Intensity discrimination with cochlear implants.

Intensity difference limens were measured for various frequencies and intensities of sinusoidal and pulsatile electrical stimulation in monkeys with electrodes implanted in the scala tympani, scala vestibuli, modiolus, or middle ear. Difference limens decreased, as a function of initial stimulus intensity, from values of 1.5-3 dB near threshold to as low as 0.5 dB near the upper limit of the dynamic range. If sensation level was held constant, difference limens decreased as a function of frequency up to about 500 Hz, and then remained constant. They were similar across a variety of electrode placements and separations if differences in threshold and dynamic range were taken into account. However, difference limens measured in severely damaged ears were slightly smaller than those in moderately damaged ears. The near miss to Weber's law, characteristic of acoustic difference limens, was not seen with electrical stimuli. Differences limens for electrical stimuli were roughly one-half those for acoustic stimuli; thus, part of the deficit in dynamic range for electrical stimulation compared with acoustic stimulation is countered by the smaller intensity differences limens for electrical stimuli.

Acoustic Stimulation↗

A vertical stereotaxic approach to auditory cortex in the unanesthetized monkey.

A procedure is described for chronic single-unit recording from monkey auditory cortex. The cortex is approached in a vertical stereotaxic plane and subsequent histology is performed on tissue sections made in the same plane. The procedure maximizes the probability of locating and identifying auditory cortical areas during the chronic unit recording sessions and of identifying individual electrode tracks in subsequent histologic examination. Average stereotaxic coordinates for the center of area A1 are A-P +5, M-L 17.5 and D-V +20, but variation of +/-5 mm can occur across subjects. The superior temporal plane is sloped at an angle of about 30 degrees in the A-P dimension but is relatively flat in the M-L dimension. Microelectrode penetrations made with this procedure were found, on the average, to terminate within 0.7 mm of the intended site. Procedures for improving this accuracy and for identifying closely-spaced penetrations are discussed.

Animals↗

Electrophysiologic studies of the auditory cortex in the awake monkey.

An overview of some recent developments in the study of central auditory processes is presented. We describe findings from single cell physiologic studies that contribute to our understanding of central auditory function, the development of behavioral techniques permitting precise evaluation of hearing in animals, and the power and potential of integrative neurophysiologic-behavioiral investigations in defining and analyzing central neural mechanisms that underlie normal perception and imperception. The influence of changes in intermodality attention on evoked activity of 25 cells of the auditory cortex is described and compared to effects of other attentional changes. A small but consistent increase in excitatory cell evoked discharge rate and a reduction in initial latency of response are shown to be correlated with a shift from a visual to an auditory task. In general, behavioral states ranging from sleep-waking to attention to a specific acoustic cue are shown to influence responsiveness of the auditory system and variability of response. Procedures are described for effective control of attentional factors and reduction of electrophysiologic variability. The contributions of these data and procedures to studies of the encoding of complex auditory signals and studies of neural mechanisms underlying such disorders as noise induced hearing loss are discussed.

Animals↗

Pure tone thresholds for the rhesus monkey.

Auditory thresholds were measured for 18 ears from 13 rhesus monkeys using a simple reaction-time procedure. The threshold contour was a smooth W-shaped function with rises at the extreme frequencies and around 4 kHz and was comparable in shape with previously reported thresholds for this animal. Standard deviations averaged 5.3 dB.

Animals↗

Response plasticity of neurons in auditory cortex of the rhesus monkey.

Auditory-evoked responses in single neurons from rhesus monkey auditory cortex were measured under four relatively well defined behavioral and physiological conditions: (1) monkey awake and performing a simple auditory reaction time task; (2) monkey awake but not performing a task (Stage A); (3) monkey in a drowsy or Stage 1 sleep state (State B); and (4) monkey anesthetized with a short-acting nonbarbiturate anesthetic. For most units studied the response evoked by the auditory stimulus was greater in the performance condition than in the nonperformance condition. Similarly, evoked activity was usually greater in State A than in State B. Finally, evoked responses under anesthesia were usually weaker than those obtained in the unanesthetized animal. Some exceptions were noted in each case. Differences in response patterns and in rate versus intensity functions of neurons were also found to be associated with the behavioral and physiological state of the preparation. No significant changes in unit spontaneous activity associated with changes in behavioral or physiological condition were observed.

