Evaluation of biopsy needles and prototypic needle guide devices for percutaneous biopsy with CT fluoroscopic guidance in simulated organ tissue.

The authors evaluated accuracy and success rates for placement of fine-aspiration, core, and coaxial biopsy needles in pork meat with three needle guide devices and computed tomographic fluoroscopic guidance. Accuracy and reliability with a metallic sponge-forceps needle holder was equal to or greater than those with other devices, and it was preferred by operators due to its lighter weight and single-handed manipulation. All needle holders functioned poorly with thin-walled needles.

Animals↗

Torsion of intraperitoneal renal transplants: imaging appearances.

OBJECTIVE: Torsion of a renal transplant is a rare complication with nonspecific clinical manifestations. Prompt detection is necessary to allow surgical treatment and to preserve renal function. We describe the radiologic appearances of torsion of intraperitoneal renal transplants in patients who have undergone simultaneous renal and pancreatic transplantation or dual renal transplantation. CONCLUSION: Renal transplant torsion should be suspected when a change in renal axis associated with abnormal perfusion occurs in an intraperitoneal kidney.

Adult↗

Bacterial loss from biofilms exposed to free chlorine.

Previous studies have demonstrated the increased resistance of biofilm bacteria to biocides when compared with freely suspended planktonic cells, but there have been few investigations of sloughing and losses from biofilms in response to biocide activity. A model biofilm system was used to demonstrate that the loss of sloughed bacteria (including Escherichia coli as a pathogen indicator organism) from actively growing biofilm reached levels of 10(6)-10(7) CFU ml-1 of eluted medium. The sloughing response was examined in response to a range of free chlorine concentrations from 0.6 to 5.0 mg l-1. While chlorine treatment greatly reduced bacterial sloughing, significant bacterial loss into the planktonic phase still occurred with free chlorine concentrations below 3.0 mg l-1, indicating active growth and sloughing of biofilm organisms. Exposure of the biofilm to higher levels of free chlorine resulted in inhibition of bacterial loss, though biocide removal was accompanied by a rapid, almost immediate, recovery of sloughing ability. This work demonstrates the endurance and speed of biofilm recovery upon quenching of chlorine residuals, highlighting a potentially significant public health risk from biofilm recovery and the sloughing of pathogenic organisms associated with the biofilm.

Actinomycetaceae↗

Care activities and outcomes of patients cared for by acute care nurse practitioners, physician assistants, and resident physicians: a comparison.

BACKGROUND: Little information is available on the practice of acute care nurse practitioners and physician assistants in acute care settings. OBJECTIVES: To compare the care activities performed by acute care nurse practitioners and physician assistants and the outcomes of their patients with the care activities and patients' outcomes of resident physicians. METHODS: Sixteen acute care nurse practitioners and physician assistants and a matched group of resident physicians were studied during a 14-month period. Data on the subjects' daily activities and on patients' outcomes were collected 4 times. RESULTS: Compared with the acute care nurse practitioners and physician assistants, residents cared for patients who were older and sicker, cared for more patients, worked more hours, took a more active role in patient rounds, and spent more time in lectures and conferences. The nurse practitioners and physician assistants were more likely than the residents to discuss patients with bedside nurses and to interact with patients' families. They also spent more time in research and administrative activities. Few of the acute care nurse practitioners and physician assistants performed invasive procedures on a regular basis. Outcomes were assessed for 187 patients treated by the acute care nurse practitioners and physician assistants and for 202 patients treated by the resident physicians. Outcomes did not differ markedly for patients treated by either group. The acute care nurse practitioners and physician assistants were more likely than the residents to include patients' social history in the admission notes. CONCLUSIONS: The tasks and activities performed by acute care nurse practitioners and physician assistants are similar to those performed by resident physicians. However, residents treat patients who are sicker and older than those treated by acute care nurse practitioners and physician assistants. Patients' outcomes are similar for both groups of subjects.

Acute Disease↗

Clinical predictors of transvenous biphasic defibrillation thresholds.

Transvenous lead systems have become routine for defibrillator placement. However, previous studies of clinical predictors of an adequate nonthoracotomy defibrillation threshold (DFT) evaluated monophasic waveforms or more complex lead systems, including subcutaneous patches. Accordingly, this study is a prospective evaluation of the predictors of an adequate biphasic DFT in 114 consecutive patients undergoing cardioverter-defibrillator implantation with a single transvenous lead. For each subject, 38 parameters were assessed, including standard demographic, electrocardiographic, echocardiographic, and radiographic measurements. An adequate DFT (< or =20 J) was achieved in 92% of patients. Multivariable analysis revealed 2 independent factors predictive of a high threshold: echocardiographic measurements of left ventricular dilation (odds ratio = 0.16, 95% confidence interval 0.05 to 0.53, p = 0.003) and body size (odds ratio = 0.36, 95% confidence interval 0.17 to 0.73; p = 0.005). No patient with a normal left ventricular end-diastolic dimension had a high DFT, whereas 14% (9 of 66) of those with left ventricular dilation had elevated thresholds. When the DFT cutoff was lowered to 15 J, as is necessary with some downsized pulse generators, an adequate threshold was observed in 84% of patients and the same 2 independent predictors of high thresholds were found. These results indicate that an adequate transvenous DFT can be predicted from simple clinical parameters.

