Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial.

OBJECTIVES: The purpose of this study was to evaluate the safety and effectiveness of pacemaker lead extraction with the excimer sheath in comparison to nonlaser lead extraction. BACKGROUND: Fibrotic attachments that develop between chronically implanted pacemaker leads and to the venous, valvular and cardiac structures are the major obstacles to safe and consistent lead extraction. Locking stylets and telescoping sheaths produce a technically demanding but effective technique of mechanically disrupting the fibrosis. However, ultraviolet excimer laser light dissolves instead of tearing the tissue attachments. METHODS: A randomized trial of lead extraction was conducted in 301 patients with 465 chronically implanted pacemaker leads. The laser group patients had the leads removed with identical tools as the nonlaser group with the exception that the inner telescoping sheath was replaced with the 12-F excimer laser sheath. Success for both groups was defined as complete lead removal with the randomized therapy without complications. RESULTS: Complete lead removal rate was 94% in the laser group and 64% in the nonlaser group (p = 0.001). Failed nonlaser extraction was completed with the laser tools 88% of the time. The mean time to achieve a successful lead extraction was significantly reduced for patients randomized to the laser tools, 10.1 +/- 11.5 min compared with 12.9 +/- 19.2 min for patients randomized to nonlaser techniques (p < 0.04). Potentially life-threatening complications occurred in none of the nonlaser and three of the laser patients, including one death (p = NS). CONCLUSIONS: Laser-assisted pacemaker lead extraction has significant clinical advantages over extraction without laser tools and is associated with significant risks.

Aged↗

Higher energy synchronized external direct current cardioversion for refractory atrial fibrillation.

OBJECTIVES: We sought to evaluate the safety and efficacy of higher energy synchronized cardioversion in patients with atrial fibrillation refractory to standard energy direct current (DC) cardioversion. BACKGROUND: Standard external electrical cardioversion fails to restore sinus rhythm in 5% to 30% of patients with atrial fibrillation. METHODS: Patients with atrial fibrillation who failed to achieve sinus rhythm after at least two attempts at standard external cardioversion with 360 J were included in the study. Two external defibrillators, each connected to its own pair of R-2 patches in the anteroposterior position, were used to deliver a synchronized total of 720 J. RESULTS: Fifty-five patients underwent cardioversion with 720 J. Mean weight was 117 +/- 23 kg (body mass index 48.3 +/- 4.1 kg/m2). Structural heart disease was present in 76% of patients. Mean left ventricular ejection fraction was 45 +/- 12%. Atrial fibrillation was present for over three months in 55% of the patients. Sinus rhythm was achieved in 46 (84%) of the 55 patients. No major complications were observed. No patient developed hemodynamic compromise and no documented cerebrovascular accident occurred within one month after cardioversion. Of the 46 successful cardioversions, 18 patients (39%) remained in sinus rhythm over a mean follow-up of 2.1 months. CONCLUSIONS: External higher energy cardioversion is effective in restoring sinus rhythm in patients with atrial fibrillation refractory to standard energy DC cardioversion. This method is safe and does not result in clinical evidence of myocardial impairment. It may be a useful alternative to internal cardioversion because it could be done within the same setting of the failed standard cardioversion and obviates the need to withhold protective anticoagulation for internal cardioversion.

Adult↗

External exponential biphasic versus monophasic shock waveform: efficacy in ventricular fibrillation of longer duration.

