Aerobiology in the operating room and its implications for working standards.

Two novel operating room (OR) ventilation concepts, i.e. the upward displacement or thermal convection system and the exponential ultra-clean laminar air flow (LAF) designed to function without extra walls, were evaluated from a bacteriological point of view. The thermal convection system (17 air changes/h) was compared with conventional ventilation (16 air changes/h) with an air inlet at the ceiling and evacuation at floor level. The exponential LAF was compared with the vertical ultra-clean LAF and the horizontal ultra-clean LAF, both with extra side walls. The comparison was made using strictly standardized simulated operations and, except for the horizontal LAF, it was performed in the same OR where the type of ventilation was changed. In the different areas important for surgical asepsis, the thermal system resulted in a twofold to threefold increase in bacterial air and surface counts compared to the conventional system (statistical significance = p < 0.05-0.0001). The bacteriological efficiency of the exponential LAF was equal to the horizontal and vertical LAF units with extra walls in the OR, and all three systems easily fulfilled the criteria for ultra-clean air, i.e. bacteria-carrying particles < 10/m3. In the areas important for surgical asepsis the turbulent ventilation systems yielded highly significant correlation between air and surface contamination (p < 0.02-0.0006). No such correlation existed in the LAF systems.

Air Microbiology↗

The addition of a mobile ultra-clean exponential laminar airflow screen to conventional operating room ventilation reduces bacterial contamination to operating box levels.

A mobile screen producing ultra-clean exponential laminar airflow (LAF) was investigated as an addition to conventional turbulent/mixing operating room (OR) ventilation (16 air changes/h). The evaluation was performed in a small OR (50 m(3)) during 60 standardized operations for groin hernia including mesh implantation. The additional ventilation was used in 50 of the operations. The LAF passed from the foot-end of the OR table over the instrument and surgical area. Strict hygiene OR procedures including tightly woven and non-woven OR clothing were used. Sedimentation rates were recorded at the level of the patients' chests (N=60) (i.e. the air had passed the surgical team) and in the periphery of the OR. In addition bacterial air contamination was studied above the patients' chests in all 10 operations without the additional LAF and in 12 with the LAF. The screen reduced the mean counts of sedimenting bacteria (cfu/m(2)/h) on the patients' chests from 775 without the screen to 355 (P=0.0003). The screen also reduced the mean air counts of bacteria (cfu/m(3)) above the patients' chests from 27 to 9 (P=0.0001). No significant differences in mean sedimentation rates (cfu/m(2)/h) existed in the periphery of the OR where 628 without and 574 with screen were recorded. During the follow-up period of six months no surgical site infections were detected. In conclusion when the mobile LAF screen was added to conventional OR ventilation the counts of aerobic airborne and sedimenting bacteria-carrying particles downstream of the surgical team were reduced to the levels achieved with complete ultra-clean LAF OR ventilation (operating box).

Bacteria↗

Mobile zoned/exponential LAF screen: a new concept in ultra-clean air technology for additional operating room ventilation.

A mobile screen (0.5 x 0.4 m) producing ultra-clean exponential LAF (air-flow central zone 0.6 m/s and peripheral zone 0.4 m/s) was investigated as an addition to conventional turbulent/mixing operating room ventilation. The evaluation was performed during strictly standardized sham operations reflecting conditions during major surgery. The study consisted of a pilot experiment designed to give high counts of sedimenting aerobic colony forming units (cfu). In a second main study, recording dust particles, air-borne and sedimenting aerobic cfu, the screen was associated with optimal operating room clothing. In the pilot experiment the use of the screen resulted in a substantial reduction of sedimenting bacteria from 3835-4940 to 0-390 cfu/m(2)/h. In the main study, the use of the additional LAF reduced the surface contamination from 416-329 to 7-78 cfu/m(2)/h up to 1.6 m from the screen (P=0.001-0.0001). Measured in the wound area the screen reduced the air counts of bacteria from 9-14 to 0.2-0.4 cfu/m(3) (P=0.008-0.0001) and a marked reduction of air-borne dust particles was recorded (P=0.007-0.009). In conclusion, the additional mobile LAF screen reduced the counts of aerobic air-borne and sedimenting bacteria-carrying particles as well as dust particles to the levels gained with complete ultra-clean LAF room ventilation. Thus, the screen might prove a valuable addition to operating room ventilation as well as in other areas where asepsis is essential.