Aged↗

Clinical predictors of transvenous defibrillation energy requirements.

Nonthoracotomy and, more recently, transvenous lead systems have become routine for initial implantable cardioverter-defibrillator (ICD) placement. Previous studies of clinical predictors of nonthoracotomy defibrillation energy requirements evaluated multiple complex lead systems that included subcutaneous patches. However, the predictors of an adequate transvenous defibrillation threshold (DFT) have not been assessed previously. Accordingly, the present study is a prospective evaluation of DFT using a uniform testing protocol in 119 consecutive patients undergoing ICD implantation with a single transvenous lead. For each patient, 38 parameters were assessed including standard clinical, echocardiographic, and radiographic measures. An adequate monophasic DFT (< or =20 J) was achieved in 76% of patients. Multivariable analysis revealed 3 independent factors predictive of a high threshold: preoperative amiodarone use (odds ratio = 5.8, p < or =0.002), echocardiographic measures of left ventricular dilation (odds ratio = 0.47, p < or =0.005) and body size (odds ratio = 0.51, p < or =0.006). Patients receiving amiodarone who also had left ventricular dilation constitute a group at considerable (69%) risk for having a high DFT. In contrast, patients with neither of these risk factors have only an 11% chance of having a high threshold. We conclude that an adequate transvenous DFT can be predicted from simple clinical parameters.

Amiodarone↗

The Ly-6E.1 (Sca-1) gene requires a 3' chromatin-dependent region for high-level gamma-interferon-induced hematopoietic cell expression.

The Ly-6E.1/A.2 gene product recognized by the Sca-1 antibody has been found on murine hematopoietic stem cells and some hematopoietic precursors, T lymphocytes, and nonhematopoietic cell lineages, suggesting a complex array of gene regulatory elements. The ability to use the Ly6E.1/A.2 transcriptional regulatory elements to direct expression of heterologous genes will allow for the manipulation of these cells during development and in hematopoietic cell transplantations. To identify the elements necessary for high-level expression, we have made deletion constructs of Ly-6E.1 gene flanking regions containing DNase I hypersensitive sites, tested them for expression in hematopoietic cells, and have performed kinetic analyses to correlate the appearance of hypersensitive sites with gene transcription and protein expression. We show that a 3' region containing two DNase I hypersensitive sites at +8.7 and +8.9 kb is required for high-level, gamma-interferon (gamma-IFN)-induced expression of the Ly-6E.1 gene and that a consensus sequence for a gamma-IFN-responsive element localizes to the +8.7 site. We also provide a description of allele- and cell-specific DNase I hypersensitive site patterns of the Ly-6E.1 and Ly-6A.2 genes. Taken together, these data indicate that while both 5' and 3' hypersensitive sites are rapidly induced with gamma-IFN, the 3' most distal hypersensitive sites are involved in directing high levels of expression of Sca-1 in hematopoietic cells.

Animals↗

Metal-ion discrimination by phage T7.

The discovery of new metal-selective complexing agents may be facilitated by applying an in vitro selection strategy. Such a strategy was recently devised to identify and enrich populations of bacteriophage that rely on Mg(II)-, Zn(II)-, or Au(III)-selective stabilization for survival in the presence of denaturing urea. The potential for extension of the strategy to other metal ions is investigated here. The kinetics of phage inactivation in 5 M urea was measured for a spectrum of metals. At a concentration of 1 mM, Mg(II), Ca(II), Co(II), and Ni(II) were found to be the most stabilizing, followed by Cd(II), Cu(II), and Zn(II), respectively. K(I) had virtually no effect. In contrast, Al(III) and Au(III) significantly destabilized the phage, even at concentrations of 0.25 mM.

Aluminum↗

Surgical transfer of the sartorius muscle to the groin after lymphadenectomy or debridement: CT findings.