Ventricular fibrillation (VF) duration may be a factor in determining the defibrillation energy for successful defibrillation. Exponential biphasic waveforms have been shown to defibrillate with less energy than do monophasic waveforms when used for external defibrillation. However, it is unknown whether this advantage persists with longer VF duration. We tested the hypothesis that exponential biphasic waveforms have lower defibrillation energy as compared to exponential monophasic waveforms even with longer VF duration up to 1 minute. In a swine model of external defibrillation (n = 12, 35 +/- 6 kg), we determined the stored energy at 50% defibrillation success (E50) after both 10 seconds and 1 minute of VF duration. A single exponential monophasic (M) and two exponential biphasic (B1 and B2) waveforms were tested with the following characteristics: M (60 microF, 70% tilt), B1 (60/60 microF, 70% tilt/3 ms pulse width), and B2 (60/20 microF, 70% tilt/3 ms pulse width) where the ratio of the phase 2 leading edge voltage to that of phase 1 was 0.5 for B1 and 1.0 for B2. E50 was measured by a Bayesian technique with a total often defibrillation shocks in each waveform and VF duration randomly. The E50 (J) for M, B1, and B2 were 131 +/- 41, 57 +/- 18,* and 60 +/- 26* with 10 seconds of VF duration, respectively, and 114 +/- 62, 77 +/- 45,* and 72 +/- 53* with 1 minute of VF duration, respectively (*P < 0.05 vs M). There was no significant difference in the E50 between 10 seconds and 1 minute of VF durations for each waveform. We conclude that (1) the E50 does not significantly increase with lengthening VF durations up to 1 minute regardless of the shock waveform, and (2) external exponential biphasic shocks are more effective than monophasic waveforms even with longer VF durations.

Analysis of Variance↗

Effects of extracorporeal shock wave lithotripsy on tiered therapy implantable cardioverter defibrillators.

The effects of extracorporeal shock wave lithotripsy (ESWL) were tested on four advanced generation implantable cardioverter-defibrillators (ICDs) in vitro and in vivo in two patients. During in vitro testing, advancement of nonsustained episode counters occurred in one device, and a set screw and power source cell loosened in another, which was connected to an external power source. No arrhythmias occurred during in vivo procedures, but programmed parameters were reset and elective replacement indicated after one procedure. ESWL can be performed safely in selected patients with ICDs, but testing should be performed afterwards to confirm satisfactory function and component continuity.

Defibrillators, Implantable↗

Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996. U.S. Extraction Database, MED Institute.

Of the 400,000-500,000 permanent pacemaker leads implanted worldwide each year, around 10% may eventually fail or become infected, becoming potential candidates for removal. Intravascular techniques for removing problematic or infected leads evolved over a 5-year period (1989-1993). This article analyzes results from January 1994 through April 1996, a period during which techniques were fairly stable. Extraction of 3,540 leads from 2,338 patients was attempted at 226 centers. Indications were: infection (27%), nonfunctional or incompatible leads (25%), Accufix or Encore leads (46%), or other causes (2%). Patients were 64+/-17 years of age (range 5-96); 59% were men, 41% women. Leads were implanted 47+/-41 months (maximum 26 years), in the atrium (53%), ventricle (46%), or SVC (1%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, and/or transfemorally using snares, retrieval baskets, and sheaths. Complete removal was achieved for 93% of leads, partial for 5%, and 2% were not removed. Risk of incomplete or failed extraction increased with implant duration (P<0.0001), less experienced physicians (P<0.0001), ventricular leads (P<0.005), noninfected patients (P<0.0005), and younger patients (P<0.0001). Major complications were reported for 1.4% of patients (<1% at centers with >300 cases), minor for 1.7%. Risk of complications increased with number of leads removed (P<0.005) and with less experienced physicians (P<0.005); risk of major complications was higher for women (P<0.01). Given physician experience, appropriate precautions, and appropriate patient selection, contemporary lead removal techniques allow success with low complication rates.

Adolescent↗

Biventricular shocking leads improve defibrillation efficacy.

