Artefact mimicking tachycardia during magnetic resonance imaging in a patient with an implantable loop recorder.

An implantable loop recorder (ILR) was implanted in a 45 year old man with recurrent syncope. A subsequent episode of injurious syncope led to performance of a cranial and shoulder magnetic resonance imaging (MRI). An artefact mimicking both wide and narrow complex tachycardias was recorded by the ILR during the shoulder MRI but not the cranial MRI. Caution should be used when interpreting the ECGs of ILRs in patients who have undergone MRI.

Artifacts↗

Life-threatening ventricular arrhythmias due to transient or correctable causes: high risk for death in follow-up.

OBJECTIVES: This study evaluated the prognosis of patients resuscitated from ventricular tachycardia (VT) or ventricular fibrillation (VF) with a transient or correctable cause suspected as the cause of the VT/VF. BACKGROUND: Patients resuscitated from VT/VF in whom a transient or correctable cause has been identified are thought to be at low risk for recurrence and often receive no primary treatment for their arrhythmias. METHODS: In the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial, patients with a potentially transient or correctable cause of VT/VF were not eligible for randomization. The mortality of these patients was compared with the mortality of patients with a known high risk of recurrence of VT/VF in the AVID registry. RESULTS: Compared with patients having high risk VT/VF, those with a transient or correctable cause for their presenting VT/VF were younger and had a higher left ventricular ejection fraction. These patients were more often treated with revascularization as the primary therapy, more commonly received a beta-blocker, less often required therapy for congestive heart failure and less commonly received either an antiarrhythmic drug or an implantable cardioverter defibrillator. Nevertheless, subsequent mortality of patients with a transient or correctable cause of VT/VF was no different or perhaps even worse than that of the primary VT/VF population. CONCLUSIONS: Patients identified with a transient or correctable cause for their VT/VF remain at high risk for death. Further research is needed to define truly reversible causes of VT/VF. Meanwhile, these patients may require more aggressive evaluation, treatment and follow-up than is currently practiced.

Chi-Square Distribution↗

Patients at lower risk of arrhythmia recurrence: a subgroup in whom implantable defibrillators may not offer benefit. Antiarrhythmics Versus Implantable Defibrillator (AVID) Trial Investigators.

OBJECTIVES: The goal of this study was to identify subgroups of arrhythmia patients who do not benefit from use of the implantable cardiac defibrillator (ICD). BACKGROUND: Treatment of serious ventricular arrhythmias has evolved toward more common use of the ICD. Since estimates of the cost per year of life saved by ICD therapy vary from $25,000 to perhaps $125,000, it is important to identify patient subgroups that do not benefit from the ICD. METHODS: Data for 491 ICD patients enrolled in the Antiarrhythmics Versus Implantable Defibrillators Study were used to create a hazards model relating baseline factors to time to first recurrent arrhythmia. The model was used to predict the hazard for recurrent arrhythmia among all trial patients. A priori cut points provided lower and higher recurrent arrhythmia risk strata. For each stratum the incremental years of life due to ICD versus antiarrhythmic drug therapy were calculated. RESULTS: Factors that predicted recurrent arrhythmia were: ventricular tachycardia as the index arrhythmia, history of cerebrovascular disease, lower left ventricular ejection fraction, a history of any tachyarrhythmia before the index event and the absence of revascularization after the index event. Survival times (over a follow-up of three years) were identical in each arm of the lowest risk sextile (survival advantage 0.03 +/- 0.12 [se] years), while the survival advantage for patients above the first sextile was 0.27 +/- 0.07 (se) years (two-sided p = 0.05). CONCLUSIONS: Patients presenting with an isolated episode of ventricular fibrillation in the absence of cerebrovascular disease or history of prior arrhythmia who have undergone revascularization or who have moderately preserved left ventricular function (left ventricular ejection fraction > 0.27) are not likely to benefit from ICD therapy compared with amiodarone therapy.

Aged↗

Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection : results and technical considerations.

