PubMed Health⌕ Search

Biomedical subjects

B E Pfingst

Publications and source records attributed to B E Pfingst.

At least 37 records · Page 2Linked to original sources

Effects of phase duration on detection of electrical stimulation of the human cochlea.

Detection thresholds for biphasic symmetric pulses were measured in fourteen human subjects implanted with the Cochlear Corporation Nucleus 22 Implant. The effects of phase duration on thresholds were studied using single pulses, and 500 ms pulse trains at 100 pps. Psychophysical detection thresholds decreased as a function of phase duration with a change in slope at approximately 0.5 ms/phase. Mean single-pulse and pulse-train slopes were -3.60 and -4.25 dB/doubling of phase duration for pulse durations of less than about 0.5 ms/phase. For pulse durations greater than 0.5 ms/phase, mean slopes were -5.71 and -7.54 dB/doubling for single pulses and pulse trains, respectively. Thresholds for pulse trains decreased as a function of stimulus duration for durations up to at least 300 ms, with the rate of decrease being dependent on the phase duration of the pulse. Effects of stimulus duration were greater for longer phase duration signals. We hypothesize that the longer phase duration pulses activate multiple spikes in a single fiber and/or more effective patterns of spikes across fibers, which may explain why slopes of psychophysical threshold functions are steeper than those of functions for single auditory nerve fibers for longer duration pulses. Thresholds were compared to respective speech perception scores (CID sentences) since thresholds for long phase duration signals have been shown previously to be correlated with nerve survival patterns, and nerve survival patterns may affect speech perception. Correlation coefficients ranged from -0.59 to -0.81, depending on stimulus parameters and subject selection.

Adult↗

Comparison of spectral and nonspectral frequency difference limens for human and nonhuman primates.

Difference limens for frequency were measured in normal-hearing human and nonhuman-primate (macaque) subjects. Stimuli were 1-kHz pure tones, containing both spectral and temporal cues, and 100-Hz sinusoidally amplitude modulated broadband noise (SAM noise), containing only temporal (nonspectral) cues. Subjects were tested for a minimum of 20 sessions and until difference limens were stable over time for each stimulus at each of several sensation levels. Difference limens for pure-tone stimuli showed almost no overlap between human and nonhuman-primate subjects. Difference limens for SAM-noise stimuli for human and nonhuman-primate subjects overlapped considerably. The correlations between performance for the pure-tone stimuli and performance for the SAM noise stimuli averaged 0.60. These data suggest that at least two factors influence pure-tone frequency discrimination. One factor is dependent on the presence of place mechanisms while the other factor, or group of factors, seems to influence both spectral and nonspectral frequency discrimination.

Acoustic Stimulation↗

Stimulus features affecting psychophysical detection thresholds for electrical stimulation of the cochlea. II: Frequency and interpulse interval.

Psychophysical detection thresholds for electrical stimulation of the cochlea were measured in nonhuman primates (macaques) as part of a series of experiments exploring the stimulus features affecting detection. The monkeys were trained psychophysically using operant conditioning. One ear was treated with neomycin to destroy hair cells, and implanted with electrodes in the scala tympani and/or the cochlear wall. In experiment 1, detection thresholds were measured for trains of fixed-duration pulses and for sinusoids. For long-duration pulses (1 to 2 ms/phase), thresholds decreased as a function of frequency (pulse rate), reaching a minimum at a frequency between 125 and 210 pps, then increased as frequency was further increased. For shorter duration pulses, thresholds usually decreased monotonically as a function of frequency but sometimes showed a slight increase as a function of frequency near the highest frequencies tested. Typically slopes of the threshold versus frequency functions for fixed-duration pulses were equal to or less than slopes of threshold versus frequency functions for sinusoidal signals, where frequency and phase duration covaried. Additional observations on two of the cases were made in experiments 2 and 3. In experiment 2, thresholds for pairs of pulses were measured as a function of interpulse interval. Thresholds decreased as a function of interpulse interval up to intervals of 2 to 4 ms and then increased slightly. In experiment 3, thresholds were measured as a function of stimulus duration at two frequencies.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Cochlear wall titanium implants for auditory nerve stimulation.