INTRODUCTION: A single lead active can configuration has been widely used in patients with life-threatening ventricular arrhythmias. Occasionally, however, such a defibrillation lead configuration may not achieve adequate defibrillation threshold (DFT). The purpose of this study was to determine whether addition of a left ventricular (LV) lead can improve defibrillation efficacy. METHODS AND RESULTS: Three transvenous defibrillation leads (8.3-French with a 5-cm long unipolar coil) were placed in the right ventricle (RV), LV, and superior vena cava (SVC), along with an active can (92 cm2) in the left subpectoral area. The DFT stored energy of seven combinations of these defibrillation leads were compared in a pig ventricular fibrillation model using a biphasic defibrillation waveform (125 microF, 6.5/3.5 msec). A biventricular leads active can configuration in which the RV and LV leads were of the same polarity reduced the DFT stored energy by approximately 35% when compared to a single RV lead active can configuration (9.6 +/- 3.0 J vs 15.0 +/- 7.2 J, respectively, P = 0.02). Moreover, adding a SVC lead further reduced the DFT energy (8.4 +/- 3.3 J). CONCLUSION: A biventricular leads active can configuration can significantly improve defibrillation efficacy as compared to a single lead active can configuration. In such a defibrillation lead configuration, the polarity of RV and LV leads should be the same.

Animals↗

Optimal small-capacitor biphasic waveform for external defibrillation: influence of phase-1 tilt and phase-2 voltage.

BACKGROUND: Biphasic waveforms have been reported to be more efficacious than monophasic waveforms for external defibrillation. This study examined the optimal phase-1 tilts and phase-2 leading-edge voltages with small capacitors (60 and 20 microF) for external defibrillation. We also assessed the ability of the "charge-burping" model to predict the optimal waveforms. METHODS AND RESULTS: Two groups of studies were performed. In group 1, 9 biphasic waveforms from a combination of 3 phase-1 tilt values (30%, 50%, and 70%) and 3 phase-2 leading-edge voltage values (0.5, 1.0, and 1.5 times the phase-1 leading-edge voltage, V1) were tested. Phase-2 pulse width was held constant at 3 ms in all waveforms. Two separate 60- microF capacitors were used in each phase. The energy value that would produce a 50% likelihood of successful defibrillation (E50) decreased with increasing phase-1 tilt and increased with increasing phase-2 leading-edge voltage except for the 30% phase-1 tilt waveforms. In group 2, 9 waveforms were identical to the waveforms in group 1, except for a 20- microF capacitor for phase 2. E50 decreased with increasing phase-1 tilt. Phase-2 leading-edge voltage of 1.0 to 1.5 V1 appeared to minimize E50 for phase-1 tilt of 50% and 70% but worsened E50 for phase-1 tilt of 30%. There was a significant correlation between E50 and residual membrane voltage at the end of phase 2, as calculated by the charge-burping model in both groups (group 1, R2=0.47, P<0.001; group 2, R2=0.42, P<0.001). CONCLUSIONS: The waveforms with 70% phase-1 tilt were more efficacious than those with 30% and 50%. The relationship of phase-2 leading-edge voltage to defibrillation efficacy depended on phase-2 capacitance. The charge-burping model predicted the optimal external biphasic waveform.

Animals↗

Is hospital admission for initiation of antiarrhythmic therapy with sotalol for atrial arrhythmias required? Yield of in-hospital monitoring and prediction of risk for significant arrhythmia complications.