Air Microbiology↗

Surgical area contamination--comparable bacterial counts using disposable head and mask and helmet aspirator system, but dramatic increase upon omission of head-gear: an experimental study in horizontal laminar air-flow.

The effect of different head coverings on air-borne transmission of bacteria and particles in the surgical area was studied during 30 strictly standardized sham operations performed in a horizontal laminar air flow (LAF) unit. The operating team members wore disposable gowns plus either a non-sterile head covering consisting of a squire type disposable hood and triple laminar face mask, a sterilized helmet aspirator system or no head cover at all. In the wound area both types of head cover resulted in low and comparable air (means of 8 and 4cfu/m(3)) and surface contamination (means of 69 and 126cfu/m(2)/h) rates. Omission of head-gear resulted in a three- to five-fold increase (P > or = 0.01- 0.001), depending on site sampled air contamination rate (mean of 22cfu/m(3)) whereas the bacterial sedimentation rate in the wound area increased about 60-fold ( P > or = 0.0001). A proper head cover minimized the emission of apparently heavy particles that were not removed by the horizontal LAF and contained mainly streptococci, presumably of respiratory tract origin. Dust particle counts revealed no differences between the three experimental situations. No correlation between air and surface contamination rates or between air contamination and air particle counts was found. We conclude that, from a bacteriological point of view, disposable hoods of squire type and face masks are equally as efficient as a helmet aspirator system and both will efficiently contain the substantial emission of bacteria-carrying droplets from the respiratory tract occurring when head cover is omitted. Finally, the use of bacterial air counts to assess surgical site surface contamination in horizontal LAF units must be seriously questioned.

Air Microbiology↗

Brånemark implants and osteoporosis: a clinical exploratory study.

BACKGROUND: Oral implant treatment on patients with poor jaw-bone texture has shown increased failure rates in series of studies. PURPOSE: The purpose of the present study was to retrospectively follow patients with osteoporosis of the axial or appendicular skeleton, including the jaw bone, being subjected to oral implant treatment. The outcome of inserted implants, when using an adapted bone site preparation technique and extended healing periods, was evaluated. MATERIALS AND METHODS: Based on data obtained from preoperative radiographs, patient medical history, and resistance of the jaw bone perceived during drilling, 14 of 16 patients were referred to the Osteoporosis Laboratory, Sahlgren University Hospital, Göteborg, Sweden, for bone density measurements. Two patients already had an established diagnosis of osteoporosis. Fourteen jaws in 13 patients (11 females, 2 males; mean age: 68 yr) were subsequently subjected to oral implant treatment with a total of 70 implants (Brånemark System) of various designs. The mean follow-up period was 3 years and 4 months (range: 6 mo-11 yr). RESULTS: Osteoporosis of either the spine, the hip, or both regions was diagnosed in 14 patients, and osteopenia was diagnosed in 2 patients. Two implants failed, and the overall implant survival rate at the end of the study period was 97.0% for maxillae and 97.3% for mandibles. The marginal bone resorption at the 1-year follow-up concurs with the outcome of other studies, irrespective of the preoperative bone texture present. CONCLUSION: The outcome of the present study showed that implant placement in patients in whom the average bone density showed osteoporosis in both lumbar spine and hip as well as poor local bone texture may be successful over a period of many years.

Aged↗

Long-term follow-up of severely atrophic edentulous mandibles reconstructed with short Brånemark implants.

