PubMed Health⌕ Search

PubMed · 11373002

Concordance study on population database samples using the PowerPlex 16 kit and AmpFlSTR Profiler Plus kit and AmpFlSTR COfiler kit.

Abstract

Over 500 population database samples comprising African Americans, Bahamians, and Southwestern Hispanics were typed using the PowerPlex 16 and the Profiler Plus COfiler kits. There was only one sample in which a typing difference was observed. An FGA heterozygote profile was observed using the PowerPlex 16 primers, and a single allele FGA profile was observed using Profiler Plus primers. Thus, the extant data suggest that the primers used in the PowerPlex 16, Profiler Plus, and COfiler kits are reliable for typing reference samples destined for use in CODIS. In addition, African American, Bahamian, and Southwestern Hispanic databases have been established for the STR loci Penta D and Penta E. Both loci are highly polymorphic. The application of the product rule is valid for estimating the rarity of a multiple loci profile consisting of these two and the 13 core STR loci.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Budowle, C J Sprecher. 2001. Concordance study on population database samples using the PowerPlex 16 kit and AmpFlSTR Profiler Plus kit and AmpFlSTR COfiler kit.. https://pubmed.ncbi.nlm.nih.gov/11373002/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Run-specific limits of detection and quantitation for STR-based DNA testing.

STR-based DNA profiling is an exceptionally sensitive analytical technique that is often used to obtain results at the very limits of its sensitivity. The challenge of reliably distinguishing between signal and noise in such situations is one that has been rigorously addressed in numerous other analytical disciplines. However, an inability to determine accurately the height of electropherogram baselines has caused forensic DNA profiling laboratories to utilize alternative approaches. Minimum thresholds established during laboratory validation studies have become the de facto standard for distinguishing between reliable signal and noise/technical artifacts. These minimum peak height thresholds generally fail to consider variability in the sensitivity of instruments, reagents, and the skill of human analysts involved in the DNA profiling process over the course of time. Software (BatchExtract) made publicly available by the National Center for Biotechnology Information now provides an alternative means of establishing limits of detection and quantitation that is more consistent with those used in other analytical disciplines. We have used that software to determine the height of each data collection point for each dye along a control sample's electropherogram trace. These values were then used to determine a limit of detection (the average amount of background noise plus three standard deviations) and a limit of quantitation (the average amount of background noise plus 10 standard deviations) for each control sample. Analyses of the electropherogram data associated with the positive, negative, and reagent blank controls included in 50 different capillary electrophoresis runs validate that this approach could be used to determine run-specific thresholds objectively for use in forensic DNA casework.

DNA Fingerprinting↗