BACKGROUND: One of the perceived benefits of dual-chamber implantable cardioverter-defibrillators (ICDs) is the reduction in inappropriate therapy due to new detection algorithms. It was the purpose of the present investigation to propose methods to minimize bias during such comparisons and to report the arrhythmia detection clinical results of the PR Logic dual-chamber detection algorithm in the GEM DR ICD in the context of these methods. METHODS AND RESULTS: Between November 1997 and October 1998, 933 patients received the GEM DR ICD in this prospective multicenter study. A total of 4856 sustained arrhythmia episodes (n=311) with stored electrogram and marker channel were classified by the investigators; 3488 episodes (n=232) were ventricular tachycardia (VT)/ventricular fibrillation (VF), and 1368 episodes (n=149) were supraventricular tachycardia (SVT). The overall detection results were corrected for multiple episodes within a patient with the generalized estimating equations (GEE) method with an exchangeable correlation structure between episodes. The relative sensitivity for detection of sustained VT and/or VF was 100.0% (3488 of 3488, n=232; 95% CI 98.3% to 100%), the VT/VF positive predictivity was 88.4% uncorrected (3488 of 3945, n=278) and 78.1% corrected (95% CI 73.3% to 82.3%) with the GEE method, and the SVT positive predictivity was 100.0% (911 of 911, n=101; 95% CI 96% to 100%). CONCLUSIONS: A structured approach to analysis limits the bias inherent in the evaluation of tachycardia discrimination algorithms through the use of relative VT/VF sensitivity, VT/VF positive predictivity, and SVT positive predictivity along with corrections for multiple tachycardia episodes in a single patient.

Algorithms↗

Biventricular pacing for heart failure.

The completed trials of biventricular pacing in congestive cardiac failure are impressively encouraging as a novel therapy for the symptoms of a most devastating disease. The actual delivery of the LV pacing hardware and final patient selection criteria require further refinement, as it is clear that not all patients with heart failure respond favorably. What is clear is that all patients should be prescribed maximally tolerated, proven medical therapy before assessment as to the feasibility of biventricular pacing therapy. This should be the case until potentially proven otherwise in newly planned trials designed to assess the comparative efficacy of both approaches. It is difficult to see that the two approaches should be anything but complementary in their benefit. The expense and potential complication associated with any invasive procedure needs to be considered, however, and it would seem reasonable that all of these patients should be receiving maximally tolerated medical therapy before and after the implantation of a device. Finally, the effect of this therapy on mortality needs to be assessed and, consequently, the requirement for defibrillation capability considered in this population of patients with a known high incidence of sudden death.

Cardiac Pacing, Artificial↗

Correlation of impedance minute ventilation with measured minute ventilation in a rate responsive pacemaker.

Although rate responsive pacing based on impedance minute ventilation (IMV) is now standard, there is almost no data confirming the relationship between IMV from an implanted pacemaker and measured minute ventilation (VE) during exercise. Nineteen completely paced adults implanted with Medtronic Kappa 400 pacemakers underwent symptom-limited maximal metabolic treadmill testing using a modified Minnesota Pacemaker Response Protocol. Minute ventilation (VE, L/min) was simultaneously measured using the flowmeter of a respiratory metabolic gas analysis system and the transthoracic impedance minute ventilation circuitry of the pacemaker. Correlation coefficients (r) were used to find the best fit line to describe the relationship between the two measurements. Mean (+/- SD) r values for the first, second, and third order polynomial equations and for log and exponential equations were: 0.92 +/- 0.08, 0.94 +/- 0.04, 0.95 +/- 0.04, 0.91 +/- 0.06, and 0.91 +/- 0.07, respectively. None of the r values were statistically different from the first order equation. Transthoracic IMV as measured by the Medtronic Kappa 400 is closely correlated to measured minute ventilation and is represented well by a first order (linear) equation.

Adult↗

Assessment of pacemaker chronotropic response: implementation of the Wilkoff mathematical model.

There are few practical guidelines for proper adjustment of rate responsive pacemaker sensor parameters. This study describes the application of the chronotropic assessment exercise protocol (CAEP) and the Wilkoff model of chronotropic response to assess the adjustment of pacemaker sensor parameters. In 31 patients implanted 1 month previously with a dual sensor pacemaker, pacemaker sensor parameters were adjusted to yield a peak sensor rate of 100 beats/min on a simple 6-minute walk (low intensity treadmill exercise [LITE] protocol); the maximum sensor rate was set to the age predicted maximum heart rate (220-age). The rate response behavior of the pacemaker was then assessed using the slope of metabolic-chronotropic relation (MCR) during CAEP exercise. After adjustments based on the LITE protocol, CAEP exercise yielded MCR slopes of 0.92 +/- 0.25 for the entire study group, which compares well with the predicted normal slope of 1. However, 7 of the 31 patients had sensor MCR slopes during CAEP exercise that were 2 SD or more below expected. To test the sensitivity of this approach to suboptimal pacemaker programming or suboptimal exercise, simulations were performed with the maximum sensor rate programmed below age-predicted maximum heart rate or with exercise truncated before maximum exertion; with these conditions, MCR slopes were sharply lower for the entire group. The authors conclude that a simple treadmill walk (LITE) allowed for optimum programming of sensor parameters in most patients, but in a minority the chronotropic behavior was underresponsive. Failure to appropriately adjust pacemaker maximum sensor rate or failure to achieve peak exercise sharply limits the accuracy of this methodology.