Genetically deaf dalmatian dogs and ototoxically deafened macaque monkeys were implanted with electrodes housed in cochlear wall titanium implants to assess long-term stability, tolerance, and performance. Short-term human implantation, followed by trials of stimulation, was performed in 4 unilaterally deaf patients. In the dog experiments, cochlear wall electrode stimulation produced consistent electrophysiologic thresholds that were higher, by approximately 6 dB, than those obtained with bipolar scala tympani stimulation. Clinical testing revealed electrically evoked middle latency response, auditory brain stem response, and/or behavioral detection responses in 3 of 4 patients, at levels below those for facial nerve activation and pain sensation. Electrode place discrimination studies, with controls for loudness cues, revealed near-perfect discrimination in a monkey subject. Eleven of the 12 animal implants were found to be rigidly fixed in the cochlear bone, with direct contract between bone and implant over 8% to 23% of the implant surface for the 6 implants examined in detail. These results suggest that long-term fixation of titanium cochlear wall implants occurs by virtue of intimate implant-bone contact in restricted areas. This approach to prosthetic stimulation demonstrates encouraging performance characteristics in achieving auditory activation.

Acoustic Stimulation↗

Electrical stimulation of the auditory nerve: effects of pulse width on frequency discrimination.

Effects of pulse width on discrimination of simultaneous changes in frequency and level of electrical pulse trains were studied in a monkey subject with a cochlear implant. At test-stimulus levels where performance was minimum, frequency difference limens were larger for longer-duration pulses than that for shorter-duration pulses. Several factors may have contributed to these differences.

Animals↗

Stimulus features affecting psychophysical detection thresholds for electrical stimulation of the cochlea. I: Phase duration and stimulus duration.

The shapes and levels of psychophysical detection threshold versus frequency functions for sinusoidal electrical stimulation of the deafened cochlea vary from subject to subject. These variations have been shown previously to be correlated with nerve-survival patterns. The shapes of these functions are critical in the design and calibration of analog processors for auditory prostheses. This paper examines two stimulus features that may contribute to the shapes of these functions: phase duration and stimulus duration. Psychophysical experiments were performed with unilaterally deafened and implanted macaque monkeys. Effects of phase duration were studied by measuring thresholds for single symmetric biphasic pulses presented at a rate of 1 per trial. Psychophysical detection thresholds for these pulses decreased, in the region of maximum slope, at a rate averaging -6.2 dB per doubling of phase duration, which is steeper than the rate of decrease in thresholds reported for single auditory-nerve fibers. Slope was weakly correlated with threshold level. Thresholds for long-duration sinusoids were consistently lower and the slopes of the threshold versus phase-duration functions were consistently steeper than those for single pulses. Thresholds for sinusoids and pulse trains decreased as a function of stimulus duration for durations up to at least 300 ms. The rate of decrease as a function of stimulus duration depended on the phase duration of the stimulus, and for long phase-duration signals, it depended on frequency. The rate of decrease was correlated with the absolute-detection-threshold level. We conclude that phase duration contributes significantly to, but does not completely account for, the steep slopes of the threshold versus frequency functions for long-duration sinusoids. Temporal integration is greater for longer phase-duration signals, giving rise to steeper slopes of threshold functions for long-duration sinusoids as compared to those for single pulses in the 1- to 5-ms/phase range. Current neural data and models do not account for the steep slopes of psychophysical threshold functions.

Animals↗

Effects of level on nonspectral frequency difference limens for electrical and acoustic stimuli.

