PubMed Health⌕ Search

Biomedical subjects

B D Fornage

Publications and source records attributed to B D Fornage.

At least 37 records · Page 2Linked to original sources

Role of color Doppler imaging in differentiating between pseudocystic malignant tumors and fluid collections.

The differentiation between a pseudocystic solid tumor and a fluid collection containing echoes is sometimes difficult. The purpose of this study was to evaluate the contribution of color Doppler sonography in confirming the solid nature of pseudocystic malignant tumors by demonstrating internal vascularity. Fourteen consecutive masses with an indeterminate solid or cystic appearance on conventional sonograms were evaluated with color Doppler sonography for the presence of blood flow within the boundaries of the mass. Color Doppler sonography demonstrated the presence of some blood flow in all 12 solid malignant tumors, whereas no flow was visualized in the two fluid collections. By demonstrating the presence of internal blood flow in solid tumors, color Doppler sonography can rapidly confirm the solid nature of markedly hypoechoic malignant tumors that mimic fluid collections on conventional sonograms.

Adult↗

Muscular trauma.

Explore the source record for details and available documents.

Athletic Injuries↗

Soft-tissue masses.

Explore the source record for details and available documents.

Connective Tissue Diseases↗

Complications and failures of subclavian-vein catheterization.

BACKGROUND: Although catheterization of the subclavian vein is a common procedure, the risk factors for complications and failures, with the exception of the physician's experience, are poorly understood. Ultrasonography has been recommended to help guide the placement of central venous catheters. METHODS: We conducted a prospective randomized trial of ultrasound-guided location of the subclavian vein as compared with standard insertion procedures. In the group of patients undergoing catheterization with ultrasound guidance, the site of the insertion was marked before the catheterization attempt; real-time ultrasound guidance was not used. The 821 eligible patients (411 in the ultrasound group and 410 in the control group) underwent catheterization in a single procedure suite under controlled nonemergency conditions, in most cases for the administration of chemotherapy. RESULTS: Ultrasound guidance had no effect on the rate of complications or failures of subclavian-vein catheterization (risk ratio for complications, 1.00; 95 percent confidence interval, 0.66 to 1.52; risk ratio for failures, 1.04; 95 percent confidence interval, 0.72 to 1.50). In multivariate analyses, prior major surgery in the region (P = 0.002), a body-mass index (the weight in kilograms divided by the square of the height in meters) higher than 30 or lower than 20 (P = 0.009), and previous catheterization (P = 0.043) were associated with failed attempts. Complications were also associated with failed attempts: 52 of the 721 patients (7.2 percent) in whom catheterization was successful had complications, as compared with 28 of the 100 patients (28 percent) in whom physicians were unable to place catheters. The number of needle passes was strongly associated with the rates of failure and complications. The complication rate rose from 4.3 percent with one pass to 24.0 percent with more than two passes. CONCLUSIONS: Ultrasound guidance of subclavian-vein catheterization, as used in this study, was not beneficial. In patients at highest risk for complications and failures, catheterization should be attempted by the most experienced physicians available.

Body Mass Index↗

Tubular carcinoma of the breast: cytologic features in fine-needle aspirations and application of monoclonal anti-alpha-smooth muscle actin in diagnosis.

Twenty fine-needle aspirations (FNAs) of histologically proven tubular carcinoma of the breast (TCB) were reviewed, and the staining distribution of alpha-smooth muscle actin (SMA) was evaluated to see if this improved FNA sensitivity. In 18 cases, the aspirates were cellular, consisting predominantly of epithelial cells arranged in cohesive tubular structures that appeared angular or twisted. Single epithelial cells were present in varying numbers in 14 cases (70%). Cribriform fragments corresponding to in situ ductal carcinoma were noted in 9 cases (45%). Individual, bare nuclei were present in seven cases (35%). The initial cytologic diagnoses were 10 carcinomas, eight suspicious for carcinoma, and two cases were misinterpreted as fibroadenoma. In 8 of 14 cases, the epithelial fragments stained negatively for SMA, whereas in six cases some fragments (< 10%) stained positively. These findings were in contrast to a reticulated staining pattern noted in almost all of the epithelial fragments in nine fibroadenomas and three fibrocystic changes. Eighteen well-differentiated invasive ductal carcinomas stained negatively, whereas four had occasional positively staining fragments. We conclude that TCB displays distinct cytomorphologic features that can be recognized or at least suggested by FNA. Awareness of the cytologic characteristics--angulated tubular structures with or without single epithelial cells--coupled with mammographic/ultrasound findings, is necessary to avoid a misdiagnosis. Alpha-smooth muscle actin staining may help in selected cases.