Equipment Design↗

Relationship between rehospitalization and future death in patients treated for potentially lethal arrhythmia.

INTRODUCTION: It is generally considered that death is the only appropriate endpoint to evaluate interventions for preventing death; however, this belief may be based on the previous use of inappropriate or inadequate surrogates for death. The aim of this study was to evaluate whether rehospitalization following implementation of an intervention is a reasonable surrogate for death. METHODS AND RESULTS: The time from discharge following intervention to rehospitalization was evaluated for 997 patients discharged after baseline hospitalization in the Antiarrhythmics Versus Implantable Defibrillators Trial. The relationship between rehospitalization for various reasons and subsequent death was compared in the two treatment arms to assess the adequacy of rehospitalization as a surrogate for death. Included were rehospitalization for: any reason, a cardiac problem, a noncardiac problem, new or worsened congestive heart failure (CHF), an acute coronary syndrome, and a cardiac procedure. For all of the reasons except cardiac procedure, rehospitalization was associated with a substantially increased hazard for subsequent death. Rehospitalization for new or worsened CHF was most closely (that is, temporally) related to subsequent death and was the only reason for rehospitalization, which fully explained the treatment effect of implantable cardiac defibrillators compared with antiarrhythmic drugs on death. CONCLUSION: Rehospitalization is a significant risk factor for subsequent death. However, only rehospitalization for new or worsened CHF appears to be a potential surrogate for death in the setting of antiarrhythmic interventions.

Heart Failure↗

Preventing sudden death in coronary cardiomyopathy: implantable defibrillators lead the way.

The Multicenter Unsustained Tachycardia Trial (MUSTT) demonstrated that electrophysiologic testing (EP)-guided therapy significantly reduces arrhythmic death and cardiac arrest in patients with coronary artery disease, a left ventricular ejection fraction of 40% or less, nonsustained ventricular tachycardia, and inducible ventricular arrhythmia on EP testing-but only if the therapy includes an implantable defibrillator. All patients who meet the MUSTT inclusion criteria should undergo an EP test and if positive, should undergo defibrillator implantation.

Arrhythmias, Cardiac↗

Diagnosis and management of infections involving implantable electrophysiologic cardiac devices.

BACKGROUND: Optimal treatment of infections related to implantable electrophysiologic cardiac devices is poorly defined. OBJECTIVE: To describe the clinical presentation, treatment, and outcome of patients with such infections. DESIGN: Retrospective case series. SETTING: The Cleveland Clinic Foundation, Cleveland, Ohio. PATIENTS: 123 patients with infections involving implantable cardiac electrophysiologic devices. MEASUREMENTS: Demographic characteristics, clinical manifestations, time to diagnosis, management, and outcome. RESULTS: 87 patients with permanent pacemakers and 36 patients with implantable cardioverter defibrillators had infections. The most common signs and symptoms were pocket erythema and local pain. The most common pathogens were coagulase-negative staphylococci (68%) and Staphylococcus aureus (23%). In 117 patients (95%), all equipment was extracted and antibiotic therapy lasted a median of 28 days. Operative mortality was zero. Follow-up showed crude mortality and relapse rates of 8% and 3%, respectively. CONCLUSION: For infections related to implantable electrophysiologic devices, complete device removal and antimicrobial therapy allow timely, successful reimplantation at a remote anatomic site without substantial risk for operative mortality or recurrent infection.

Adolescent↗

Cardiac lead extraction with a novel locking stylet.

Extraction of chronically implanted pacing and defibrillator leads is facilitated by using specialized locking stylets placed in the lead to allow application of traction and to stabilize the lead during sheath dissection of fibrotic tissue. We report the initial multicenter series of cases using a novel lead locking device (LLD). In 57 consecutive patients presenting at 6 institutions for lead extraction, 99 leads were treated using the LLD. After removing the pulse generator, leads were severed, the inner coil dilated and an LLD was successfully inserted and locked in the inner lumen of 95/99 (96 %) leads. With traction applied to the LLD, a variety of sheaths were advanced over the lead body to separate it from adhesions. In 97/99 (98 %) leads, all or most of the lead was removed via the implant vein; 2 leads were removed via the femoral vein. No major complications were observed. The LLD deploys safely and reliably, and provides stable support for advancement of dissecting sheaths.