OBJECTIVES: We sought to determine the yield of in-hospital monitoring for detection of significant arrhythmia complications in patients starting sotalol therapy for atrial arrhythmias and to identify factors that might predict safe outpatient initiation. BACKGROUND: The need for hospital admission during initiation of antiarrhythmic therapy has been questioned, particularly for sotalol, with which proarrhythmia may be dose related. METHODS: The records of 120 patients admitted to the hospital for initiation of sotalol therapy were retrospectively reviewed to determine the incidence of significant arrhythmia complications, defined as new or increased ventricular arrhythmias, significant bradycardia or excessive corrected QT (QTc) interval prolongation. RESULTS: Twenty-five patients (20.8%) experienced 35 complications, triggering therapy changes during the hospital period in 21 (17.5%). New or increased ventricular arrhythmias developed in 7 patients (5.8%) (torsade de pointes in 2), significant bradycardia in 20 (16.7%) (rate <40 beats/min in 13, pause >3.0 s in 4, third-degree atrioventricular block in 1, permanent pacemaker implantation in 3) and excessively prolonged QTc intervals in 8 (6.7%) (dosage reduced or discontinued in 6). Time to the earliest detection of complications was 2.1 +/- 2.5 (mean +/- SD) days after initiation of sotalol, with 22 of 25 patients meeting criteria for complications within 3 days of monitoring. Baseline electrocardiographic intervals or absence of heart disease failed to distinguish a low risk group. Multivariate analysis identified absence of a pacemaker as the only significant predictor of arrhythmia complications (p = 0.022). CONCLUSIONS: Because clinically significant complications can be detected with in-hospital monitoring in one of five patients starting sotalol therapy, hospital admission is warranted for initiation of sotalol. Patients without pacemakers are at higher risk for these complications.

Aged↗

NASPE expert consensus document: use of i.v. (conscious) sedation/analgesia by nonanesthesia personnel in patients undergoing arrhythmia specific diagnostic, therapeutic, and surgical procedures.

Use of IV (Conscious) Sedation/Analgesia by Nonanesthesia Personnel in Patients Undergoing Arrhythmia Specific Diagnostic, Therapeutic, and Surgical Procedures. This article is intended to inform practitioners, payers, and other interested parties of the opinion of the North American Society of Pacing and Electrophysiology (NASPE) concerning evolving areas of clinical practice or technologies or both, that are widely available or are new to the practice community. Expert consensus documents are so designated because the evidence base and experience with the technology or clinical practice are not yet sufficiently well developed, or rigorously controlled trials are not yet available that would support a more definitive statement. This article has been endorsed by the American College of Cardiology, October 1997.

Anesthesiology↗

Effects of respiration phase on ventricular defibrillation threshold in a hot can electrode system.

The impedance of defibrillation pathways is an important determinant of ventricular defibrillation efficacy. The hypothesis in this study was that the respiration phase (end-inspiration versus end-expiration) may alter impedance and/or defibrillation efficacy in a "hot can" electrode system. Defibrillation threshold (DFT) parameters were evaluated at end-expiration and at end-inspiration phases in random order by a biphasic waveform in ten anesthetized pigs (body weight: 19.1 +/- 2.4 kg; heart weight: 97 +/- 10 g). Pigs were intubated with a cuffed endotracheal tube and ventilated through a Drager SAV respirator with tidal volume of 400-500 mL. A transvenous defibrillation lead (6 cm long, 6.5 Fr) was inserted into the right ventricular apex. A titanium can electrode (92-cm2 surface area) was placed in the left pectoral area. The right ventricular lead was the anode for the first phase and the cathode for the second phase. The DFT was determined by a "down-up down-up" protocol. Statistical analysis was performed with a Wilcoxon matched pair test. The median impedance at DFT for expiration and inspiration phases were 37.8 +/- 3.1 omega, and 39.3 +/- 3.6 omega, respectively (P = 0.02). The stored energy at DFT for expiration and inspiration phases were 5.7 +/- 1.9 J and 6.0 +/- 1.0 J, respectively (P = 0.594). Shocks delivered at end-inspiration exhibited a statistically significant increase in electrode impedance in a " hot can" electrode system. The finding that DFT energy was not significantly different at both respiration phases indicates that respiration phase does not significantly affect defibrillation energy requirements.

Animals↗

What internists should know about amiodarone.

Amiodarone is a potent and versatile antiarrhythmic. Despite side effects involving the lungs, heart, thyroid, and other organs, it is effective in the treatment of refractory atrial and ventricular arrhythmias and it has unique safety in patients with coronary disease and left ventricular dysfunction. This review discusses the evolving indications for amiodarone and management of toxicities and drug interactions.

