PubMed Health⌕ Search

Biomedical subjects

B A Tichenor

Publications and source records attributed to B A Tichenor.

5 recordsLinked to original sources

Volatile organic compound emissions from latex paint--Part 1. Chamber experiments and source model development.

Latex paints are widely used in residential and commercial indoor environments. The surface areas covered by the paints in these environments are relatively large. Thus, latex paints have the potential for having a major impact on indoor air quality (IAQ). A study was undertaken to develop methods for evaluating the impact of latex paint emission on IAQ. Small chamber experiments using stainless steel and painted and unpainted gypsum board substrates were conducted to determine the emission characteristics of latex paint. The emissions from the stainless steel were relatively short lived (3 to 4 days), whereas the emissions from gypsum board lasted for over 200 days. Because gypsum board is a common substrate for latex paint, all emission models were developed for the gypsum board substrates. The data from the small chamber tests led to the development of two empirical and two mass-transfer-based source emission models. Approximately 100 to 200 days of data were required to estimate the parameters required for the empirical models. Only 8 days of data were required to estimate the parameters for the mass-transfer-based models. The final models use paint formulation and mass transfer correlations to predict the emissions of the major individual volatile organic compounds emitted by latex paint.

Air Pollution, Indoor↗

Volatile organic compound emissions from latex paint--Part 2. Test house studies and indoor air quality (IAQ) modeling.

Emission models developed using small chamber data were combined with an Indoor Air Quality (IAQ) model to analyze the impact of volatile organic compound (VOC) emissions from latex paint on indoor environments. Test house experiments were conducted to verify the IAQ model's predictions. The agreement between model predictions and experimental measurements met the American Society for Testing and Materials criteria for model verification in the room with the source and met most of the requirements in other rooms. The major cause of disagreement between the model predictions and the experimental data in the test house appears to be an inadequate sink model.

Air Pollution, Indoor↗

The temperature dependence of the emission of perchloroethylene from dry cleaned fabrics.

A study was conducted to evaluate the emission of perchloroethylene (tetrachloroethylene) from freshly dry cleaned fabrics using small environmental test chambers. The temperature dependence of the release of perchloroethylene was evaluated over a temperature range of 20 to 45 degrees C. A linear relation exists between the logarithm of perchloroethylene retention time (tau) and the reciprocal of the absolute temperature (1/T). The temperature dependence of the retention time can be expressed as tau = 2.36 x 10(-16)e13,892/T and 8.38 x 10(-9)e8766/T sec for 100% wool and 55% polyester/45% wool fabrics, respectively. These results indicate that "airing out" freshly dry cleaned fabrics at temperatures near 20 degrees C for short time periods (e.g., 5 hr) will not appreciably reduce the total emissions of perchloroethylene.

Adsorption↗

Evaluating sources of indoor air pollution.

Evaluation of indoor air pollution problems requires an understanding of the relationship between sources, air movement, and outdoor air exchange. Research is underway to investigate these relationships. A three-phase program is being implemented: 1) Environmental chambers are used to provide source emission factors for specific indoor pollutants; 2) An IAQ (Indoor Air Quality) model has been developed to calculate indoor pollutant concentrations based on chamber emissions data and the air exchange and air movement within the indoor environment; and 3) An IAQ test house is used to conduct experiments to evaluate the model results. Examples are provided to show how this coordinated approach can be used to evaluate specific sources of indoor air pollution. Two sources are examined: 1) para-dichlorobenzene emissions from solid moth repellant; and 2) particle emissions from unvented kerosene heaters. The evaluation process for both sources followed the three-phase approach discussed above. Para-dichlorobenzene emission factors were determined by small chamber testing at EPA's Air and Energy Engineering Research Laboratory. Particle emission factors for the kerosene heaters were developed in large chambers at the J. B. Pierce Foundation Laboratory. Both sources were subsequently evaluated in EPA's IAQ test house. The IAQ model predictions showed good agreement with the test house measurements when appropriate values were provided for source emissions, outside air exchange, in-house air movement, and deposition on "sink" surfaces.

Air Pollution↗