Actins↗

Ultrasound-guided fine-needle aspiration of nonpalpable breast lesions. Cytologic and histologic findings.

Between 1989 and 1992, 651 nonpalpable breast lesions in 586 patients were aspirated using the ultrasound-guided technique at M.D. Anderson Cancer Center. Cytologic diagnoses were as follows: malignant, 167; suspicious, 30; benign, 211; cysts, 168; atypical ductal hyperplasia, 4; and insufficient for diagnosis, 71. In all cystic and most benign lesions, fine-needle aspiration (FNA) confirmed the benign clinical findings, and surgery was not performed. Of the 483 solid lesions, 254 were subsequently treated surgically, either because of suspicious mammographic or sonographic findings or because of positive or suspicious cytologic findings. The cytologic diagnoses in these cases were as follows: 132 (52%) malignant, 65 (25%) benign, 26 (10%) suspicious, 4 (2%) atypical, and 27 (11%) insufficient for diagnosis. The sensitivity of ultrasound-guided FNA for the diagnosis of malignant lesions was 91%, specificity 77%, and overall accuracy 84%. There were four (2%) false-negative results. Diagnostic failures were attributed to the small size of the lesions, histologic type, and inexperience in localization and cytologic interpretation of tubular carcinoma. One (1%) false-positive diagnosis was made (atypical ductal hyperplasia misdiagnosed as carcinoma). The authors' findings indicate that ultrasound-guided FNA offers a reliable and simple alternative to open biopsy of nonpalpable breast lesions. The efficacy of this technique depends primarily on accurate localization of the biopsy needle and on skillful cytologic interpretation of certain breast lesions.

Biopsy, Needle↗

Masses in breasts with implants: diagnosis with US-guided fine-needle aspiration biopsy.

PURPOSE: To evaluate retrospectively the findings at ultrasound (US)-guided fine-needle aspiration biopsy (FNAB) of masses in breasts that contain a prosthesis. MATERIALS AND METHODS: Real-time US-guided FNAB was performed in 22 lesions in 17 patients with breast implants. Pneumocystography was performed in seven of eight cysts. The final diagnosis was based on either histologic findings after surgical excision or a combination of cytologic, imaging, and clinical findings. RESULTS: The lesions had a mean diameter of 15 mm +/- 9 (standard deviation). Fifteen lesions (68%) were not identified on mammograms. In all cases, FNAB was completed without complication. Pneumocystography was successful in seven of seven cysts. Cytologic diagnosis was correct in 21 of 22 lesions (95%). There was one case of inadequate specimen (5%). In 16 cases (73%), the diagnosis was established with a single pass. CONCLUSION: Real-time US allowed continuous visualization of the needle during insertion and sampling, which resulted in pinpoint accuracy and safety. US-guided FNAB is recommended for needle biopsy in breasts with implants.

Adult↗

Localization of impalpable breast masses: value of sonography in the operating room and scanning of excised specimens.

