PubMed Health⌕ Search

Biomedical subjects

B Reiner

Publications and source records attributed to B Reiner.

At least 19 recordsLinked to original sources

Canine borreliosis: a laboratory diagnostic trial.

The aim of this study was to investigate samples from dogs suggestive of active canine borreliosis (group A) by culture and PCR and the detection of antibodies against Borrelia burgdorferi sensu lato in order to confirm a presumptive clinical diagnosis of canine borreliosis by laboratory results. Criteria for such a diagnosis were: history of tick exposure, lameness, neurological signs, nephropathy, lethargy, anorexia, and fever. A total of 302 samples comprising EDTA blood, urine, synovial fluid, cerebrospinal fluid, and tissue (skin, synovial membrane, kidney) from 98 dogs (26 with arthritis, 46 with neurological signs, 21 with nephropathy, 5 with non-specific symptoms) were collected and examined. Moreover, 55 healthy dogs (group B) and 236 dogs with symptoms or injuries unlikely to be associated with borreliosis (group C) were included in this study. Blood serum samples collected from all individuals (n=389) were analysed by ELISA. Twenty-one (21%) out of 98 dogs from group A, 4 (7%) out of 55 from group B and 15 (6%) out of 236 dogs from group C were positive for antibodies against B. burgdorferi sensu lato. The seroprevalences between groups A, B and C differed significantly. None of the corresponding samples investigated by PCR and culture were positive for spirochetal DNA or viable spirochetes. Borrelia afzelii was grown from one EDTA-blood sample but the corresponding blood serum sample remained antibody-negative. Consequently, the etiologic role of B. afzelii in this case is unclear. In approximately 40% of the presumptive canine borreliosis cases, other lesions have been found to be responsible for clinical signs. This study affirms that a definitive diagnosis of canine borreliosis cannot be made by clinical symptoms and serology based on a single consultation. Moreover, this study clearly revealed that the diagnostic sensitivity is enhanced by a thorough consideration and exclusion of other diseases.

Animals↗

A novel technique using customised templates for the application of fractionated interstitial HDR brachytherapy to the tumour bed in soft-tissue sarcomas located in the extremities.

AIMS: Postoperative interstitial brachytherapy of limbs is challenging, because it is difficult to deliver a conformal dose to the tumour bed. We developed and assessed a new surgical fixation system for positioning guiding tubes in interstitial brachytherapy in order to achieve favourable geometry. MATERIALS AND METHODS: A 28-year-old patient was treated with postoperative interstitial brachytherapy boost followed by external radiotherapy after the 11th recurrence of a desmoid tumour in the forearm. On the basis of preoperative imaging data, customised resorbable templates made of polydioxanone (PDS) were cut to fit in the space left by the resected tumour. These were strategically positioned in the tumour bed during surgery. In order to hold the brachytherapy-guiding tubes parallel for the duration of treatment, they were passed through a series of holes bored into the templates. RESULTS: Fixing the guiding tubes with PDS templates resulted in a fixed geometry, and thus in an optimal dose distribution with only little additional dose optimisation needed by the brachytherapy treatment planning system. An optimised dose to the tumour bed, and a reduction of dose to critical normal tissues, is achievable with this template system for sarcomas located between osseous structures. CONCLUSION: The PDS templates offer a more rigid fixation of the guiding tubes in relation to the surrounding anatomy even after the operation cavity has been closed. A tailored dose distribution can be achieved, thus reducing possible side-effects. Additionally, because of the self-resorbable nature of the material, a re-operation for template removal is not necessary. The potential advantages of this method are being further investigated.

Adult↗

The Radiological Society of North America's Medical Image Resource Center: an update.

The Radiological Society of North America (RSNA) has initiated a long-term project called the Medical Image Resource Center (MIRC). The overall goal of the effort is to create an on-line library of medical images and related information and to maintain and index a number of other medical image resources. The rationale for the project, a summary of the overall requirements and objectives, and a finally a brief description of the future plans for MIRC are presented.

Computer Systems↗

Electronic teaching files: seven-year experience using a commercial picture archiving and communication system.