Amiodarone↗

Additional lead improves defibrillation efficacy with an abdominal 'hot can' electrode system.

BACKGROUND: Although the left prepectoral site is preferred for "hot can" placement, this site is unavailable in some patients. We evaluated the influence of electrode location on defibrillation thresholds with alternative hot can and transvenous lead configurations. METHODS AND RESULTS: Three interrelated studies were performed. In group 1, the importance of hot can location was investigated by pairing a right ventricular lead to five different hot can placement sites in seven pigs. The defibrillation energies for right pectoral, left pectoral, left subaxillary, and right and left abdominal hot can sites were 20.3+/-2.7,* 15.9+/-3.8, 14.9+/-2.5, 32.0+/-3.4,* and 30.0+/-3.4 J,* respectively (*P<.005 versus left pectoral and left subaxillary sites). In group 2, the value of a three-electrode configuration with an abdominal hot can placement was investigated by adding a subclavian vein lead to the pectoral or abdominal hot can configurations in seven pigs. The defibrillation energies for left pectoral and abdominal sites were 18.6+/-4.2 and 29.0+/-5.8 J (P=.0001), respectively. The addition of a right or left subclavian vein lead with an abdominal hot can reduced the threshold to 19.3+/-4.2* or 18.8+/-3.2,* respectively (*P=.0001 versus abdominal site). In group 3, the contribution of the abdominal hot can electrode to the three-electrode configuration was tested by a comparison with two purely transvenous two-electrode configurations in six pigs. The defibrillation energy (19.9+/-3.2 J) for the abdominal hot can with a subclavian vein lead was lower than the transvenous lead configurations with a subclavian vein (29.0+/-2.5 J, P=.0001) or a superior vena cava lead (30.7+/-3.7 J, P=.0001). The right ventricular lead was the sole cathode during the first phase of the biphasic shock in all experiments. CONCLUSIONS: Defibrillation energy depends on the hot can placement site. The addition of a subclavian vein lead with an abdominal hot can improves defibrillation efficacy to the level of the pectoral placement and is better than a purely transvenous lead configuration.

Abdomen↗

Effects of polarity on defibrillation thresholds using a biphasic waveform in a hot can electrode system.

The polarity of a monophasic and biphasic shocks have been reported to influence DFTs in some studies. The purpose of this study was to evaluate the effect of the first phase polarity on the DFT of a biphasic shock utilizing a nonthoracotomy "hot can" electrode configuration which had a 90-microF capacitance. We tested the hypothesis that anodal first phase was more effective than cathodal ones for defibrillation using biphasic shocks in ten anesthetized pigs weighing 38.9 +/- 3.9 kg. The lead system consisted of a right ventricular catheter electrode with a surface area of 2.7 cm2 and a left pectoral "hot can" electrode with 92.9 cm2 surface area. DFT was determined using a repeated "down-up" technique. A shock was tested 10 seconds after initiation of ventricular fibrillation. The mean delivered energy at DFT was 11.2 +/- 1.7 J when using the right ventricular apex electrode as the cathode and 11.3 +/- 1.2 J (P = NS) when using it as the anode. The peak voltage at DFT was also not significantly different (529.0 +/- 41.3 and 531.8 +/- 28.6 V, respectively). We concluded that the first phase polarity of a biphasic shock used with a nonthroracotomy "hot can" electrode configuration did not affect DFT.

Animals↗

Automated ventricular tachyarrhythmia recognition: a combination of cycle length and nonlinear dynamics measurements.