OBJECTIVE: Despite the variety of techniques available, mammographically guided preoperative localization of impalpable masses in the breast can be a difficult procedure for radiologists. Furthermore, in a few cases, an impalpable lesion is clearly seen on sonograms and yet poorly seen or not visible on mammograms. Accordingly, we studied the value of localizing impalpable masses with sonography in the operating room and of scanning excised specimens to confirm successful removal of the mass. All of the lesions were visible on preoperative sonograms. SUBJECTS AND METHODS: Twenty-six patients had sonographic examination of the breast in the operating room to guide the localization of an impalpable mass previously seen on sonograms. In eight patients, the lesion was poorly seen or not seen on conventional mammograms. Localizing techniques included one or more of the following: insertion of a needle, injection of dye, or simple marking on the skin. In 18 cases, sonography of the freshly excised specimen was done in the operating room. The sizes of the masses (13 fibroadenomas, 10 carcinomas, two cysts, and one tubular adenoma) measured on the sonograms ranged from 0.6 to 2.7 cm (mean +/- SD, 1.2 +/- 0.5 cm). RESULTS: In all 26 cases, the mass was clearly identified on sonograms obtained in the operating room. In all 18 cases in which it was used, sonography of the specimen correctly showed the presence or absence of the lesion. In two cases, sonographic determination of the absence of the lesion in the specimen prompted immediate reexcision, which was successful. CONCLUSION: Our experience shows that sonography in the operating room is a rapid and efficient method of localizing impalpable breast masses that have been seen on sonograms. Sonography of the specimen can indicate within seconds whether the excision has been successful. This technique is particularly valuable for masses that are not visible or only poorly visible on mammograms.

Breast↗

Intramuscular myxoma: sonographic appearance and sonographically guided needle biopsy.

The sonographic appearances of four intramuscular myxomas were reviewed. These tumors appeared as well-defined, ovoid masses surrounded by normal muscle. The echogenicity was decreased in all cases, and the presence of small fluid-filled clefts and cystic areas was noted in three of the four lesions. Color Doppler examination was performed in two cases and was negative. Sonographically guided fine-needle aspiration biopsy yielded a thick myxoid substance. Large-core cutting needle biopsy allowed establishment of the diagnosis in one of the two cases in which it was performed. The differential diagnosis of a well-demarcated intramuscular mass with multiple fluid-filled clefts or cystic areas should include intramuscular myxoma.

Biopsy, Needle↗

The detection of breast cancer after augmentation mammaplasty.

Thirty-five patients treated for 37 cases of breast cancer after augmentation mammaplasty were analyzed. All augmentations were performed with silicone gel prostheses at a mean age of 38 years (range 24 to 59 years). The mean interval from breast augmentation to the detection of breast cancer was 7.5 years. Physical examination demonstrated a palpable breast mass in 35 of the 37 cases (95 percent). The pathologic staging was in situ 3 (8 percent), local 18 (49 percent), and nonlocal 16 (43 percent). Standard compression mammography was performed in 31 patients prior to breast biopsy. Abnormalities were detected in 17 (54.8 percent). Palpable masses were visualized in only 12 (38.7 percent). Ultrasound was utilized successfully in 3 patients with palpable masses to guide fine-needle aspiration biopsy. Standard two-view mammography has a low sensitivity in detecting palpable cancers in patients who have undergone augmentation mammaplasty. Ultrasound should be evaluated as a routine adjunctive screening method in this group of patients. The clinical detection of breast cancer, as evidenced by pathologic staging, is not delayed.

Adult↗

Imaging of the skin with 20-MHz US.

PURPOSE: The authors clinically evaluated a new high-frequency ultrasound (US) scanner to determine the value of US for dermatologic applications. MATERIALS AND METHODS: A 20-MHz US scanner was used to visualize normal skin at eight sites in 10 healthy volunteers and to evaluate 200 skin lesions (45 malignant, 155 benign). RESULTS: In normal skin, the dermis was markedly echogenic and sharply demarcated from hypoechoic subcutaneous fat. The epidermis was not resolved except on the palm and sole. Only three superficial lesions were not identified with US; evaluation of another three was limited by shadowing. Thickness of the lesions visualized was 0.2-26.0 mm (mean, 1.9 mm +/- 2.6). Most lesions (77%) were hypoechoic, 9% were anechoic, 12% had mixed echogenicity, and 2% were isoechoic or hyperechoic. CONCLUSION: The diagnostic role of high-frequency US appears limited. It did not help differentiate benign from malignant lesions, but it did enable accurate delineation of deep margins of lesions and allowed noninvasive measurement of thickness. These features may help in the preoperative evaluation of skin tumors and in monitoring the response to therapy for certain inflammatory conditions.

