PubMed Health⌕ Search

Biomedical subjects

Arndt-Holger Kiessling

Publications and source records attributed to Arndt-Holger Kiessling.

2 recordsLinked to original sources

Diltiazem may preserve renal tubular integrity after cardiac surgery.

PURPOSE: To evaluate the influence of dopamine and diltiazem on renal function and markers for acute renal failure, including urinary alpha-glutathion s-transferase (alpha-GST), alpha-1-microglobulin (alpha(1)-MG) and N-acetyl-ss-glucosaminidase (ss-NAG) after extracorporeal circulation. METHODS: In a randomized, placebo-controlled, double-blind trial we evaluated the efficacy of dopamine (2.5 micro g x kg(-1) x min(-1)), diltiazem (2 micro g x kg(-1) x min(-1)) or placebo administered over 48 hr postoperatively to maintain renal tubular integrity in 60 elective cardiac surgery patients. alpha-GST, alpha(1)-MG, ss-NAG, and creatinine clearance were measured from urine collected during surgery (T0), the first four hours (T1), 24 hr (T2) and 48 hr (T3) postoperatively. RESULTS: Cumulative urine output in the diltiazem group (9.0 +/- 2.8 L) increased significantly compared with placebo (7.0 +/- 1.6 L), but not compared with dopamine (7.8 +/- 1.8 L). Creatinine clearance showed no significant intergroup differences. In all groups alpha(1)-MG increased from T0 to T3, but we found no significant intergroup differences. alpha-GST increased significantly from T0 to T3 in the placebo (2.1 +/- 1.8 to 11.4 +/- 8.6 micro g x L(-1)) and in the dopamine groups (2.7 +/- 1.8 to 13.6 +/- 14.9 micro g x L(-1)), but not in the diltiazem group (1.8 +/- 1.4 to 3.2 +/- 3.2 micro g x L(-1)). Forty-eight hours postoperatively alpha-GST was significantly lower in the diltiazem group than in both other groups. CONCLUSIONS: Diltiazem stimulates urine output, reduces excretion of alpha-GST and ss-NAG and may be useful to maintain tubular integrity after cardiac surgery.

Acetylglucosaminidase↗

Robotic surgery using Zeus MicroWrist technology: the next generation.

BACKGROUND: The use of computer-animated surgical instruments for various cardiac operations has been shown to be feasible, but to date, the available information regarding the operative and technical details of these procedures is still inadequate. METHODS: We used the Zeus (Computer Motion Inc., Goleta, Calif, USA) telemanipulation system to perform the internal mammary artery (IMA) takedown in 56 patients, in 12 of whom we used the newest model with MicroWristTM (Computer Motion Inc., Goleta, Calif, USA) technology. Port orientation was based on thoracic anatomy, the decisive landmarks being the mammillary line and the axillary line. The distance between ports was at least 9 cm, and the patient's arm was positioned with the left shoulder raised and angulated by not more than 90 degrees. RESULTS: Mean setup time was 44 +/- 18 minutes for the first five patients and 16 +/- 7 minutes for the last five patients, with an overall average of 24 +/- 12 minutes. IMA harvest time at the beginning reached a mean of 95 +/- 23 minutes and decreased to 44 +/- 18 minutes in the last five cases. Average IMA takedown time was 58 +/- 17 minutes. The IMA was patent with a good flow in all 56 patients. CONCLUSIONS: The introduction of robotic technology into clinical routine has resulted in safe procedures with a short learning curve. However, basic training in the modality is a must in order to achieve technical excellence.

Cardiac Surgical Procedures↗