The purpose of this experiment was to study the effects of stimulus level on discrimination of frequency as represented in the temporal waveforms of acoustic and electrical signals. The subjects were four nonhuman primates in which one ear had been deafened and implanted with an electrode array and the other ear was untreated. Frequency difference limens for 100 Hz electrical sinusoidal stimulation via a cochlear implant in the deafened ear were compared to those for 100 Hz sinusoidally amplitude-modulated white noise (SAM noise) acoustic stimuli to the normal-hearing contralateral ear. To correct for loudness cues, levels of the test stimuli were varied relative to the reference-stimulus level. The test-stimulus levels at which the percent responses were minimum were determined. These levels were used to measure the frequency difference limens. Frequency difference limens for the electrical stimuli decreased as a function of reference-stimulus level through most of the dynamic range, while those for the acoustic stimuli reached a minimum at 20 dB to 40 dB above threshold. For the electrical stimuli the slopes and relative positions of the frequency difference limen vs. level functions varied from subject to subject, and with changes in electrode configuration within a subject. These differences were related to threshold level and dynamic range. At higher levels of stimulation, frequency difference limens for acoustic and electrical stimuli fell in the same range. The slopes and relative positions of the frequency difference limen vs. level functions for electrical stimuli did not parallel those of level difference limen vs. level functions collected simultaneously from the same ears. The data suggest that nonspectral frequency discrimination may depend on the number of nerve fibers stimulated. With prostheses in cochleas with less than a full complement of auditory nerve fibers, the data suggest that stimulation level is an important variable influencing discriminability.

Acoustic Stimulation↗

Changes over time in thresholds for electrical stimulation of the cochlea.

The purpose of this paper is to better characterize changes over time that occurred in psychophysical detection thresholds for electrical stimulation of the cochlea. Threshold changes observed in nonhuman primates implanted with cochlear electrode arrays can be divided into at least three types based on the patterns of change over time. Short-term increases and subsequent decreases in threshold were commonly observed during the first months after implantation and were often followed by periods of long-term threshold stability. Long-term slow increases in thresholds and more rapid increases after a period of threshold stability have also been observed. The threshold changes may be divided into at least two classes based on their dependence on the waveforms used for the threshold measurements. Some changes occurred primarily in thresholds for long phase-duration signals while other changes were equal in magnitude (in decibels) for all tested stimuli. This suggests that at least two mechanisms underlay these threshold changes. The observed changes in thresholds have implications for experimental studies of electrical stimulation and for clinical application of auditory prostheses.

Animals↗

Inner ear implants for experimental electrical stimulation of auditory nerve arrays.

Electrode arrays chronically implanted in the inner ear are gaining increased use for experimental studies of the auditory nervous system, as well as for studies related to development of improved auditory prostheses. Commercially available electrode arrays are designed for human use and thus may be unsuitable for experimental studies, particularly in small animals. This paper describes a simple, inexpensive method for making custom electrode arrays in a variety of configurations, suitable for animals ranging from small rodents to non-human primates.

Animals↗

Chronic skull-anchored percutaneous implants in non-human primates.

Three groups of chronic, skull-anchored, percutaneous implants differing in materials, design and surgical procedures used for implantation, were tested in macaque monkeys in conjunction with studies of an inner ear stimulation device. Implants from the first two groups in which high-speed drilling methods and stainless steel materials were used, showed a high percentage of failures during the first 3 months after implantation of the percutaneous connector. Implants in the third group, in which measures were taken to preserve living bone tissue, all survived for greater than 7 months. Probable factors relating to implant survival are care of the bone during surgery, postsurgical mechanical trauma, materials and other details of the surgical procedure.

Animals↗

Comparisons of psychophysical and neurophysiological studies of cochlear implants.