Adolescent↗

Sonography of the skin and subcutaneous tissues.

Recent developments in US instrumentation, in particular the advent of 20-MHz transducers, have made B-mode US imaging of the skin feasible. Various pathologic conditions of the skin, mainly tumors and inflammatory diseases, can now be visualized, measured and monitored. The widely available 7.5- and 10-MHz transducers are adequate for the examination of subcutaneous tissues. The knowledge of the normal anatomy of skin and subcutaneous tissues helps diagnose such pathologic conditions as epidermoid and sebaceous cysts, benign and malignant tumors (nevi, hemangiomas, dermatofibromas, melanomas, lipomas, angiomas and angiosarcomas), inflammatory processes (inflammatory dermatoses, panniculites), traumas and foreign bodies. US was also used to measure subcutaneous fat thickness, especially in malnutrition, diabetes mellitus and acromegaly or in the patients treated with pentoine. Finally, US was employed to guide the needle into the veins of the patients with diffuse edema. Thanks to its excellent spatial resolution and cost-effectiveness, high-resolution US is expected to be used more extensively in the evaluation of skin and subcutaneous tissues.

Cysts↗

Sonography of peripheral nerves of the extremities.

High-resolution sonography can visualize segments of the major nerve trunks in the extremities, with nerves displaying a characteristic hyperechoic appearance. Sonography can also establish the diagnosis of nerve sheath tumors when the normal nerve is visualized. Other abnormalities that can be demonstrated by sonography include traumatic and Morton's neuromas and inflammatory changes. High-frequency probes up to 20.0 MHz are used. Both longitudinal and tranverse scans must be performed, strictly parallel and perpendicular to the nerve axis. In the upper extremities US demonstrates better than CT and MRI the radial and ulnar nerves in the elbow, the median nerve in the forearm and the carpal tunnel; in the lower extremities the sciatic, the tibial, the popliteal nerves are visualized, while both the deep and the superficial nerves are poorly demonstrated. Our experience leads us to the conclusion that the examination of nerves in the extremities is a promising new application of high resolution US. Indeed, the method can play a significant role in the diagnosis of pathologic conditions of nerves, particularly nerve sheath tumors, at a lower cost than MRI. However, the latter will remain the diagnostic procedure in areas of complex anatomy.

Humans↗

Ultrasound-guided needle biopsy of the breast and other interventional procedures.

The techniques of and indications for ultrasound-guided needle biopsy of nonpalpable breast lesions are described. High-frequency ultrasonography offers several distinct advantages over sterotaxy and is the technique of choice for guiding the drainage of cysts and fluid collections and the biopsy of any solid mass that can be identified on sonograms. Ultrasonography also can be used for localizing such lesions preoperatively.

Biopsy, Needle↗

Sonographic appearances of superficial soft tissue lipomas.

High-resolution real-time sonography was used to evaluate 35 superficial soft tissue lipomas. Thirty were located in subcutaneous tissues and 5 in superficial muscles. The lipomas were assessed for location, shape and size, boundaries, echotexture, homogeneity, and sound through transmission. All were elongated, with their greatest diameter parallel to the skin. Twenty-three lipomas (66%) showed a homogenous echotexture. Twenty-one (60%) were well defined, and the remainder showed ill-defined margins blending into the surrounding tissues. Twenty-nine percent of the lipomas were hypoechoic, 22% were isoechoic, 29% were hyperechoic, and 20% showed a mixed pattern. An elongated isoechoic or echogenic mass in the subcutaneous tissues should suggest the diagnosis of lipoma.

Adolescent↗