OBJECTIVE: We describe the CT findings of medial transfer of a sartorius muscle flap, which is done to protect the femoral blood vessels after radical inguinal lymphadenectomy for cancer or surgical debridement of infected femoral vascular grafts. MATERIALS AND METHODS: We reviewed the appearances and initial interpretations of 33 CT studies in 17 patients who underwent medial sartorius flap transfer after either (1) inguinal lymphadenectomy for melanoma or penile cancer or (2) debridement of infected groin wounds complicating vascular reconstruction of the femoral arteries. Muscle flap transfer was defined by the surgical record as either complete or incomplete. In complete sartorius muscle transfer, the proximal end of the muscle is dissected from the anterior superior iliac spine, rotated along its long axis, and sutured medially to the inguinal ligament. In incomplete transfer, the muscle it mobilized and stretched medially, and its medial border is fixed to the inguinal ligament and deep tissues. Clinical correlation and follow-up examinations were done for all patients, and CT reevaluation at intervals was done in nine patients. RESULTS: Complete sartorius flap transfer resulted in a mass anterolateral or anterior to the femoral vessels on postoperative CT scans in 20 studies; five of these masses were misinterpreted initially as possible recurrent metastatic lymphadenopathy, infection, or hematoma. Incomplete sartorius flap transfer resulted in bandlike stretching of the muscle over the femoral vessels in 13 studies. CONCLUSION: Medial transfer of the sartorius muscle causes a variable appearance of the groin on CT scans. The findings on CT scans after complete sartorius flap transfer should be distinguished from recurrent lymphadenopathy and from postoperative phlegmon or hematoma.

Debridement↗

Sonographic evaluation of acute pancreatic transplant rejection: morphology-Doppler analysis versus guided percutaneous biopsy.

OBJECTIVE: Despite the increasing success of pancreatic transplantation for diabetes, rejection remains the most common cause of graft loss. The purpose of this study was to correlate gray-scale sonographic morphology and Doppler resistive index (RI) with acute pancreatic transplant rejection as determined by percutaneous, sonographically guided biopsy of the pancreas. SUBJECTS AND METHODS: Fifty-one sonograms of 36 patients were correlated with sonographically guided biopsies performed for clinically suspected acute rejection. Sonographic studies consisted of gray-scale morphologic assessment of gland size, texture, marginal definition, peripancreatic fluid, and duct dilatation as well as measurement of the average Doppler RI. Biopsies were performed within 48 hr of sonography. After localization by sonography, we performed percutaneous biopsy with an 18-gauge automated biopsy device. RESULTS: Biopsy findings were acute rejection (n = 40, 78%), chronic rejection (n = 2, 4%), and no evidence of rejection (n = 9, 18%). Procedure-related hemorrhage occurred in one patient and resolved spontaneously. Gray-scale sonographic abnormalities were present in 37 studies (73%). The most common abnormality was pancreatic enlargement (n = 23) with a sensitivity and specificity of 58% and 100%, respectively, for acute rejection. Loss of marginal definition occurred in nine studies with a sensitivity and specificity of 15% and 73%, respectively, for acute rejection. An RI > or = 0.7 was found in 11 studies (22%) with a sensitivity of 20% and a specificity of 73% for acute rejection. CONCLUSION: For the diagnosis of acute pancreatic rejection, sonographically guided percutaneous biopsy is superior to gray-scale and spectral Doppler sonography. Sonographically guided percutaneous biopsy is a safe technique with a high success rate. Gray-scale and spectral Doppler sonography lack sensitivity, and a normal RI should not delay biopsy.

Acute Disease↗

Nonbiliary laparoscopic gastrointestinal surgery: role of CT in diagnosis and management of complication.

OBJECTIVE: Laparoscopic techniques are evolving for a wide range of surgical procedures outside the biliary tree. We describe the CT findings of important complications detected after nonbiliary laparoscopic gastrointestinal surgery and the role of CT in their management. MATERIALS AND METHODS: Over a 3-year period, 209 patients had nonbiliary gastrointestinal laparoscopic procedures (partial or total colectomy, splenectomy, Nissen fundoplication, lymph-node dissection, herniorrhaphy, appendectomy, and exploratory laparoscopy). Thirty-seven abdominopelvic CT studies were performed on 18 (9%) of these patients for complications after surgery. In all cases CT findings were reviewed and correlated with follow-up surgical, clinical, or interventional radiologic findings. RESULTS: Fourteen major complications were detected on CT in 12 of 18 (67%) patients who had undergone partial or total colectomy (6/25, 24%), splenectomy (4/41, 10%), appendectomy (1/15, 7%), or lymph-node dissection (1/43, 2%). These complications included seven abscesses (three of the splenic bed, two of the pelvis, one of the liver, and one of the abdominal wall). The remaining complications were four hematomas (two in the abdominal wall caused by trocar site bleeding, one intraperitoneal, and one retroperitoneal), one case of colon perforation, one case of pancreatitis, and one case of splenic infarction. Percutaneous abscess drainage was performed successfully in seven patients, using CT guidance in six. Six patients had negative CT studies. CONCLUSION: Major complications may occur after complex nonbiliary laparoscopic procedures and are probably related to lack of experience with new surgical techniques. In this study, such complications occurred most often after laparoscopic colectomy and splenectomy. CT valuable in their diagnosis and in the management of abscess collections.

