Performance evaluation of a multi-slice CT system with 16-slice detector and increased gantry rotation speed for isotropic submillimeter imaging of the heart.

BACKGROUND: 4-slice CT scanners have shown limitations in clinical application for noninvasive coronary CT angiography (CTA). We evaluate advances in ECG-gated scanning of the heart and the coronary arteries with recently introduced 16-slice CT equipment (SOMATOM Sensation 16, Siemens, Forchheim, Germany). MATERIALS AND METHODS: The technical principles of ECG-gated cardiac scanning, scan parameters, and detector design of the new scanner are presented. ECG-gated scan and image reconstruction techniques and ECG-controlled dose modulation ("ECG pulsing") for a reduction of the patient dose are described, key parameters for image quality and simulation results presented, and phantom studies and initial patient experience discussed. The impact of reduced gantry rotation time (0.42 s) on temporal resolution and initial estimations of the patient dose are presented. RESULTS: Extensions of ECG-gated reconstruction algorithms used for 4-slice CT provide adequate image quality for up to 16 slices. For each detector collimation different slice widths are available for retrospective reconstruction with well-defined slice sensitivity profiles (SSPs). For coronary CTA the heart can be covered with 0.75 mm collimation within a 20-s breathhold. The best possible spatial resolution is 0.5 x 0.5 x 0.6 mm. For 0.42 s gantry rotation time, temporal resolution reaches its optimum (105 ms) at a heart rate of 81 bpm. Effective patient dose for coronary CTA is 4-5 mSv using ECG-pulsed acquisition. CONCLUSION: The clinical performance of coronary CTA by means of spatial resolution, temporal resolution and scan time is substantially improved with the evaluated 16-slice CT scanner. Also, display of smaller coronary segments and instent visualization are substantially improved.

Algorithms↗

MDCT: cardiology indications.

In the past 2 years mechanical multidetector-row CT (MDCT) systems with simultaneous acquisition of four slices and half-second scanner rotation have become widely available. Data acquisition with these scanners allows for considerably faster coverage of the heart volume compared with single-slice scanning. This increased scan speed can be used for retrospective gating together with 1-mm collimated slice widths and allows coverage of the entire cardiac volume in one breath hold. Initial results from studies in correlation with intracoronary ultrasound suggest that MDTC technology not only offers the possibility to visualize intracoronary stenoses non-invasively but also to differentiate plaque morphology. This is especially the case with the next generation of 16-row multidetector CT. An increased number of simultaneously acquired slices and sub-millimeter collimation for cardiac applications allows true isotropic scanning with high temporal resolution. Contrast-enhanced MDTC is a promising non-invasive technique for the detection, visualization, and characterization of stenotic artery disease. It could act as a gate keeper prior to cardiac catherization and finally replace conventional diagnostic modalities.

Calcinosis↗

Virtual bronchoscopy: comparison of different surface rendering models.

The aim of this study was to compare different representation models of surface-rendered virtual bronchoscopy. 10 consecutive patients with inoperable primary lung tumors underwent thin-section spiral computed tomography. The structures of interest, the tracheobronchial system and anatomical and pathological thoracic structures were segmented using an interactive threshold interval volume-growing segmentation algorithm and visualized with the aid of a color-coded surface rendering method. For virtual bronchoscopy, the tracheobronchial system was visualized using a triangle-surface rendering model, a shaded-surface rendering model and a transparent shaded-surface rendering model. The triangle-surface rendering model allowed optimum detailed spatial representation of the dimensions of extraluminal anatomical and pathological mediastinal structures. As the lumen of the tracheobronchial system was less well defined, the rendering model was of limited use for depiction of the airway surface. The shaded-surface rendering model facilitated an optimum assessment of the airway surface, but the mediastinal structures could not be depicted. The transparent shaded-surface rendering model provides simultaneous adequate to optimum visualization and assessment of the intraluminal airway surface and the extraluminal mediastinal structures as well as a quantitative assessment of the spatial relationship between these structures. Fast data acquisition with a multi-slice detector spiral computed tomography scanner and the use of virtual bronchoscopy with the transparent shaded-surface rendering model obviate the need for time consuming detailed analysis and presentation of axial source images by providing improved the diagnostic imaging of endotracheal and endobronchial diseases and offering a useful alternative to fiberoptic bronchoscopy.

Bronchoscopy↗

Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT.

PURPOSE: To methodically evaluate the reproducibility and accuracy of coronary arterial calcification measurements by using spiral multi-detector row and electron-beam computed tomography (CT) with a beating heart phantom. MATERIALS AND METHODS: A phantom was built to mimic a beating heart with coronary arteries and calcified plaques. The simulated vessels moved in a pattern similar to that of a beating heart. The phantom operated at a variety of pulse rates (0-140 beats per minute). The phantom was repeatedly scanned in various positions by using various protocols with electron-beam and multi-detector row CT scanners to assess interexamination variability. Statistical analysis was performed to determine significant differences in interexamination variability for various acquisition protocols. RESULTS: Electrocardiographically (EKG) gated volume coverage with spiral multi-detector row CT (2.5-mm collimation) and overlapping image reconstruction (1-mm increment) was found to significantly improve the reliability of coronary arterial calcium quantification, especially for small plaques (P <.05). Mean interexamination variability was reduced from 35% +/- 6 (SD) (Agatston score, standard electron-beam CT) to 4% +/- 2 (P <.05) (volumetric score, spiral EKG-gated multi-detector row CT). CONCLUSION: By coupling retrospective gating with nearly isotropic volumetric imaging data, spiral multi-detector row CT provides better input data for quantification of coronary arterial calcium volume. Multi-detector row CT allows precise and repeated measurement of coronary arterial calcification, with low interexamination variability.

Calcinosis↗