coronary occlusion. On the polar maps recorded during coronary occlusion, the size of perfusion defects was measured as the myocardium with <50% of maximum activity and expressed as percent total myocardium and was correlated with the area at risk defined by postmortem staining. The diagnostic quality of 18FDG and 13N-ammonia microPET images was good to excellent; the images were easily assembled into polar maps. In group 1, regional (18)F concentrations by microPET and postmortem were correlated linearly (r=0.99; P<0.01 for average and r=0.97; P<0.01 for regional concentrations). In group 2, perfusion defect sizes by microPET and postmortem were correlated linearly (P<0.01; r=0.93). CONCLUSIONS: The findings indicate the feasibility of noninvasive studies of the myocardium in rats with a dedicated small-animal PET-imaging device.

Animals↗

PET scanners dedicated to molecular imaging of small animal models.

The dramatic advances of biological research in recent years that have focused on the molecular basis of how systems of the body (e.g. cells, organs and the whole organism) function, have increased the need for molecular imaging instrumentation. Of the several imaging modalities available today applied for in vivo studies of research animals, positron emission tomography (PET) is a technique that permits non-invasive use of positron labeled molecular imaging probes to image and assay biochemical processes of cellular function in the living subject. Imaging can be performed repeatedly before and after interventions and therefore allows the use of each animal as its own control. Many different positron labeled compounds have been and continue to be synthesized as probes that target a range of molecular targets within specific biochemical pathways. These molecular imaging probes are used in extremely low mass amounts, such that biological processes involving compounds in nanomolar concentration or lower can be imaged without disturbing the process. Biological processes from receptors and synthesis of transmitters in cell communication pathways, to metabolic processes and gene expression can be imaged. In the past, PET in animal research has been used extensively for studies of primates and larger animals. In recent years, the development of new detector technology has lowered the limits of spatial resolution. This has made it possible to use PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents some of the challenges facing small animal PET technology, provides an overview of the development of small animal PET systems, and discusses the current state of the art technology, some of its applications, as well as some future directions.

Journal Article↗

Molecular imaging of small animals with dedicated PET tomographs.

Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology.

Animals↗

An internet-based "kinetic imaging system" (KIS) for MicroPET.

Many considerations, involving understanding and selection of multiple experimental parameters, are required to perform MicroPET studies properly. The large number of these parameters/variables and their complicated interdependence make their optimal choice nontrivial. We have a developed kinetic imaging system (KIS), an integrated software system, to assist the planning, design, and data analysis of MicroPET studies. The system serves multiple functions-education, virtual experimentation, experimental design, and image analysis of simulated/experimental data-and consists of four main functional modules--"Dictionary," "Virtual Experimentation," "Image Analysis," and "Model Fitting." The "Dictionary" module provides didactic information on tracer kinetics, pharmacokinetic, MicroPET imaging, and relevant biological/pharmacological information. The "Virtual Experimentation" module allows users to examine via computer simulations the effect of biochemical/pharmacokinetic parameters on tissue tracer kinetics. It generates dynamic MicroPET images based on the user's assignment of kinetics or kinetic parameters to different tissue organs in a 3-D digital mouse phantom. Experimental parameters can be adjusted to investigate the design options of a MicroPET experiment. The "Image Analysis" module is a full-fledged image display/manipulation program. The "Model Fitting" module provides model-fitting capability for measured/simulated tissue kinetics. The system can be run either through the Web or as a stand-alone process. With KIS, radiotracer characteristics, administration method, dose level, imaging sequence, and image resolution-to-noise tradeoff can be evaluated using virtual experimentation. KIS is designed for biology/pharmaceutical scientists to make learning and applying tracer kinetics fun and easy.

Animals↗