BACKGROUND: Oral implant treatment (Brånemark System) of edentulous mandibles has been presented in numerous studies. However, with regard to the severely atrophic lower jaw, no long-term follow-up studies with solely short implants are available. PURPOSE: The purpose of the present investigation was to retrospectively follow the long-term treatment outcome of patients with severely resorbed edentulous mandibles being subjected to oral implant placement with short (6-7 mm) Brånemark implants. MATERIALS AND METHODS: A total of 247 standard (7 mm long, Ø 3.75 mm) and 13 wide (6 mm long, Ø 5 mm) implants were inserted in 49 patients, all of whom exhibited severe resorption of edentate mandibles. Fixed implant-supported prostheses were manufactured for 45 patients, whereas 4 patients received overdentures. The patients were followed for a mean period of 8 years (range, 1-14 yr). RESULTS: Seventeen implants failed during the study period (cumulative implant survival rate 95.5% at 5-yr and 92.3% at 10-yr follow-up). Implant-supported constructions were worn continuously throughout the investigation by all study subjects. Marginal bone loss, measured after 1, 5, and 10 years of function, concurred with studies of Brånemark implants placed in more voluminous mandibles. No major clinical or construction complications occurred in the followed patients. CONCLUSIONS: The outcome of the present study showed that placement of short Brånemark implants without the use of bone grafting procedures for reconstruction of severely atrophic edentulous mandibles is a highly predictable treatment procedure.

Adult↗

[Balloon catheter endometrial thermotherapy in menorrhagia. New simple and safe alternative to hysterectomy].

Thermal endometrial ablation by means of a silicone balloon catheter is a new form of out-patient treatment for menorrhagia, designed to reduce menstrual blood loss by exerting thermal effects on the endometrium and myometrium without damaging surrounding tissue. Follow-up of 116 of the 117 women who underwent the treatment between August 1993 and December 1996 showed the procedure to be well tolerated, to be without immediate complications, and to be associated with significant reductions in menstrual blood volume and in the reported number of bleeding days (P < 0.001 in both cases). At follow-up after 10-49 months, the success rate was 94 per cent. (This excludes women with uterine cavity changes, or submucosal leiomyomas detected at pretreatment ultrasonography, for whom the treatment is not to be recommended.) In addition to its high success rate, the treatment is safe for the patient and easy for the physician to learn.

Catheter Ablation↗

Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent ventilation: an experimental study.

Airborne contamination with bacteria-carrying particles (cfu/m3) and their sedimentation rate (cfu/m2/h) was compared in an operating room (OR) equipped with two turbulent ventilation systems. One was a thermally based system with inlet of cool clean air at the floor level and evacuation of the air at the ceiling by convection (17 air changes/h). The other was a conventional plenum pressure system with air supply at the ceiling and evacuation at the floor level (16 air changes/h). The study was made during rigidly standardised sham operations (N = 20) performed in the same OR by the same six member team wearing non-woven disposable or cotton clothing. Airborne contamination in the wound and instrument areas was related to the surface contamination rate in the same areas and in addition, on the patient chest and in the periphery of the OR. With the exception of the periphery of the OR, the surface and air contamination rates were highly correlated in both ventilation systems (P = 0.02-0.0006, r2 = 0.52-0.79). This was also true particularly when disposable clothing was used while the correlation was weaker in cotton clothing experiments. An equation describing the relation between surface and air counts is given. Typically, the surface counts were numerically 16-fold the air counts, i.e., the number of colonies sedimenting on four 14 cm-diameter agar plates during 1 h will almost equal the number of airborne cfu per m3. We propose, that sedimentation plates represent not only a technically easier method than air sampling but when correctly used, are also the most realistic indicator of airborne bacterial OR contamination in areas critical for surgery.

Air Microbiology↗

Inconsistent correlation between aerobic bacterial surface and air counts in operating rooms with ultra clean laminar air flows: proposal of a new bacteriological standard for surface contamination.

