PubMed HealthSearch

Biomedical subjects

B McArdle

Publications and source records attributed to B McArdle.

At least 19 recordsLinked to original sources

AtUBP3 and AtUBP4 are two closely related Arabidopsis thaliana ubiquitin-specific proteases present in the nucleus.

The ubiquitin-specific proteases (UBPs) are a class of enzymes vital to the ubiquitin pathway. These enzymes cleave ubiquitin at its C-terminus from two types of substrates containing (i) ubiquitin in an alpha-amino linkage, as found in the primary ubiquitin translation products, polyubiquitin and ubiquitin-ribosomal fusion proteins, or (ii) ubiquitin in an epsilon-amino linkage, as found in multiubiquitin chains either unattached or conjugated to cellular proteins. We have isolated cDNAs for two Arabidopsis thaliana genes, AtUBP3 and AtUBP4, which encode UBPs that are 93% identical. These two cDNAs represent the only two members of this subgroup and encode the smallest UBPs described to date in any organism. Using in vivo assays in Escherichia coli that allow the coexpression of a UBP with a putative substrate, we have shown that AtUBP3 and AtUBP4 can specifically deubiquitinate the artificial substrate Ub-X-beta-gal but cannot act upon the natural alpha-amino-linked ubiquitin fusions Arabidopsis Ub-CEP52 and Arabidopsis polyubiquitin. Affinity-purified antibody prepared against AtUBP3 expressed in E. coli recognizes both AtUBP3 and AtUBP4. AtUBP3 and/or AtUBP4 are present in all Arabidopsis organs examined and at multiple developmental stages. Subcellular localization studies show that AtUBP3 and/or AtUBP4 are present in nuclear extracts. Possible physiological roles for these UBPs are discussed.

Amino Acid Sequence

Comparison of plasma and serum for antibody detection using DiaMed microtubes.

Atypical antibody detection in DiaMed microtubes using a low-ionic-strength saline (LISS) indirect antiglobulin technique (IAT) was assessed using both serum and plasma. During the first period of the study all atypical antibodies originally detected in serum were also detected in EDTA plasma with comparable reaction strengths. Two of 73 antibodies were not detected in citrated plasma. During the second period of the study all routine antibody screens were performed in both serum and EDTA plasma. More clinically significant antibodies were detected in EDTA plasma than in serum. More false positives and non-specific antibodies were also detected in EDTA plasma. It is concluded that EDTA plasma is a suitable medium for antibody detection using LISS IAT in DiaMed gel microtubes.

Blood

A comparison of five commercial thromboplastins: ISI re-evaluation on an automated coagulometer.

Five commercial rabbit brain thromboplastins were compared with an International Reference Preparation on an ACL coagulometer, using 90 patients stabilized on warfarin and 22 normal individuals. The prothrombin times were converted to INRs using the thromboplastin manufacturers' quoted ISI. The quoted ISIs were reassigned using orthogonal regression analysis and then used to recalculate INRs for patient and commercial INR control plasmas. This showed that the manufacturers' quoted ISIs and the INR control plasma results were inconsistent. With one thromboplastin the manufacturers quoted ISI changed from 1.17 to 1.05 whilst the control plasma results changed from an INR of 4.3 to an INR of 3.7 (manufacturer's INR, 3.3). In most routine laboratories ISI reassignment is not practical. We conclude that the availability of a reliable plasma calibrant is essential for the accurate calculation of INRs at a local level.

Animals

Automated blood grouping by gel technology.

The ID-Sampler II, an automated liquid handling system, is designed specifically for use with current gel technology. It was found to be reliable, easy to use and fully alarmed, making it a 'walk-away' instrument. Over a three-month period samples for ABO/Rh(D) grouping, antibody screening and compatibility testing were tested in parallel with our routine microtitre plate and gel techniques. No ABO/Rh(D) errors occurred on the automated system and antibody screening results were comparable to our routine methods.

ABO Blood-Group System

The effect of increasing fibrinolysis in patients with rheumatoid arthritis: a double blind study of stanozolol.

Fibrin deposition in rheumatoid arthritis may be responsible for some of the clinical manifestations of the disease. It has been shown that in severe rheumatoid arthritis fibrinolysis is decreased but can be stimulated using the fibrinolytic enhancing agent stanozolol. A prolonged increase in fibrinolysis may decrease joint fibrin deposition and lead to clinical improvement and we have therefore investigated stanozolol as a therapeutic agent. Forty patients were enrolled. Twenty patients received stanozolol 5 mg twice daily for six months and 20 received a matching placebo. Assessment of disease activity was made in the conventional way. Results show that the two groups were comparable. After six months nine of the control patients had withdrawn because of drug ineffectiveness compared with two stanozolol patients, and five control patients felt they had improved compared with 15 stanozolol patients. Disease activity had significantly decreased by the end of the study in the treated group, and detailed analysis showed improvement in ESR, articular index, duration of morning stiffness and visual analogue pain scale. We suggest that stanozolol may be of value in rheumatoid arthritis although this pilot study has looked at only small numbers of patients over a short period.

Arthritis, Rheumatoid

Falsely prolonged prothrombin time due to an inhibitor to human thromboplastin.

A patient with nephrotic syndrome of unknown aetiology was found to have a grossly prolonged prothrombin time in the absence of any other coagulation abnormality and with no clinical bleeding problem. Subsequent investigations showed his plasma contained an inhibitor-like substance, directed against human but not animal thromboplastin.

Humans

Decreased plasma fibrinolysis in patients with rheumatoid arthritis.

We have investigated the fibrinolytic status of 56 patients with rheumatoid arthritis (RA). Plasma fibrinogen and plasminogen were significantly elevated. Levels of these two substrates, along with alpha 2 macroglobulin and antithrombin III correlated with disease activity. Plasminogen activator (PA) activity was decreased in patients with severe disease. Twelve patients were given stanozolol, a fibrinolytic enhancing agent, for two months as a test for endothelial production of plasminogen activator. This caused a significant increase in blood plasminogen and PA activity. Five patients received a two-week course of stanozolol with joint aspiration before and after. Joint plasminogen levels were increased. We suggest that inadequate fibrinolysis occurs in RA, and that this may contribute to some of the pathological features of the disease. It is possible to stimulate both blood and joint fibrinolysis by stanozolol. A more prolonged increase in plasminogen activator activity might decrease joint fibrin deposition, and stanozolol should be investigated as a therapeutic agent in RA.

Antithrombin III

Epoprostenol (prostacyclin) and severe arterial disease. A double-blind trial.

A 96 h infusion of epoprostenol (prostacyclin) or placebo was given as a treatment for rest pain to 28 patients with severe peripheral arterial disease. 24 h after the end of the infusion patients given epoprostenol had significantly less pain and took fewer analgesics tablets than did the controls. In some patients the epoprostenol effect lasted for over 1 month.

Arterial Occlusive Diseases

Barium-induced skeletal muscle paralysis in the rat, and its relationship to human familial periodic paralysis.

An in vivo study of skeletal muscle paralysis induced by intravenous barium chloride has been made in curarized and non-curarized rats. The influence of potassium and calcium chlorides, propranolol, ouabain, and prior adrenalectomy on the paralysis has also been studied. Paralysis is found to be due to a direct effect on skeletal muscle, and to correlate well with the development of hypokalaemia. Possible mechanisms of action of barium are discussed, and attention is drawn to the similarity between barium poisoning and hypokalaemic familial periodic paralysis.

Adrenal Glands