STR data for the PowerPlex 16 loci in Buenos Aires population (Argentina).
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to B Budowle.
Explore the source record for details and available documents.
During the past few years, the DNA Commission of the International Society of Forensic Genetics has published a series of documents providing guidelines and recommendations concerning the application of DNA polymorphisms to the problems of human identification. This latest report addresses a relatively new area - namely, Y-chromosome polymorphisms, with particular emphasis on short tandem repeats (STRs). This report addresses nomenclature, use of allelic ladders, population genetics and reporting methods.
Over 1500 population database samples comprising African Americans, Caucasians, Hispanics, Native Americans, Chamorros and Filipinos were typed using the PowerPlex 16 and the Profiler Plus/COfiler kits. Except for the D8S1179 locus in Chamorros and Filipinos from Guam, there were eight examples in which a typing difference due to allele dropout was observed. At the D8S1179 locus in the population samples from Guam, there were 13 examples of allele dropout observed when using the Profiler Plus kit. The data support that the primers used in the PowerPlex 16, Profiler Plus, and COfiler kits are reliable for typing reference samples that are for use in CODIS. In addition, allele frequency databases have been established for the STR loci Penta D and Penta E. Both loci are highly polymorphic.
Allele frequencies for 13 tetrameric short tandem repeat (STR) loci, CSF1PO, D18S51, D3S1358, D21S11, D5S818, FGA, D7S820, HUMTH01, D8S1179, TPOX, D13S317, VWA, and D16S539 were determined on 198 Turkish blood samples.
Allele frequencies for the nine STRs included in the AMPFlSTR kit were obtained from a sample of 152 unrelated Greek Cypriot from the Mediterranean island of Cyprus
A population study on 10 short tandem repeat (STR) loci was performed on 202 unrelated Czech Caucasians. DNA, initially frozen, was thawed and placed FTA paper. The DNA was purified in situ. DNA was amplified by PCR using the AmpFlSTR SGM Plus amplification kit.
Allele frequencies for the 10 STRs loci included in the AmpFISTR SGM Plus kit (PE Applied Biosystem) were obtained from a sample of 321 unrelated individuals born in Slovenia.
An Italian population study was performed on the loci D3S1358, vWA, FGA, TH01, TPOX, CSF1PO, D5S818, D13S317, D7S820 and a portion of the X-Y homologous gene Amelogenin for gender determination using the AmpFlSTR Profiler kit (PE Biosystems, Foster city, CA). This study was done on a population of 618 unrelated Italian individuals from 18 regions in Italy (except for Valle d'Aosta and Sardinia) to determine allele frequencies for each STR locus, and to evaluate STR technology for developing an Italian Offender DNA database.
During the past few years the DNA commission of the International Society of Forensic Genetics has published a series of documents providing guidelines and recommendations concerning the application of DNA polymorphisms to the problems of human identification. This latest report addresses a relatively new area, namely Y-chromosome polymorphisms, with particular emphasis on short tandem repeats (STRs). This report addresses nomenclature, use of allelic ladders, population genetics and reporting methods.
Slot blot hybridization of membrane-immobilized, single-stranded human DNA with the higher primate-specific alphoid probe D17Z1 is routinely used in forensic science to estimate the amount of DNA in biological samples. Typically, a chemiluminescent signal captured on film records the hybridization, and the quantity of the signal is related to the amount of immobilized DNA. Digital imaging using a cooled CCD camera offers an alternate non-film-based method for image acquisition with comparable sensitivity of detection, a greater dynamic range, enhanced capability of data interpretation, and often faster results than film. In addition, the data support the premise that more accurate and precise human DNA quantification should be obtained by not assuming a linear response of signal to known standards. Instead, quantity should be estimated using a second-order standard curve (R2 = 0.999). Finally, a CCD camera imaging system offers versatility for image capture of different signal sources and analysis of samples on a variety of support media.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Allele distributions for 12 or 13 CODIS core tetrameric short tandem repeat (STR) loci CSFIPO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, and vWA were determined in 41 population data sets. The major population groups comprise African Americans, U.S. Caucasians, Hispanics, Far East Asians, and Native Americans. There was little evidence for departures from Hardy-Weinberg expectations (HWE) in any of the populations. The FST estimates over all thirteen STR loci are 0.0006 for African Americans, -0.0005 for Caucasians, 0.0021 for Hispanics, 0.0039 for Asians, and 0.0282 for Native Americans.
Over 500 population database samples comprising African Americans, Bahamians, and Southwestern Hispanics were typed using the PowerPlex 16 and the Profiler Plus COfiler kits. There was only one sample in which a typing difference was observed. An FGA heterozygote profile was observed using the PowerPlex 16 primers, and a single allele FGA profile was observed using Profiler Plus primers. Thus, the extant data suggest that the primers used in the PowerPlex 16, Profiler Plus, and COfiler kits are reliable for typing reference samples destined for use in CODIS. In addition, African American, Bahamian, and Southwestern Hispanic databases have been established for the STR loci Penta D and Penta E. Both loci are highly polymorphic. The application of the product rule is valid for estimating the rarity of a multiple loci profile consisting of these two and the 13 core STR loci.
The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.
With the use of capillary electrophoresis (CE), high-resolution electrophoretic separation of short tandem repeat (STR) loci can be achieved in a semiautomated fashion. Laser-induced detection of fluorescently labeled PCR products and multicolor analysis enable the rapid generation of multilocus DNA profiles. In this study, conditions for typing PCR-amplified STR loci by capillary electrophoresis were investigated using the ABI Prism 310 Genetic Analyzer (Applied Biosystems). An internal size standard was used with each run to effectively normalize mobility differences among injections. Alleles were designated by comparison to allelic ladders that were run with each sample set. Multiple runs of allelic ladders and of amplified samples demonstrate that allele sizes were reproducible, with standard deviations typically less than 0.12 bases for fragments up to 317 bases in length (largest allele analyzed) separated in a 47 cm capillary. Therefore, 99.7% of all alleles that are the same length should fall within the measurement error window of +/- 0.36 bases. Microvariants of the tetranucleotide repeats were also accurately typed by the analytical software. Alleles differing in size by one base could be resolved in two-donor DNA mixtures in which the minor component comprised > or = 5% of the total DNA. Furthermore, the quantitative data format (i.e., peak amplitude) can in some instances assist in determining individual STR profiles in mixed samples. DNA samples from previously typed cases (typed for RFLP, AmpliType PM+DQA1, and/or D1S80) were amplified using AmpFlSTR Profiler Plus and COfiler and were evaluated using the ABI Prism 310. Most samples yielded typable results. Compared with previously determined results for other loci, there were no discrepancies as to the inclusion or exclusion of suspects or victims. CE thus provides efficient separation, resolution, sensitivity and precision, and the analytical software provides reliable genotyping of STR loci. The analytical conditions described are suitable for typing samples such as reference and evidentiary samples from forensic casework.