Robotic surgery using Zeus MicroWrist technology: the next generation.

Abstract

BACKGROUND: The use of computer-animated surgical instruments for various cardiac operations has been shown to be feasible, but to date, the available information regarding the operative and technical details of these procedures is still inadequate. METHODS: We used the Zeus (Computer Motion Inc., Goleta, Calif, USA) telemanipulation system to perform the internal mammary artery (IMA) takedown in 56 patients, in 12 of whom we used the newest model with MicroWristTM (Computer Motion Inc., Goleta, Calif, USA) technology. Port orientation was based on thoracic anatomy, the decisive landmarks being the mammillary line and the axillary line. The distance between ports was at least 9 cm, and the patient's arm was positioned with the left shoulder raised and angulated by not more than 90 degrees. RESULTS: Mean setup time was 44 +/- 18 minutes for the first five patients and 16 +/- 7 minutes for the last five patients, with an overall average of 24 +/- 12 minutes. IMA harvest time at the beginning reached a mean of 95 +/- 23 minutes and decreased to 44 +/- 18 minutes in the last five cases. Average IMA takedown time was 58 +/- 17 minutes. The IMA was patent with a good flow in all 56 patients. CONCLUSIONS: The introduction of robotic technology into clinical routine has resulted in safe procedures with a short learning curve. However, basic training in the modality is a must in order to achieve technical excellence.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Frank Isgro, Arndt-Holger Kiessling, Markus Blome, Andreas Lehmann, Bernhard Kumle, Werner Saggau. Robotic surgery using Zeus MicroWrist technology: the next generation.. https://doi.org/10.1046/j.1540-8191.2003.01901.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

3D heart model for computer simulations in cardiac surgery.

For a satisfactory computer simulation, a model, which imitates a natural situation, is needed. The Human heart is an irregular 3D object and thus difficult to reproduce. Basic data was taken from Visible Human Dataset (VHD), National Library of Medicine. The heart area was cut out of the original cross-sections and different tissues segmented. All the slices also had to be aligned to assure precise overlapping of the structures. A 3D computer heart model with the resolution of 1mm was designed. The heart model was dedicated to simulations of heat transfer during heart surgery however, it is applicable also to other medical simulations.

Cardiac Surgical Procedures↗