The relationship between surface contamination (cfus/m2/h) with particles carrying aerobic bacteria and corresponding air contamination rates (cfus/m3) was evaluated in operating rooms (OR) equipped with ultra clean vertical or horizontal laminar airflow (LAF). For the evaluation we collected data during strictly standardized sham operations using non-woven disposable or cotton clothing. Air contamination in the wound and instrument areas (Casella slit sampler) was related to the surface contamination rate (settle plates) in the same areas and in addition, on the patient chest. Typically, the mean surface counts were 20-70 cfus/m2/h and the air counts 1-2 cfus/m3 in disposable clothing experiments, whilst the use of cotton clothing resulted in higher counts of 100-200 cfus/m2/h (wound P > 0.05, patient P > 0.05, instruments P < 0.01) and 4 cfus/m3 (P < 0.02-0.001). In the vertical LAF, taking both disposable and cotton clothing operations together, the surface and air contamination rates (surface/air ratio SAR) were highly correlated (P = 0.02-0.004) and the ratio varied between 18:1 and 50:1 with a mean for wound air of 36:1. Using only disposable clothing in the vertical LAF, the number of significant correlations was reduced. With cotton clothing experiments in vertical LAF and in the horizontal LAF using disposable clothing, no significant correlation between surface and air contamination was found. The wide variation of SAR values and the inconsistent relationship between surface and air counts indicates that measurement of OR air contamination represents an unhelpful method for assessment of surgical site contamination in LAF units. We propose instead that colony counts on sedimentation plates is a clinically more relevant indicator of bacterial OR contamination in LAF units. In addition to the current bacteriological standard for ultra clean OR air of (< 10 cfus/m3) we suggest a corresponding standard for the surface contamination rate of < 350 cfus/m2/h.

Air Microbiology↗

On cutting torque measurements during implant placement: a 3-year clinical prospective study.

BACKGROUND: Evaluation of jaw bone quality at implant placement is mainly based on preoperative radiographic assessments and subjective hand registrations during implant site preparation. An objective technique with cutting torque measurements has been introduced, presenting an objective bone quality or bone hardness value of individual implant sites. PURPOSE: The purpose of this study was to evaluate cutting torque measurements during implant placement and to compare these values in different regions in mandibles and maxillae. The objective was to identify implants at risk for failing at implant placement. MATERIAL AND METHODS: Cutting torque measurements were performed during placement of Mk II self-tapping implants (Brånemark System) in 105 patients, comprising 72 edentulous (40 maxillae) and 34 partially edentulous (22 maxillae) jaws. A total of 523 implants were inserted, of which 420 were of the Mk II design and of which 412 were subjected to cutting torque measurements. Statistical analyses were performed by comparing cutting torque values of maxillae and mandibles and of different jaw regions. Cutting torque values were also correlated with radiographically and clinically assessed bone quality scores. Patients were followed clinically for a minimum of 3 years. RESULTS: A statistically significant difference in cutting torque values of maxillae and mandibles was seen, although not when comparing anterior and posterior regions within the same jaws or of different jaws. Significant correlations were found between values of cutting torque and bone quality. The majority of failures were seen in bone of medium to high density, whereas implants inserted in bone of poor density presented a better outcome, perhaps due to an adapted surgical protocol and an extended healing period. The overall implant survival rate at 3 years was 95%, and when analyzing different jaw categories, survival rates of 92.0% and 99.4% were seen for edentulous maxillae and mandibles, respectively. The corresponding figures for partially edentulous jaws were 95.4% and 97.6%. CONCLUSION: It was not possible to identify sites at risk for future implant losses or to determine a lower limit value of cutting torque in order to achieve successful implant integration.

Adolescent↗

Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study.

Using a one-stage surgical protocol, 75 implants ad modum Brånemark of three different designs were inserted in 15 edentulous mandibles of high bone density. All implants were followed with repeated stability measurements by means of resonance frequency analysis (RFA) from implant placement to connection of the fixed prostheses (3-4 months), in order to evaluate possible stability changes during healing. It was shown that the resonance frequency (RF) values slightly decreased for the majority of the implants during the study period independent of design. Consequently, the results of the present study indicated that the implants were as stable at time of placement as when measured at 3-4 months post-surgery, i.e. when the prostheses were attached. The available data support the concept of direct loading of implants when inserted between the mental interforaminal regions. One implant failed during healing and the corresponding RF measurement disclosed, at six weeks post-surgery, a value being far below the one registered at implant placement. The lowered RF value indicated the failure several weeks before the mobility was clinically diagnosed. The presence or absence of a fixture/abutment junction did not exert any influence on the marginal bone level, as determined radiographically at the end of the short investigation period.

