PubMed Health⌕ Search

Biomedical subjects

B Ooms

Publications and source records attributed to B Ooms.

5 recordsLinked to original sources

High throughput therapeutic drug monitoring of clozapine and metabolites in serum by on-line coupling of solid phase extraction with liquid chromatography-mass spectrometry.

The characteristics of automated on-line solid phase extraction with liquid chromatography-mass spectrometry (SPE-LC-MS) are very amenable for flexibility and throughput in therapeutic drug monitoring (TDM). We demonstrate this concept of automated, on-line SPE-LC-MS for the analysis of clozapine and metabolites (desmethylclozapine and clozapine-N-oxide) in serum. Method development, optimisation and validation are described and a comparison with previously published methods for the determination of clozapine and metabolites in serum and plasma is made. Optimisation of chromatographic and SPE conditions for increased throughput resulted in SPE-LC-MS cycle times of only about 2.2 min, demonstrating the great potential of automated on-line SPE-LC-MS for TDM. The new method is shown to be clearly favourable, in particular in terms of ease of sample handling, throughput and detection limits. Recovery is essentially quantitative. Detection limits are at about 0.15-0.3 ng ml(-1), depending on the ionisation source used. Calibration follows a quadratic model for clozapine and its N-oxide and a linear model for the desmethyl metabolite (all cases: R > 0.99). Accuracy, evaluated at three concentration levels spanning the whole therapeutic range, shows that bias is less than 10%. Precision (intra - and inter assay) ranges from about 5% R.S.D. at the high end of the therapeutic range (700-1,000 ng ml(-1)) to about 20% R.S.D. (OECD defined limit) at the lower limit of quantitation ( approximately 50 ng ml(-1)). The lower limit of quantitation is well below the low end of the therapeutic range at 350 ng ml(-1).

Antipsychotic Agents↗

Profiling of tryptophan-related plasma indoles in patients with carcinoid tumors by automated, on-line, solid-phase extraction and HPLC with fluorescence detection.

BACKGROUND: Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. METHODS: Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. RESULTS: Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P <0.0001; r = -0.80). CONCLUSIONS: The present chromatographic approach reduces analytical variation and time needed for analysis and gives more detailed information about metabolic deviations in indole metabolism than do manual, single-component analyses.

5-Hydroxytryptophan↗

High throughput on-line solid phase extraction/tandem mass spectrometric determination of paclitaxel in human serum.

The feasibility of high throughput on-line solid phase extraction/tandem mass spectrometry (SPE/MS/MS) is tested for target analysis of paclitaxel in human serum. The use of a dual Prospekt system, with parallel SPE and elution directly to the mass spectrometer, resulted in a cycle time of 80 seconds for the entire, fully automated assay. The assay proved to be linear from 1 to 1000 ng/mL. Cartridges packed with small sorbent particles functioned both as SPE cartridges and as short analytical columns.

Blood Chemical Analysis↗

Fully automated sample handling system for liquid chromatography based on pre-column technology and automated cartridge exchange.

The design of an automated cartridge exchange module for on-line sample handling in liquid chromatography is described. When combined with a low-cost purge pump, a solvent selection valve and an auto-sampler, a fully automated sample handling system is obtained. Samples are sorbed on a disposable cartridge packed with 40 micron octyl-bonded silica, purged for clean-up and eluted on-line to the analytical column. Unattended operation of the system is demonstrated for various examples, i.e., the determination of anti-epileptic drugs in serum, an anti-cancer drug in plasma, barbiturates in urine, phenylurea herbicides in river water and caffeine in a soft drink.

Autoanalysis↗