PubMed HealthSearch

Biomedical subjects

B Murphy

Publications and source records attributed to B Murphy.

At least 91 records · Page 5Linked to original sources

Molecular cloning and characterization of the novel, human complement-associated protein, SP-40,40: a link between the complement and reproductive systems.

The cDNA sequence encoding the human complement-associated protein, SP-40,40, is reported. The two chains of SP-40,40 are coded in a single open reading frame on the same mRNA molecule, indicating the existence of a biosynthetic precursor protein which matures post-synthetically by the proteolysis of at least one peptide bond. The precursor is preceded by a signal sequence for vectorial export and contains six N-linked glycosylation sites distributed equally between the two chains of the structure. The sequence of the SP-40,40 precursor bears a 77% identity to a rat sulphated glycoprotein-2 (SGP-2) which is the major secreted product of Sertoli cells. The presence of SP-40,40 within human seminal plasma at levels comparable to those in serum was demonstrated, indicating that SP-40,40 and SGP-2 are serum and seminal forms of the same protein. A sequence of 23 amino acids within the beta-chain of SP-40,40 exhibited significant homology to corresponding segments located within complement components C7, C8 and C9. The short cysteine-containing motif represented the only evidence of a possible vestigial relationship between SP-40,40 and other complement components. The precise role of SP-40,40 is not known in either blood or semen but the present findings document an intriguing link between the immune and the reproductive systems.

Amino Acid Sequence

Nucleotide sequence of the avian influenza A/Mallard/NY/6750/78 virus polymerase genes.

The avian influenza A/Mallard/NY/6750/78 virus is currently being evaluated as a donor of attenuating genes in the construction of live avian-human influenza A reassortant virus vaccines for use in humans. We determined the nucleotide sequences of the three polymerase gene segments of this virus. This completes the nucleotide sequence of the six transferrable genes of the avian donor virus. Comparison of the nucleotide and deduced amino acid sequences of the non-glycoprotein genes of the avian A/Mallard/78 virus with representative avian and human influenza A viruses suggests that the PB1 gene of H2N2 subtype human influenza A viruses may have been derived from a non-human, possibly avian influenza A virus by genetic reassortment. In addition, several regions of conserved amino acids with potential functional significance were identified in the deduced amino acid sequences of the polymerase proteins.

Amino Acid Sequence

Autotransplantation of splenic tissue after splenectomy in rats offers partial protection against intravenous pneumococcal challenge.

Thirty-six splenectomized Sprague-Dawley rats with omental implants of splenic tissue were challenged with intravenous pneumococci. The mortality rate in this group was compared to 31 similarly challenged splenectomized and 28 normosplenic rats. The results showed that while rats with implanted splenic tissue had a better survival rate (p = 0.04) than splenectomized rats, their survival was poorer than that of rats with normal spleens (p = 0.02) (Fischer's exact test).

Animals

Flow cytometric enumeration of absolute lymphocyte number in peripheral blood using two parameters of light scatter.

A method was developed to measure the absolute lymphocyte count (ALC) of whole blood using the Spectrum III automated flow cytometer. Ninety-nine samples of human peripheral blood were analysed on the Spectrum and the Coulter Counter S Plus II, to allow for comparison of the two machines. Regression analysis was used to test the extent of agreement between the sets of measurements on the two machines. The results demonstrated that the slope of the regression line was not significantly different from one, indicating a high level of correlation between Spectrum and Coulter ALC's. However, the mean difference between Coulter and Spectrum ALC's was not equal to zero, with the Spectrum giving counts approximately 10% lower than those of the Coulter machine. This is attributed to the different ways by which the two machines define a lymphocyte, the Spectrum III by two parameters of light scatter and the Coulter S Plus II by the single parameter of cell volume.

Flow Cytometry