Aged↗

A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study.

Oral implant treatment ad modum Brånemark was undertaken in nine patients with edentulous maxillae. Cutting torque measurements and resonance frequency analyses (RFA) were conducted at implant placement and the corresponding values were subjected to correlation analyses. The implants were also evaluated with RFA at abutment connection and at one-year follow-up in order to identify possible changes in implant stability. A total of 61 implants were inserted, of which 49 were of the Mk II self-tapping type. Two implants were lost during the study period. The cumulative torque was presented as a mean value for the upper/crestal, the middle and the lower/apical third of the implant site respectively, as well as an overall value for the whole site. The highest correlation (r = 0.84, P<0.05) was found when comparing the mean torque values of the upper/crestal portion with the resonance frequency values at implant placement. The Mk II implant sites were divided into three groups based on the values of the cutting torque, i.e. soft (group 1), medium (group 2) and dense bone (group 3). The mean value of each group was plotted against the corresponding mean value of resonance frequency measured at implant insertion. Statistical analysis showed significant differences in resonance frequency at implant insertion between groups 1 and 2 (P = 0.047) and between groups 1 and 3 (P = 0.002). When repeating the resonance frequency analyses at second stage surgery and at one-year follow-up, no significant differences were detected between any of the groups. It was shown that the stability of implants placed in softer bone seemed to "catch up" over time with more dense bone sites.

Aged↗

Induction chemotherapy and radiotherapy in loco-regionally advanced epidermoid carcinoma of the anal canal.

PURPOSE: To evaluate the efficacy of induction chemotherapy in combination with radiotherapy for treatment of loco-regionally advanced epidermoid anal carcinoma. METHODS AND MATERIALS: Thirty-one patients diagnosed during the period 1989-1994 with loco-regionally advanced cancer of the anal canal (phiTmax > or = 4 cm or T4 or N+) were treated with induction chemotherapy consisting of one to three courses of carboplatin (300-375 mg/m2 i.v.) and 5-fluorouracil [5,000 mg/(m2 x 120 h) i.v.] followed by external beam irradiation +/- surgery. RESULTS: The toxicity of the chemotherapy was low. Twenty-nine patients were tumor free after the primary therapy. Kaplan-Meier analyses were made for overall survival, tumor-specific survival, freedom from recurrence, preservation of sphincter, and event-free survival. For these end points the 5-year data were 67, 85, 80, 69, and 51%, respectively. CONCLUSION: The results are promising but a well-designed randomized trial is needed to further elucidate the role of induction chemotherapy in the treatment of loco-regionally advanced anal carcinoma.

Adult↗

Ultraclean laminar airflow ORs.

To minimize postoperative infections, ultraclean laminar airflow (LAF) units equipped with high-efficiency particulate air filters developed for electronic and aerospace technology have been adapted for ORs. Traditionally, the airflow was either vertical or horizontal and, to function properly, encompassed extra side walls inside the OR. Recently, new airstream technology has provided zoned down-flow units that provide an exponential airflow (i.e., resembling an upside-down trumpet mouth). The exponential airflow allows for omission of extra side walls, making them more versatile in clinical use. Each different type of LAF requires knowledge of airstream patterns and how OR team members need to dress and work to prevent contamination of the sterile air and the aseptic areas. This article discusses different LAF systems and related demands on OR clothing and behavior.

Air Microbiology↗

The Swedish National Care Programme for Anal Carcinoma--implementation and overall results.

