PubMed Health⌕ Search

Biomedical subjects

B B Bart

Publications and source records attributed to B B Bart.

2 recordsLinked to original sources

The prone position is associated with a decrease in respiratory system compliance in healthy anaesthetized infants.

Ten healthy (ASA I or II) anaesthetized infants undergoing clubfoot surgery were studied. General anaesthesia included rocuronium, nitrous oxide and isoflurane. Volume controlled ventilation (12 ml.kg-1) was delivered via a coaxial Mapleson-D (Bain) system and a Datex AS/3 ventilator. Pulmonary mechanics were measured sequentially in the supine and prone positions using a Bicore CP-100 pulmonary function monitor. Subjects had a mean age of 6 (+/- 2) months and a mean weight of 8.3 (+/- 1.4) kg. Dynamic compliance (CDYN) and static compliance (CSTAT) were both significantly lower in the prone position than in the supine position (P < 0.0005). Mean CDYN decreased from 14.9 +/- 4.9 ml.cmH2O-1 (supine) to 11.6 +/- 3.5 ml.cmH2O-1 (prone). Mean CSTAT decreased from 10.2 +/- 2.8 ml.cmH2O-1 (supine) to 8.9 +/- 2.3 ml.cmH2O-1 (prone). No clinically significant differences in gas exchange were noted, however, on repositioning.

Anesthesia, General↗