With the advent of electronic imaging and the internet, the ability to create, search, access, and archive digital imaging teaching files has dramatically improved. Despite the fact that a picture archival and communication system (PACS) has the potential to greatly simplify the creation of, archival, and access to a department or multifacility teaching file, this potential has not yet been satisfactorily realized in our own and most other PACS installations. Several limitations of the teaching file tools within our PACS have become apparent over time. These have, at our facility, resulted in a substantially reduced role of the teaching file tools for conferences, daily teaching, and research purposes. With the PACS at our institution, academic folders can only be created by the systems engineer, which often serves as an impediment to the teaching process. Once these folders are created, multiple steps are required to identify the appropriate folders, and subsequently save images. Difficulties exist for those attempting to search for the teaching file images. Without pre-existing knowledge of the folder name and contents, it is difficult to query the system for specific images. This is due to the fact that there is currently no fully satisfactory mechanism for categorizing, indexing, and searching cases using the PACS. There is currently no easy mechanism to save teaching, research, or clinical files onto a CD or other removable media or to automatically strip demographic or other patient information from the images. PACS vendors should provide much more sophisticated tools to create and annotate teaching file images in an easy to use but standard format (possibly Radiological Society of North America's Medical Image Resource Center [MIRC] format) that could be exchanged with other sites and other vendors' PAC systems. The privilege to create teaching or conference files should be given to the individual radiologists, technologists, and other users, and an audit should be kept of who has created these files, as well as keep track of who has accessed the files. Vendors should maintain a local PACS library of image quality phantoms, normal variants, and interesting cases and should have the capability of accessing central image repositories such as the RSNA's MIRC images. Commercial PAC systems should utilize a standard lexicon to facilitate the creation and categorization of images, as well as to facilitate sharing of images and related text with other sites. This should be combined with a very easy to use mechanism to write images and related text when appropriate onto removable media (while maintaining a high level of security and confidentiality) to make it easier to share images for teaching, research, or clinical purposes.

Computer-Assisted Instruction↗

Application service providers: an alternative approach to PACS implementation.

Several impediments have delayed the adoption of filmless imaging by the majority of radiology practitioners. These factors include concerns for technology obsolescence, limited available capital, and lack of existing information technology (IT) infrastructure and experienced personnel. Application service providers (ASPs) have begun to emerge as an alternative approach to the more traditional acquisition of picture archiving and communication (PAC) systems. This approach offers the prospective PACS customer the opportunity to outsource hardware, software, and IT services to a vendor on a fee-per-use basis. The ideal candidates for such an approach would be small to medium-sized hospitals with limited existing IT infrastructure. Using the ASP model, prospective PACS customers can purchase services unique to their needs and upgrade or expand these as needed. As ASP vendors increase their customer base, there is the potential for customers to achieve unique economies of scale not available through traditional financing means. This report discusses the economic and operational issues associated with ASPs, as well as potential limitations and future implications of this phenomenon.

Contract Services↗

The filmless radiology reading room: a survey of established picture archiving and communication system sites.

The purpose of this study was to survey radiologists experienced in soft-copy diagnosis using computer workstations about their current reading room environment, their impressions of the efficacy of their reading room design, and their recommendations based on their experience for improvement of the soft-copy reading environment. Surveys were obtained from radiologists at seven sites representing three major picture archiving and communication system (PACS) vendors throughout the world that have had extensive experience with soft-copy interpretation of radiology studies. The radiologists filled out a detailed survey, which was designed to assess their current reading room environment and to provide them with the opportunity to make suggestions about improvement of the PACS reading rooms. The survey data were entered into a database and results were correlated with multiple parameters, including experience with PACS, types of modalities interpreted on the system, and number of years of experience in radiology. The factors judged to be most important in promoting radiologist productivity were room lighting, monitor number, and monitor brightness. Almost all of the radiologists indicated that their lighting source was from overhead rather than indirect or portable light sources. Approximately half indicated they had the capability of dimming the brightness of the overhead lighting. Most radiologists indicated that they were able to adjust room temperature but that they did not have individual temperature controls at their workstations. The radiologists indicated that the most troublesome sources of noise included background noise, other radiologists, and clinicians much more than noise from computer monitors, technologists, or patients. Most radiologists did not have chairs that could recline or arm rests. Most did have wheels and the capability to swivel, both of which were judged important. The majority of chairs also had lumbar support, which was also seen to be important. Radiologists commonly adjusted room lighting and their reading chair, but rarely adjusted room temperature or monitor brightness. The median number of hours spent at the workstation before taken a "break" was 1.5. Common recommendations to improve the room layout included compartmentalization of the reading room and availability of the hospital/radiology information system at each workstation. The survey data suggest several areas of potential improvement based on radiologists' experience. Optimization of soft-copy reading room design is likely to result in decreased fatigue and increased productivity.

Attitude of Health Personnel↗

Transmission failure rate for computed tomography examinations in a filmless imaging department.