Adult↗

Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty.

The procedure of lead removal has recently matured into a definable, teachable art with its own specific tools and techniques. It is now time to recognize and formalize the practice of lead removal according to the current methods of medicine and the health care industry. In addition, since at this time the only prospective scientific study of lead extraction is the PLEXES trial, we suggest that studies relating to the techniques of and indications for lead extraction be designed. Recommendations for a common set of definitions, for a framework of training and reviewing physicians in the art, for general methods of reimbursement, and for consistency among clinical trials have been made. Implementation of these recommendations will require additional effort and cooperation from practicing physicians, medical societies, hospital administrations, and industry.

Cardiac Surgical Procedures↗

Voltage dependence of ICD lead polarization and the effect of iridium oxide coating.

Nonthoracotomy leads (NTLs) with an iridium oxide (IROX) coating exhibit lower defibrillation thresholds (DFTs) than uncoated NTLs. We tested whether adding an IROX coating to an active pectoral can would influence defibrillation efficacy. However, the primary purpose of this study was to examine the impedance changes that occur at different voltages for uncoated titanium NTLs and identical NTLs with an IROX coating. We studied anesthetized pigs with an NTL placed in the right ventricle and coupled this to an active pectoral can. Biphasic waveform DFTs were obtained for the four NTLs and can combinations: uncoated NTL and uncoated can, uncoated NTL and IROX can, IROX NTL and uncoated can, and IROX NTL and IROX can. The respective energy DFTs were: 23.6 +/- 6.9, 24.1 +/- 6.7, 21.3 +/- 6.0, and 21.4 +/- 7.0 J. The IROX NTL DFTs were significantly lower (P < 0.05) than the uncoated NTL DFTs (either can), confirming our previous study. We then used a low tilt monophasic waveform to assess impedance changes. The impedance rise for each NTL/can combination was measured at 50, 100, 300, and 700 V. Comparisons of impedance changes between voltage levels showed that the impedance rise was inversely related to voltage and was greatest with uncoated NTLs. The IROX coating of the NTL reduced the impedance rise at all shock voltages, but was particularly beneficial at the lower voltages. No advantage was seen when the pectoral can was coated with IROX regardless of which NTL was used. Our results suggest that low voltage applications, such as atrial defibrillation, would benefit most from the IROX-coated NTL, and further studies are warranted in this area.

Animals↗

Influence of posture, breathing pattern, and type of exercise on minute ventilation estimation by a pacemaker transthoracic impedance sensor.

Previous studies have shown a high correlation between transthoracic impedance minute ventilation (IMV) determined by a pacemaker sensor and actual minute ventilation (VE) measured by standard methods. We hypothesized that several factors (e.g., posture, breathing pattern, and exercise type) could potentially affect the calibration between IMV and VE. In patients with Medtronic Kappa 400 pacemakers, VE (L/min) was monitored using a standard cardiopulmonary metabolic gas analysis system with simultaneous recording of IMV (ohms/min) using DR-180 extended telemetry monitors. Effects of posture and of breathing pattern at rest (19 patients; age 60 +/- 13 years) were evaluated by monitoring each patient under three conditions: (a) slow breathing, supine, (b) slow breathing, sitting, and (c) shallow breathing, supine. Calibration at rest was defined as the ratio of IMV to VE. Effect of type of exercise on calibration compared treadmill versus graded bicycle ergometer exercise (18 patients; age 62 +/- 14 years). Calibration during exercise was defined as: (a) "Begin" (the IMV to VE ratio at VE = 10 L/min, the typical VE value at beginning of exercise), and (b) slope of the IMV/VE regression line. Calibration of IMV/VE was significantly smaller for sitting versus supine position (0.7130.177, P < 0.001) and for shallow versus slow breathing (0.7210.373, P < 0.001), and larger for treadmill versus bicycle exercise (Begin: 1.240.43, P = 0.018; Slope: 1.260.42, P = 0.013). In conclusion, posture, breathing pattern, and type of exercise affect the IMV estimation of the actual VE, possibly by altering the static or dynamic geometry (thus, the impedance) of the intrathoracic viscera.

Arrhythmias, Cardiac↗

New approach to biphasic waveforms for internal defibrillation: fully discharging capacitors.