This paper compares psychophysical and neural studies of electrical stimulation of the auditory nerve with the goal of evaluating the relevance of single-unit animal models for the development of cochlear prostheses for profoundly deaf humans. Comparative psychophysical studies with implanted deaf subjects indicate that animal models, at least nonhuman primates, provide a close match to humans, though this is not always true for acoustic stimulation of normal-hearing subjects. However, the human-animal comparisons, especially those involving electrical stimuli, need further study using more carefully matched conditions. Comparisons of psychophysical and neurophysiological thresholds for electrical stimulation in animals reveal consistently higher thresholds in the neural studies. A number of factors which may account for these differences are discussed. A partial resolution of the problem could result from conducting neurophysiological and behavioral studies in the same animal. Finally, comparison of psychophysical and neurophysiological studies of temporal encoding suggest that there may be more information encoded in the auditory nerve than is used by the system, at least for nonspectral frequency discrimination. This points to a need for further analysis of the processing of this information at higher levels in the auditory pathway.

Animals↗

Titanium implants in the otic capsule: development of a new multichannel extracochlear implant.

Preliminary data are presented on the development of a new approach for multi-channel stimulation of the cochlea. The approach is based upon the use of small titanium implants in the lateral wall of the inner ear which act as anchor points for platinum-iridium stimulating electrodes. These holders allow contact of the stimulating electrode with the lateral surface of the membranous labyrinth. Observations in monkeys indicate that some degree of anchoring of the titanium implant in the otic capsule is achievable, including the formation of a close bone-metal interface. We propose that this approach may yield an alternative strategy for the development of a multichannel extracochlear prosthesis.

Animals↗

Stimulation and encoding strategies for cochlear prostheses.

This article reviews the various stimulation and encoding strategies currently used in hearing prostheses for profoundly deaf individuals. Various designs for implanted electrode arrays, electrode drivers, and systems for transmitting signals are described. The various strategies for encoding acoustic signals for delivery as electrical stimuli to the auditory nerve are reviewed. Finally, applications of these various stimulation and encoding strategies are described using examples from different groups worldwide which have developed their own unique prosthetic devices.

Cochlear Implants↗

Operating ranges and intensity psychophysics for cochlear implants. Implications for speech processing strategies.

This report reviews human and monkey psychophysical data related to the detection and perception of intensity information by subjects with cochlear implants. The threshold contour for sinusoidal stimuli is characterized by a slope near zero at frequencies below about 100 Hz, a slope of 5 to 15 dB per octave at frequencies from about 100 Hz to between 0.2 and 2.0 kHz, and a slope of 4 dB per octave at higher frequencies. Equal loudness (or latency) contours follow the threshold contour at low intensities but change gradually as intensity is increased, assuming a shape that can be characterized by zero slope below 100 to 250 Hz and a 3-dB-per-octave slope at higher frequencies. Loudness growth functions and intensity difference limens are also dependent on stimulus frequency and intensity. These psychophysical data suggest that membrane characteristics and other factors impose marked alterations on incoming electrical stimuli, which must be considered carefully when developing speech encoding strategies.

Acoustic Stimulation↗

Effects of reaction time performance on single-unit activity in the central auditory pathway of the rhesus macaque.

The activity of single units at various locations in the central auditory pathway of rhesus macaques was recorded during the monkeys' performance and nonperformance in an auditory reaction time task. Evoked unit responses during performance were compared with those observed during passive delivery of identical stimuli. Single units were recorded from the cochlear nucleus, superior olivary complex, lateral lemniscus, inferior colliculus, medial geniculate nucleus, and auditory cortex. Significant effects of task performance on unit discharge patterns were observed at all levels of the central auditory pathway: Spontaneous discharge rates in the more peripheral auditory nuclei tended to be higher during performance. Evoked discharge that occurred relatively late during a stimulus presentation (greater than 75 msec after stimulus onset) was increased during performance, compared with the nonperformance condition, in nuclei above the cochlear nucleus. The initial latency of evoked discharge was increased during performance for subcortical nuclei but was decreased for units in auditory cortex. These results suggest that the effects of performance may be mediated by a tonic increase in the excitability of auditory units which operates primarily at peripheral auditory stations, and a descending, stimulus-evoked increase in excitability which primarily influences the cells of higher auditory nuclei. At the cortical level, these changes lead to increased signal-to-noise ratio of the evoked response during performance in the auditory task.

Acoustic Stimulation↗