Acoustic Stimulation↗

Operant conditioning of single-unit response patterns in visual cortex.

Unit responses to photic stimuli were studied in cat visual cortex. After the baseline response pattern of a cell was determined, conditioning trials were given during which reinforcement was contingent upon increased firing during a selected segment of the poststimulus interval. Density of reinforcement increased substantially in about half the cells studied; significant increases in firing occurred within, but not outside, the criterion segment.

Animals↗

Psychophysical evaluation of cochlear prostheses in a monkey model.

Functional aspects of cochlear prostheses implanted in the scala tympani were tested in monkeys trained to perform a simple reaction-time task. Thresholds for detection of electrical stimulation and dynamic ranges were tested for a wide range of frequencies of sinusoidal stimulation and for biphasic rectangular pulses of various durations and repetition rates. The results are comparable with available data from implanted human patients and extend these findings, exploring various aspects of electrical stimulation in greater detail.

Acoustic Stimulation↗

Operating ranges for cochlear implants.

The range of simple electrical stimuli that may be used for prosthetic stimulation via scala tympani implants was explored using psychophysical procedures in macaque monkeys. Biophysical considerations placed further limitations on the operating range. The operating range was dependent onstimulus waveform, electrode configuration, and the condition of the implanted cochlea and eighth nerve.

Animals↗

Design of the cochlear prosthesis: effects of the flow of current in the implanted ear.

When structures within the temporal bone are stimulated electrically it is desirable to maximize the dynamic range of the stimulus. The maximum dynamic range of electrical stimulus seems to be found when the threshold of stimulation is minimum. The minimum threshold of stimulus is likely to be reached when the electrical current that flow through regions containing excitable cells is maximized. By implanting electrodes throughout the temporal bone, it is possible to apply electrical currents to the ear and to measure the distributions of current flowing within the ear. The results of these measurements demonstrate that when current flow is directed outside the scala tympani, lower thresholds can be obtained. Frequency dependence of the paths of current flow cannot be used to explain the frequency dependence of the frequency-threshold functions measured in animals.

Animals↗

Comparison of cochlear histopathology following two implant designs for use in scala tympani.

Two designs of intracochlear implants were evaluated for their histopathologic effects in the monkey ear. A molded electrode designed to fit the contour of the basal turn of the scala tympani tended to create basilar membrane fistulas and osseous spiral lamina fracture, along with relatively extensive loss of spiral ganglion cells in sites adjacent to the implant. A delicate, free-fit electrode induced local encapsulation but little or no mechanical damage and limited degeneration of spiral ganglion cells. Both electrode types occasionally induced changes in stria vascularis.

Animals↗

Cochlear prostheses: stimulation-induced damage.

The effects of 4 weekly, three-hour exposures to continuous sinusoidal (l kHz) electrical stimulation of the inner ear at various current levels were assessed in the chronically implanted guinea pig. With scala tympani stimulation, histopathological damage, including new bone growth, was observed for currents at and above 100 microA rms. No changes were observed in similarly implanted, but not stimulated cochleas. At equal current levels, less damage was found in subjects stimulated via electrodes placed on the round window and promontory, as compared to the scala tympani. Consistent reversible changes in threshold and suprathreshold features of the electrically evoked auditory brainstem response (EABR) were found. The magnitude of EABR change was directly related to exposure stimulus current level and to cochlear stimulation site. Suprathreshold features of the EABR were more sensitive to continuous stimulation exposures than threshold measures. Reversible EABR changes were found in the presence and absence of stimulation-induced histopathology.

Animals↗

Discrimination of complex electrical stimulation through a multichannel intracochlear implant.

A model has been developed to describe the electric fields generated in the inner ear when electrical stimuli are presented through a multichannel implant in the scala tympani of the cochlea. The model relies on the hypothesis that stimuli which excite the largest number of neural elements provide the greatest probability of successful discrimination by the implanted subject. It suggests that the effective stimulus is determined by the linear combination of electrical fields produced by the individual channels, and that excitation takes place in a spatially restricted area of the auditory nerve in the vicinity of the stimulating electrodes. The model was tested by biophysical measurements of the potential developed in the stimulated cochlea, and by a psychophysical study of the ability of a monkey to discriminate complex electrical signals using dual channel stimulation. The experimental findings are in agreement with the computer simulations.

Animals↗