Investigation of OPET Performance Using GATE, a Geant4-Based Simulation Software.

Abstract

A combined optical positron emission tomography (OPET) system is capable of both optical and PET imaging in the same setting, and it can provide information/interpretation not possible in single-mode imaging. The scintillator array here serves the dual function of coupling the optical signal from bioluminescence/fluorescence to the photodetector and also of channeling optical scintillations from the gamma rays. We report simulation results of the PET part of OPET using GATE, a Geant4 simulation package. The purpose of this investigation is the definition of the geometric parameters of the OPET tomograph. OPET is composed of six detector blocks arranged in a hexagonal ring-shaped pattern with an inner radius of 15.6 mm. Each detector consists of a two-dimensional array of 8 × 8 scintillator crystals each measuring 2 × 2 × 10 mm(3). Monte Carlo simulations were performed using the GATE software to measure absolute sensitivity, depth of interaction, and spatial resolution for two ring configurations, with and without gantry rotations, two crystal materials, and several crystal lengths. Images were reconstructed with filtered backprojection after angular interleaving and transverse one-dimensional interpolation of the sinogram. We report absolute sensitivities nearly seven times that of the prototype microPET at the center of field of view and 2.0 mm tangential and 2.3 mm radial resolutions with gantry rotations up to an 8.0 mm radial offset. These performance parameters indicate that the imaging spatial resolution and sensitivity of the OPET system will be suitable for high-resolution and high-sensitivity small-animal PET imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fernando R Rannou, Vandana Kohli, David L Prout, Arion F Chatziioannou. 2004. Investigation of OPET Performance Using GATE, a Geant4-Based Simulation Software.. https://doi.org/10.1109/tns.2004.835737

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effectiveness of high-dose versus standard-dose influenza vaccines against hospitalisation according to frailty risk: a prespecified analysis of the randomised trial DANFLU-2.

BACKGROUND: Frailty is a major risk factor for influenza-related complications and can influence vaccine effectiveness. We aimed to assess the relative vaccine effectiveness (rVE) of high-dose (HD-IIV) versus standard-dose inactivated influenza vaccine (SD-IIV) in older adults aged 65 years or older according to frailty risk. METHODS: This study was a prespecified analysis of DANFLU-2, an open-label, individually randomised trial, conducted in Denmark during three consecutive influenza seasons (2022-23, 2023-24, and 2024-25). Adults aged 65 years or older were randomised (1:1) to the HD-IIV or SD-IIV group. The primary endpoint was hospitalisation for influenza or pneumonia. Frailty was defined according to the validated Hospital Frailty Risk Score (HFRS) based on ICD-10 codes within 10 years before randomisation. Participants were stratified into three HFRS categories, namely low (<5 points), intermediate (5-15 points), and high (>15 points) frailty risk. The rVE of HD-IIV versus SD-IIV against the primary endpoint was assessed across prespecified HFRS categories and treating HFRS as a continuous variable. Pearson's chi-square test was used to compare safety events across frailty risk groups and randomisation groups. FINDINGS: Among 332&#x2009;438 randomised participants (mean age 73&#xb7;7 years [SD 5&#xb7;8]; 161&#x2009;538 [48&#xb7;6%] were female), 276&#x2009;173 (83&#xb7;1%) had low frailty risk, 52&#x2009;395 (15&#xb7;8%) had intermediate frailty risk, and 3861 (1&#xb7;2%) had high frailty risk. The primary endpoint of hospitalisation for influenza or pneumonia occurred in 1424 (0&#xb7;5%) of 276&#x2009;173 participants with low frailty risk, 761 (1&#xb7;5%) of 52&#x2009;395 with intermediate frailty risk, and 163 (4&#xb7;2%) of 3861 with high frailty risk (relative risk [RR] for intermediate vs low frailty risk 2&#xb7;8 [95% CI 2&#xb7;6-3&#xb7;1]; RR for high vs low frailty risk 8&#xb7;2 [7&#xb7;0-9&#xb7;6]). HFRS as a continuous variable significantly modified the effect of HD-IIV versus SD-IIV against the primary endpoint with higher rVE estimates with increasing HFRS (pinteraction=0&#xb7;020). The rVE was 0&#xb7;2% (95% CI -10&#xb7;8 to 10&#xb7;2) among those with low frailty risk, 13&#xb7;1% (-0&#xb7;4 to 24&#xb7;8) among those with intermediate frailty risk, and 19&#xb7;9% (-10&#xb7;3 to 42&#xb7;1) among those with high frailty risk. No significant interaction was observed when HFRS was assessed according to the prespecified categorical frailty groups (pinteraction=0&#xb7;17). The proportion of participants with at least one serious adverse event increased across frailty risk groups (13&#x2009;366 [4&#xb7;8%] of 275&#x2009;795 for low frailty risk, 5475 [10&#xb7;5%] of 52&#x2009;315 for intermediate frailty risk, and 777 [20&#xb7;2%] of 3850 for high frailty risk; p<0&#xb7;0001), with similar proportions of serious adverse events in the HD-IIV and SD-IIV groups for each frailty risk group. INTERPRETATION: Among adults aged 65 years or older in Denmark, frailty risk might modify the effects of HD-IIV versus SD-IIV against hospitalisation for influenza or pneumonia, with higher rVE estimates with increasing frailty risk. These findings might support considering high-dose influenza vaccines for frail older adults. However, effect modification was not evident when frailty was assessed using prespecified categorical subgroups, and subgroup-specific estimates were imprecise, with 95% CIs crossing the null. These results should be considered exploratory, warranting further investigation. FUNDING: The DANFLU-2 trial was funded by Sanofi.

Journal Article↗