Adult↗

Quality assurance for abdominal CT: a rapid, computer-assisted technique.

OBJECTIVE: Maintaining high standards in a large CT imaging department with multiple scanners, a large technical and clerical staff, and a rotating staff of radiologists is an ongoing challenge. We undertook a project to design and implement a simple, rapidly performed computer-assisted system of quality assurance (QA) for use in abdominal CT. In our project, we also analyzed the results of that QA system. MATERIALS AND METHODS: We graded 1810 abdominal CT studies done in a 50-week period, using a three-point scale to indicate the quality of the following five parameters of technical quality: IV contrast enhancement, oral contrast opacification, window settings and artifacts, conformity to radiologists' protocol, and completeness and accuracy of header and scout data. In addition, a parameter reflecting performance of the film library and clerical staff was similarly graded. To provide a measure of peer review for radiologists, any disagreements with prior CT study reports were recorded when comparison studies were reviewed in the process of CT interpretation. A commercially available spreadsheet and database software program was tailored to allow rapid, easily performed data entry and analysis. Tables and graphs showing performance of technologists and film library and clerical staff were generated. This customized program was made available on the radiology department computer network. Results generated by the program were further analyzed with linear regression models. RESULTS: Our QA system was successfully integrated into the routine operation of the abdominal CT division. During the first 11.5 months of operation, the system reflected improvement in each of the technical parameters with a statistically significant improvement in the combined average technical score (from 1.15 to 1.68 on a scale of 0-2; p < .0001). The "Throughout Speed/Old Exams" parameter for performance of the film library and clerical staff, which was analyzed separately from the technical parameters, also improved significantly (from 1.3 to 1.8; p < .02). Improvements were statistically significant, even when we controlled for potential variations in quality among different CT scanners and variations among the radiologists who rated the quality of the examination. Thirty-eight disagreements with previous scan interpretations (5% of all scan comparisons) were recorded for evaluation at peer review conferences. CONCLUSION: The ability to monitor performance continuously using a rapid, computer-assisted system has effected measurable improvement in our CT service. Technologist and film library and clerical staff performance improved for all parameters studied. Deficiencies were revealed and trends demonstrated. The QA system allowed us to identify disagreements in interpretation of CT examinations for subsequent peer review by radiologists. Our QA software program has been made available on the Internet as freeware to licensed Excel users via anonymous file transfer protocol at Internet Protocol 134.192.6.110.

Administration, Oral↗

Preparation and characterization of RNA standards for use in quantitative branched DNA hybridization assays.

RNA standards were developed for use in quantitative hybridization assays such as the Quantiplex HCV RNA Assay and Quantiplex HIV RNA Assay, which are based on branched DNA signal amplification. In vitro transcripts ranging in size from 0.5 to 9.4 kb were prepared and purified by phenol extraction following gel electrophoresis or column chromatography. Aliquots of the transcripts were digested to nucleosides and phosphate and then quantified by phosphate analysis against the U.S. National Institute of Standards and Technology phosphate standard. The quantitation was checked by OD260 and by either hyperchromicity or isotopic tracer analysis. The quantitation of each lot of RNA agreed within 20% by the three methods. The reproducibility of the methods was tested by preparing a total of 13 lots of standard RNAs. The average percentage full-length RNA of the 13 lots was 82%, with a range of 59 to 97%. The standard RNAs were used to test the ability of the branched DNA hybridization assay to quantify all target RNAs accurately regardless of size or slight variations in sequence. Standard Hepatitis C virus (HCV) RNAs of 1.3, 2.2, and 3.2 kb showed that size has no detectable effect on quantitation in the branched DNA hybridization assay. Three different lots of standard 3.2-kb HCV RNA were serially diluted and quantified over a thousand-fold range in the branched DNA hybridization assay. The average signal per attomole of target varied by less than 20% among the 3 lots. Standard HCV RNA transcripts were also prepared from clones of HCV subtypes 1b and 3a to study the effects of target sequence diversity and probe design on quantitation by hybridization.(ABSTRACT TRUNCATED AT 250 WORDS)

Base Sequence↗

The cost-effectiveness of a special care unit to care for the chronically critically ill.

To assess the relative value of healthcare programs, technologic innovations, and clinical decisions, policymakers are searching for ways to evaluate cost-effectiveness. What constitutes cost-effectiveness and how should it be measured? The authors discuss ways in which the cost-effectiveness of clinical programs can be measured and describes various methods of assessing both costs and effectiveness. Comparison of the cost-effectiveness of a nurse managed special care unit with that of traditional intensive care units illustrates some of these methods.

Chronic Disease↗