The prone position is associated with a decrease in respiratory system compliance in healthy anaesthetized infants.

Abstract

Ten healthy (ASA I or II) anaesthetized infants undergoing clubfoot surgery were studied. General anaesthesia included rocuronium, nitrous oxide and isoflurane. Volume controlled ventilation (12 ml.kg-1) was delivered via a coaxial Mapleson-D (Bain) system and a Datex AS/3 ventilator. Pulmonary mechanics were measured sequentially in the supine and prone positions using a Bicore CP-100 pulmonary function monitor. Subjects had a mean age of 6 (+/- 2) months and a mean weight of 8.3 (+/- 1.4) kg. Dynamic compliance (CDYN) and static compliance (CSTAT) were both significantly lower in the prone position than in the supine position (P < 0.0005). Mean CDYN decreased from 14.9 +/- 4.9 ml.cmH2O-1 (supine) to 11.6 +/- 3.5 ml.cmH2O-1 (prone). Mean CSTAT decreased from 10.2 +/- 2.8 ml.cmH2O-1 (supine) to 8.9 +/- 2.3 ml.cmH2O-1 (prone). No clinically significant differences in gas exchange were noted, however, on repositioning.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R G Cox, A Ewen, B B Bart. 2001. The prone position is associated with a decrease in respiratory system compliance in healthy anaesthetized infants.. https://doi.org/10.1046/j.1460-9592.2001.00646.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The employment of an iterative design process to develop a pulmonary graphical display.

OBJECTIVE: Data representations on today's medical monitors need to be improved to advance clinical awareness and prevent data vigilance errors. Simply building graphical displays does not ensure an improvement in clinical performance because displays have to be consistent with the user's clinical processes and mental models. In this report, the development of an original pulmonary graphical display for anesthesia is used as an example to show an iterative design process with built-in usability testing. DESIGN: The process reported here is rapid, inexpensive, and requires a minimal number of subjects per development cycle. Three paper-based tests evaluated the anatomic, variable mapping, and graphical diagnostic meaning of the pulmonary display. MEASUREMENTS: A confusion matrix compared the designer's intended answer with the subject's chosen answer. Considering deviations off the diagonal of the confusion matrix as design weaknesses, the pulmonary display was modified and retested. The iterative cycle continued until the anatomic and variable mapping cumulative test scores for a chosen design scored above 90% and the graphical diagnostic meaning test scored above 75%. RESULTS: The iterative development test resulted in five design iterations. The final graphical pulmonary display improved the overall intuitiveness by 18%. The display was tested in three categories: anatomic features, variable mapping, and diagnostic accuracy. The anatomic intuitiveness increased by 25%, variable mapping intuitiveness increased by 34%, and diagnostic accuracy decreased slightly by 4%. CONCLUSION: With this rapid iterative development process, an intuitive graphical display can be developed inexpensively prior to formal testing in an experimental setting.

Anesthesia, General↗