INTRODUCTION: Cardiac monitoring devices such as external cardioverter defibrillators and ICU computerized ECG monitoring systems sense individual QRS complexes to detect and subclassify ventricular tachyarrhythmias. Many algorithms that evaluate ECG morphology mark individual QRS complexes so that specific waveform characteristics can be measured. QRS sensors miss a percentage of electrogram events, especially during fibrillatory rhythms; thus, a morphology algorithm that helps subclassify arrhythmias without marking individual electrogram events may be more robust and improve arrhythmia detection accuracy. METHODS AND RESULTS: Four nonlinear dynamics calculations were evaluated for detecting ventricular tachyarrhythmias and for subclassifying monomorphic ventricular tachycardia (MVT) and polymorphic ventricular tachycardia (PVT). Five-second epochs of normal (NML, n = 48), MVT (n = 58), and PVT (n = 75) rhythms were presented to a statistical discriminant function based on cycle length (CL), and its performance was compared to two other discriminant functions, one consisting of the nonlinear dynamics calculations and one consisting of a combination of all variables. The discriminant function based on nonlinear dynamics calculations and CL detected 100% of the ventricular tachyarrhythmias, and subclassified more (P < 0.001) MVT and PVT arrhythmias (90%) than that based on CL alone (71%). CONCLUSIONS: The nonlinear dynamics measurements used in this study significantly increased the subclassification accuracy of the CL-based discriminant function, and they were calculated from ECG signals without marking individual QRS complexes. Therefore, arrhythmia detectors that use nonlinear dynamics measurements may commit fewer classification errors due to QRS undersensing and aid therapy decisions when circumstances suggest that QRS sensing is inaccurate.

Electrocardiography↗

Sawtooth first phase biphasic defibrillation waveform: a comparison with standard waveform in clinical devices.

INTRODUCTION: A major limitation in a conventional truncated exponential waveform is the rapid drop in current that results in short duration of high current or longer duration with a lower average current. We hypothesized that increasing the first phase average current by boosting the decaying waveform prior to phase reversal may improve defibrillation efficacy. METHODS AND RESULTS: To better simulate a "rectangular" waveform during the first phase, a "sawtooth" defibrillation waveform was constructed using "parallel-series" switching of capacitances (each 30 microF) during the first phase. This permitted a boost in the voltage late in the first phase. This sawtooth biphasic waveform (sawtooth) was compared to two clinical waveforms: a 135-microF capacitance (control-1) and a 90-microF capacitance (control-2) waveform. Defibrillation threshold (DFT) parameters were evaluated in 13 anesthetized pig models using a system consisting of a transvenous right ventricular apex lead (anode) and a left pectoral "hot can" electrode (cathode) system. DFT was determined by a "down-up down-up" protocol. The stored energy for sawtooth, control-1, and control-2 was 10.5 +/- 2.8 J, 12.3 +/- 3.7 J*, and 12.2 +/- 2.8 J*, respectively (*P < or = 0.01 vs sawtooth). The average current of the first phase for sawtooth, control-1, and control-2 was 7.6 +/- 1.3 A, 4.7 +/- 0.9 A*, and 6.2 +/- 0.9 A*, respectively (*P = 0.0001 vs sawtooth). CONCLUSION: A sawtooth biphasic waveform utilizing a "parallel-series" switching system of smaller capacitors can improve defibrillation efficacy. A higher average current in the first phase generated by such a waveform may contribute to more efficient defibrillation by facilitating myocyte capture.

Animals↗

Optimized first phase tilt in "parallel-series" biphasic waveform.