INTRODUCTION: The use of two independent, fully discharging capacitors for each phase of a biphasic defibrillation waveform may lead to the design of a simpler, smaller, internal defibrillator. The goal of this study was to determine the optimal combination of capacitor sizes for such a waveform. METHODS AND RESULTS: Eight full-discharge (95/95% tilt), biphasic waveforms produced by several combinations of phase-1 capacitors (30, 60, and 90 microF) and phase-2 capacitors (1/3, 2/3, and 1.0 times the phase-1 capacitor) were tested and compared to a single-capacitor waveform (120 microF, 65/65% tilt) in a pig ventricular fibrillation model (n = 12, 23+/-2 kg). In the full-discharge waveforms, phase-2 peak voltage was equal to phase-1 peak voltage. Shocks were delivered between a right ventricular lead and a left pectoral can electrode. E50s and V50s were determined using a ten-step Bayesian process. Full-discharge waveforms with phase-2 capacitors of < or =40 microF had the same E50 (6.7+/-1.7 J to 7.3+/-3.9 J) as the single-capacitor truncated waveform (7.3+/-3.7 J), whereas waveforms with phase-2 capacitors of > or =60 microF had an extremely high E50 (14.5+/-10.8 J or greater, P < 0.05). Moreover, of the former set of energy-efficient waveforms, those with phase-1 capacitors of > or =60 microF additionally exhibited V50s that were equivalent to the V50 of the single-capacitor waveform (344+/-65 V to 407+/-50 V vs 339+/-83 V). CONCLUSION: Defibrillation efficacy can be maintained in a full-discharge, two-capacitor waveform with the proper choice of capacitors.

Animals↗

Fully discharging phases. A new approach to biphasic waveforms for external defibrillation.

BACKGROUND: Phase-2 voltage and maximum pulse width are dependent on phase-1 pulse characteristics in a single-capacitor biphasic waveform. The use of 2 separate output capacitors avoids these limitations and may allow waveforms with lower defibrillation thresholds. A previous report also suggested that the optimal tilt may be >70%. This study was designed to determine an optimal biphasic waveform by use of a combination of 2 separate and fully (95% tilt) discharging capacitors. METHODS AND RESULTS: We performed 2 external defibrillation studies in a pig ventricular fibrillation model. In group 1, 9 waveforms from a combination of 3 phase-1 capacitor values (30, 60, and 120 microF) and 3 phase-2 capacitor values (0=monophasic, 1/3, and 1.0 times the phase-1 capacitor) were tested. Biphasic waveforms with phase-2 capacitors of 1/3 times that of phase 1 provided the highest defibrillation efficacy (stored energy and voltage) compared with corresponding monophasic and biphasic waveforms with the same capacitors in both phases except for waveforms with a 30-microF phase-1 capacitor. In group 2, 10 biphasic waveforms from a combination of 2 phase-1 capacitor values (30 and 60 microF) and 5 phase-2 capacitor values (10, 20, 30, 40, and 50 microF) were tested. In this range, phase-2 capacitor size was more critical for the 30-microF phase-1 than for the 60-microF phase-1 capacitor. The optimal combinations of fully discharging capacitors for defibrillation were 60/20 and 60/30 microF. Conclusions-Phase-2 capacitor size plays an important role in reducing defibrillation energy in biphasic waveforms when 2 separate and fully discharging capacitors are used.

Animals↗

Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads.

BACKGROUND: In a previous randomized trial, the 12F laser sheath removed pacing leads via the implant vein more successfully than traditional mechanical tools alone. Two larger sizes of laser sheath, the 14F and 16F models, were developed to extract defibrillator leads and large-diameter pacing leads implanted for the chronic. These devices use pulsed ultraviolet laser light to core though fibrotic tissue grown over the lead body to free the lead from the vasculature. A mandatory prospective registry studied the safety and effectiveness profiles of the larger laser sheaths vis-à-vis the 12F laser sheath. METHODS AND RESULTS: In this study, 863 patients underwent extraction of 1285 leads at 52 sites. Patients treated with the 14F device tended to have older leads than the 12F population; the 16F population, which comprised mostly defibrillator patients, were younger, had younger leads, and were more often male than the 12F population. Clinical success (extracting the entire lead or the lead body minus the distal electrode) was observed in 91% to 92% of cases for all device sizes. The overall complication rate was 3.6%, with 0.8% perioperative mortality. Incidence of complications was independent of laser sheath size. CONCLUSIONS: The 14F and 16F laser sheaths offer an extraction option for larger long-term transvenous pacemaker and defibrillator leads that is as safe and effective as the 12F laser sheath.

Adolescent↗