The Swedish National Care Programme for Anal Carcinoma (SNCPAC) was instituted in order to create a uniform handling policy for anal cancer and thus to accrue a population-based material allowing unbiased analyses. This study evaluates the degree of implementation of the SNCPAC guidelines, and presents overall treatment results in a total of 356 patients with epidermoid cancer of the anus and the perianal region diagnosed in Sweden between 1985 and 1989. Primary treatment according to the guidelines was irradiation up to 40 Gy, Bleomycin was administered intramuscularly before the first 18 fractions. After a 3-week pause, radiotherapy was to be continued up to a dose of 60-64 Gy, if at least an almost complete response was achieved. Otherwise, the patient was recommended surgery within a week. The guidelines were applied in 90%, of cases where such treatment was possible. The 5-year tumour-specific survival rate was 72%. The survival rate was more favourable in perianal tumours (90%) than in anal canal tumours (68%, p < 0.01). The 5-year probability of having a preserved anus was 64% (anal canal/perianal 58%/91%, p < 0.001). Bleomycin did not appear to have any effect on treatment results. The care programme has had a rapid and almost complete nation-wide penetration, and h as created the desired uniformity allowing proper analyses. The treatment results also appear comparable with specialised referral centres.

Adult↗

Thermal conductivity of uterine tissue in vitro.

Thermotherapy of the uterus has emerged as an alternative to hysterectomy in the treatment of menorrhagia, from whence it follows that the thermal properties of uterine tissue have become of importance. This study presents measurements of the thermal conductivity and the water content of uterine tissue in vitro. A steady-state thermal conductivity apparatus, based on the comparison of test samples with a material with known thermal conductivity, is described. Measurements were conducted on tissue samples from eleven patients, directly after hysterectomy. Samples with and without endometrium, as well as coagulated samples, were examined. The thermal conductivity of myometrial tissue was found to be 0.536 +/- 0.012 W m(-1) K(-1) (mean +/- 1 SD) and the corresponding water content was 81.2 +/- 1.5% (mean +/- 1 SD). Measurements on samples with both endometrium and myometrium showed similar thermal conductivity (0.542 +/- 0.008 W m(-1) K(-1), mean +/- 1 SD) and water content (81.6 +/- 0.7%, mean +/- 1 SD). It was also indicated that coagulation causes dehydration, resulting in a lower thermal conductivity.

Body Temperature↗

Endometrial thermal coagulation--degree of uterine fibrosis predicts treatment outcome.

OBJECTIVE: To study the uterine cavity after thermal endometrial destruction for the treatment of menorrhagia by means of a balloon catheter, the Cavaterm system. To relate the appearance of the uterine cavity to the outcome of the treatment. METHODS: Fifty-one of the first 60 women treated with balloon endometrial destruction were examined with hysteroscopy and saline infusion sonography 11-28 months after treatment. RESULTS: Patients with minimal or no bleeding after thermal endometrial destruction had more uterine fibrosis than patients bleeding more. CONCLUSION: The greater the degree of fibrosis of the uterine cavity after balloon endometrial destruction by thermal coagulation, the better the effect on menorrhagia.

Adult↗

Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla.

The aim of this investigation was to evaluate the use of resonance frequency measurements in the clinical measurement of implant stability. Resonance frequency measurements are undertaken by measuring the response of a small transducer attached to an implant fixture or abutment. Two groups of patients were selected for study. Group A comprised 9 patients who had a total of 56 implants placed. Resonance frequency measurements were made at fixture installation and repeated 8 months later at abutment connection. The resonance frequency of the implant/transducer system increased for 50 out of the 56 implants from a mean value of 7473 Hz +/- 127 Hz (P < 0.05) to a mean of 7915 Hz +/- 112 Hz (P < 0.05). Two implants had failed to integrate and the resonance frequency of these had fallen. Group B comprised 9 patients who had been provided with fixed prostheses and had a total of 52 implants placed. They were examined 5 years after fixture placement and the prostheses removed. All implants were judged clinically to be osseointegrated. The level of the marginal bone around each implant was calculated by measuring the number of exposed threads on intraoral periapical radiographs and added to the length of each abutment to give a value termed the effective implant length (EIL). Measurements indicated a correlation (R = -0.78, P < 0.01) between EIL and resonance frequency. The results support the hypothesis that the resonance frequency of an implant/transducer system is related to the height of the implant not surrounded by bone and the stability of the implant/tissue interface as determined by the absence of clinical mobility.

Aged↗