INTRODUCTION: A biphasic defibrillation waveform can achieve a large second phase leading-edge voltage by a "parallel-series" switching system. Recently, such a system using two 30-microF capacitances demonstrated better defibrillation threshold than standard waveforms available in current implantable devices. However, the optimized tilt of such a "parallel-series" system had not been defined. METHODS AND RESULTS: Defibrillation thresholds were evaluated for five different biphasic "parallel-series" waveforms (60/15 microF) and a biphasic "parallel-parallel" waveform (60/60 microF) in 12 anesthetized pigs. The five "parallel-series" waveforms had first phase tilts of 40%, 50%, 60%, 70%, and 80% with second phase pulse width of 3 msec. The "parallel-parallel" waveform had first phase tilt of 50% with second phase pulse width of 3 msec. The defibrillation lead system comprised a left pectoral "hot can" electrode (cathode) and a right ventricular lead (anode). The stored energy at defibrillation threshold of the "parallel-series" waveform with first phase tilts of 40%, 50%, 60%, 70%, and 80% was 7.0 +/- 2.1, 6.1 +/- 2.8, 6.8 +/- 2.8, 7.2 +/- 2.9, and 8.4 +/- 3.1 J, respectively. The stored energy of the "parallel-series" waveform with a 50% first phase tilt was 16% less than the nonswitching "parallel-parallel" waveform (7.3 +/- 2.8 J, P = 0.006). CONCLUSIONS: A first phase tilt of 50% maximized defibrillation efficacy of biphasic waveforms implemented with a "parallel-series" switching system. This optimized "parallel-series" waveform was more efficient than the comparable "parallel-parallel" biphasic waveform having the same first phase capacitance and tilt.

Animals↗

Exercise testing and training in patients with malignant arrhythmias.

Patients with malignant arrhythmias are a challenge when they present to the laboratory for exercise testing and training. The complex metabolic and electrophysiological changes that occur during and after exercise may suppress or potentiate arrhythmias and alter the efficacy and safety of antiarrhythmic agents. The presence of an ICD adds a level of complexity to the study; however, a general understanding of how ICDs function and a review of the programmed parameters before the study will result in a lesser likelihood of complication and more efficient and appropriate action, should a complication occur. Exercise testing and training are valuable methods for the evaluation and treatment of patients with malignant ventricular arrhythmias. Exercise testing is a useful adjunctive technique in the exposure of arrhythmia and the evaluation of the efficacy and proarrhythmic potential of antiarrhythmic agents. These patients are excellent candidates for rehabilitation and exercise training programs, which may result in increased functional capacity and improved quality of life. With this knowledge and adherence to the appropriate guidelines for patient selection and testing, exercise testing and training of patients with malignant arrhythmias can be prescribed and conducted in a safe, controlled manner in an atmosphere of confidence and professionalism.

Arrhythmias, Cardiac↗

Large change in voltage at phase reversal improves biphasic defibrillation thresholds. Parallel-series mode switching.

BACKGROUND: Multiple factors contribute to an improved defibrillation threshold of biphasic shocks. The leading-edge voltage of the second phase may be an important factor in reducing the defibrillation threshold. METHODS AND RESULTS: We tested two experimental biphasic waveforms with large voltage changes at phase reversal. The phase 2 leading-edge voltage was twice the phase 1 trailing-edge voltage. This large voltage change was achieved by switching two capacitors from parallel to series mode at phase reversal. Two capacitors were tested (60/15 microfarads [microF] and 90/22.5 microF) and compared with two control biphasic waveforms for which the phase 1 trailing-edge voltage equaled the phase 2 leading-edge voltage. The control waveforms were incorporated into clinical (135/135 microF) or investigational devices (90/90 microF). Defibrillation threshold parameters were evaluated in eight anesthetized pigs by use of a nonthoracotomy transvenous lead to a can electrode system. The stored energy at the defibrillation threshold (ion joules) was 8.2 +/- 1.5 for 60/15 microF (P < .01 versus 135/135 microF and 90/90 microF), 8.8 +/- 2.4 for 90/22.5 microF (P < .01 versus 135/135 microF and 90/90 microF), 12.5 +/- 3.4 for 135/135 microF, and 12.6 +/- 2.6 for 90/90 microF. CONCLUSIONS: The biphasic waveform with large voltage changes at phase reversal caused by parallel-series mode switching appeared to improve the ventricular defibrillation threshold in a pig model compared with a currently available biphasic waveform. The 60/15-microF capacitor performed as well as the 90/ 22.5-microF capacitor in the experimental waveform. Thus, smaller capacitors may allow reduction in device size without sacrificing defibrillation threshold energy requirements.

Animals↗