PubMed Health⌕ Search

PubMed · 16341833

First performance evaluation of a dual-source CT (DSCT) system.

Abstract

We present a performance evaluation of a recently introduced dual-source computed tomography (DSCT) system equipped with two X-ray tubes and two corresponding detectors, mounted onto the rotating gantry with an angular offset of 90 degrees . We introduce the system concept and derive its consequences and potential benefits for electrocardiograph [corrected] (ECG)-controlled cardiac CT and for general radiology applications. We evaluate both temporal and spatial resolution by means of phantom scans. We present first patient scans to illustrate the performance of DSCT for ECG-gated cardiac imaging, and we demonstrate first results using a dual-energy acquisition mode. Using ECG-gated single-segment reconstruction, the DSCT system provides 83 ms temporal resolution independent of the patient's heart rate for coronary CT angiography (CTA) and evaluation of basic functional parameters. With dual-segment reconstruction, the mean temporal resolution is 60 ms (minimum temporal resolution 42 ms) for advanced functional evaluation. The z-flying focal spot technique implemented in the evaluated DSCT system allows 0.4 mm cylinders to be resolved at all heart rates. First clinical experience shows a considerably increased robustness for the imaging of patients with high heart rates. As a potential application of the dual-energy acquisition mode, the automatic separation of bones and iodine-filled vessels is demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thomas G Flohr, Cynthia H McCollough, Herbert Bruder, Martin Petersilka, Klaus Gruber, Christoph Süss, Michael Grasruck, Karl Stierstorfer, Bernhard Krauss, Rainer Raupach, Andrew N Primak, Axel Küttner, Stefan Achenbach, Christoph Becker, Andreas Kopp, Bernd M Ohnesorge. 2005-12-10. First performance evaluation of a dual-source CT (DSCT) system.. https://doi.org/10.1007/s00330-005-2919-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Repeat right transradial percutaneous coronary intervention in a patient with dextrocardia: the right approach to the right-sided heart.

Dextrocardia (DC) is a rare cardiac condition in which the cardiac location, as well as apex, is rightwardly displaced. As the incidence of atherosclerotic disease is similar to that of the general population, there have been few reports of percutaneous coronary interventions (PCIs) in these patients. Proposed technical strategies for successful angiography and PCI in DC include counter-directional torquing of the catheter, as well as right-left mirror-image inversion angiographic views. All previous reports of DC PCIs have been via transfemoral access.We present a case of successful repeat transradial PCI in a patient with DC. This is first report of transradial coronary angiography, PCI, or repeat PCI in a DC patient. A literature review of technical considerations, including our own recommendations for guide catheter selection, are discussed. We also review the anatomic variations and epidemiology of DC. Although access complications for transradial PCI is known to be lower than that of the transfemoral approach, challenges in technique and concern of repeat access have limited the popularity of the former. Our report demonstrates the safety and feasibility of transradial angiography, PCI, and even repeat PCI, in the rare patient with DC.

Coronary Angiography↗