Volatile organic compound emissions from latex paint--Part 1. Chamber experiments and source model development.

Abstract

Latex paints are widely used in residential and commercial indoor environments. The surface areas covered by the paints in these environments are relatively large. Thus, latex paints have the potential for having a major impact on indoor air quality (IAQ). A study was undertaken to develop methods for evaluating the impact of latex paint emission on IAQ. Small chamber experiments using stainless steel and painted and unpainted gypsum board substrates were conducted to determine the emission characteristics of latex paint. The emissions from the stainless steel were relatively short lived (3 to 4 days), whereas the emissions from gypsum board lasted for over 200 days. Because gypsum board is a common substrate for latex paint, all emission models were developed for the gypsum board substrates. The data from the small chamber tests led to the development of two empirical and two mass-transfer-based source emission models. Approximately 100 to 200 days of data were required to estimate the parameters required for the empirical models. Only 8 days of data were required to estimate the parameters for the mass-transfer-based models. The final models use paint formulation and mass transfer correlations to predict the emissions of the major individual volatile organic compounds emitted by latex paint.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L E Sparks, Z Guo, J C Chang, B A Tichenor. 1999. Volatile organic compound emissions from latex paint--Part 1. Chamber experiments and source model development.. https://doi.org/10.1111/j.1600-0668.1999.t01-3-00003.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pilot study of indoor radon in Greek workplaces.

Radon and gamma dose rate measurements have been performed in 561 workplaces in 19 prefectures of Greece. The distribution of radon concentration can be well described by a log-normal distribution. Most of the radon concentrations are between 50 and 200 Bq m(-3) with an arithmetic mean of 123 Bq m(-3). The maximum measured value of radon gas concentration is 695 Bq m(-3). About 10% of the workplaces exceed 200 Bq m(-3). Only a small fraction ( approximately 1%) of workplaces exceed the European Commission action level (400 Bq m(-3)). Despite the relative small fraction of workplaces which exceed the value of 400 Bq m(-3), it is clear from the results of the present work that for certain prefectures, further and more extensive research is needed.

Air Pollution, Indoor↗

Health effects of arsenic, fluorine, and selenium from indoor burning of Chinese coal.

China's economy has developed rapidly in the last two decades, leading to an increase in energy consumption and consequently emissions from energy generation. Coal is a primary energy source in China because of its abundance and will continue to be used in the future. The dominance of coal in energy production is expected to result in increasing levels of exposure to environmental pollution in China. Toxic trace elements emitted during coal combustion are the main sources of indoor air pollution. They are released into the atmosphere mainly in the forms of fine ash and vapors and have the potential to adversely affect human health. Those trace elements, which volatilize during combustion, are hazardous air pollutants (HAPs) and are particularly rich in Chinese coals. Among the HAPs, arsenic (As), fluorine (F), and selenium (Se) have already been identified as pollutants that can induce severe health problems. In this review, the geochemical characteristics of As, F, and Se, including their concentration, distribution, and mode of occurrences in Chinese coal, are documented and discussed. Our investigations have confirmed the current As- and F-induced epidemics in Guizhou (Southwest China) and Se epidemic in Hubei (Northeast China). In this study, diagnostic symptoms of arseniasis, fluorosis, and selenosis are also illustrated.

Air Pollution, Indoor↗