Development of cochlear-wall implants for electrical stimulation of the auditory nerve.

The aim of these experiments was to investigate the use of titanium implants for anchorage of stimulating electrodes or other clinical or experimental devices in the bony wall of the cochlea. Twenty-six cylindrical titanium fixtures, 0.6 mm in diameter, were inserted into holes drilled in the otic capsule in 8 ears in 5 nonhuman primates and then examined for stability after periods of 2 months to 2 years. Following sacrifice, the bone-metal interfaces were examined microscopically. Fourteen of the implants were firmly fixed in the bone, 6 were loosely fixed and 6 came out. Poor fixation was associated with infection in the middle ear. In uninfected ears, 90% of the implants were stable. The implants were not osseointegrated in the classic sense, but in stable implants, direct bone contact covering 5 to 60% of the titanium oxide surface of the implant shaft was observed.

Animals↗

Biophysical measurements in the implanted cochlea.

Electrical stimulation via implanted electrode has been used to produce perceptions of sound in human subjects. This study describes preliminary work needed to understand the implanted ear and the distribution of current within it so that a stimulus system can be designed that is optimal for longevity, information transfer, and safety.

Animals↗

Tissue impedance and current flow in the implanted ear. Implications for the cochlear prosthesis.

Tissue impedance was measured in the cochleas of monkeys and guinea pigs implanted with electrode arrays. The impedances were measured within the scala tympani and between the scala tympani and the internal auditory meatus of the modiolus. The measurements revealed several impedance properties. 1) The impedances inside and outside of the scala tympani are resistive for frequencies between 8 Hz and 12.5 kHz. 2). The impedances measured between the scala tympani and the internal auditory meatus were larger in magnitude than the impedances measured in the scala tympani. 3) Impedance was not affected significantly by changing stimulus current flow from 0.45 to 45 microA rms. 4) Impedance magnitude increased rapidly by different factors inside and outside the scala tympani after sacrifice of the subject animals. Measurements of the tissue impedance made in conjunction with measurements of threshold of response to electrical stimulation revealed that the threshold of response to electrical stimuli was lowest when the stimulating currents were highest outside the scala tympani. We conclude that the excitable elements of the auditory nerve are being stimulated within the modiolus rather than within the scala tympani.