The purpose of the study was to determine the frequency and causes of unsuccessful computed tomography (CT) transmissions in a filmless imaging department and to determine the added efficiency gains provided by the sequential addition of modality worklist software and a major network upgrade. Prospective data on CT transmission error rates were recorded over an 18-month period. During the study interval, modality worklist functionality was added, followed by a network upgrade. Failed transmissions were categorized as to the source of the error (human v technical), and the specific problem encountered. Prior to the introduction of modality worklist software, the initial CT transmission failure rate was 7.6%, which was primarily the result of human error (69%), in the form of data entry error. Upon the introduction of modality worklist software, the transmission failure rate decreased to 3.5%, with human error accounting for only 16% of all failed transmissions. The subsequent addition of a network upgrade from shared Ethernet to switched Ethernet further reduced the transmission failure rate to 2.0%, which was believed to be the result of a reduction in the number of network collisions. Other sources of failed transmission occur at the levels of the CT scanner (network interface card), picture archiving and communication system (PACS)/hospital information system (HIS) interface, and modality gateway. When planning the transmission from film-based to filmless operation, one should consider various hardware, software, and infrastructural requirements to ensure successful PACS implementation. Software upgrades, in the form of modality worklist software, serve to improve technologist productivity by minimizing data entry error. Infrastructural changes, in the form of network upgrading, ensure proper dissemination of electronic data with decreased frequency of network collisions. Collectively, these improvements lead to enhanced transmission of digital images, resulting in productivity gains within the filmless CT department.

Computer Communication Networks↗

Adoption of alternative financing strategies to increase the diffusion of picture archiving and communication systems into the radiology marketplace.

The objective of the study was to evaluate current marketplace conditions and strategies employed by major picture archiving and communication systems (PACS) vendors in the creation of alternative financing strategies, to enhance the diffusion of filmless imaging. Data were collected from the major PACS vendors in the forms of survey questionnaires and review of existing leases. Topics evaluated in the survey included current financing options available, foreseeable changes in PACS financing, role of third-party financiers, and creation of risk-sharing arrangements. Generic leases were also reviewed evaluating the presence or absence of several key variables including technology obsolescence protection, hardware/software upgrades, end-of-term options, determination of fair market value, functionality/acceptance testing, uptime guarantees, and workflow management consulting. Eight of the 10 PACS vendors surveyed participated in the data collection. The vast majority of current PACS implementations (60% to 90%) occur through direct purchase, with conventional leasing (operating or capital) accounting for only 5% to 30% of PACS installations. The majority of respondents view fee-for-lease arrangements and other forms of risk sharing as increasing importance for future PACS financing. The specific targets for such risk-sharing arrangements consist of small hospital and privately owned imaging centers. Leases currently offered range in duration from 3 to 5 years and frequently offer technology obsolescence protection with upgrades, multiple end-of-term options, and some form of acceptance testing. A number of important variables frequently omitted from leases include uptime guarantees, flexibility in changing financing or vendors, and incorporation of expected productivity/operational efficiency gains. As vendors strive to increase the penetration of PACS into the radiology marketplace, there will be a shift from conventional financing (loan or purchase) to leasing. Fee-for-use leasing and other forms of risk sharing have the greatest potential in smaller hospitals, which do not have the financial resources to pursue conventional financing options. Potential PACS customers must be cautious when entering into these alternative financing strategies, to ensure that appropriate safeguards are incorporated, in order to minimize downside risk.

Cost Sharing↗

Understanding financing options for PACS implementation. Picture archiving and communication systems.

The acquisition of expensive equipment such as picture archiving and communication systems (PACS) becomes increasingly difficult as capital budgets become tighter. Traditional ownership financing options in the form of direct purchase or financing (loan) have several limitations including technology obsolescence, higher fixed pricing, limited options for equipment disposal, and the need to tie up valuable capital. Alternative financing options, in the form of conventional lease and risk sharing arrangements, offer several theoretical advantages including technology obsolescence protection in the form of built-in upgrades, preservation of borrowing power, multiple end-of-term options, and payment flexibility (which can be directly tied to realized productivity and operational efficiency gains). These options are discussed, with emphasis on the acquisition of PACS.

Capital Financing↗

Establishing benchmarks for creation of a pro-forma economic model to evaluate filmless PACS operation.

The purpose of this study was to establish data points (benchmarks) to incorporate into a pro-forma cost analysis model, comparing film-based and filmless modes of operation. Prospective data were collected over a 6-year period at the Baltimore VA Medical Center (BVAMC) immediately before and after implementation of a hospital-wide PACS. These data were in turn compared with local and national VA centers during comparable time periods, to establish reference data between manual film-based (without PACS) and filmless operations (using PACS). Benchmarks utilized for the study fell into 2 broad categories: operational costs and revenues generated. Factors contributing to operational costs include space requirements, equipment, supplies, personnel, and maintenance. Factors contributing to revenues generated included examination volume, modality mix, and reimbursement rates. Collectively, these data points were incorporated into a pro-forma model that allows prospective PACS customers to compare total cost of ownership for film-based and filmless operations dependent on the unique variables of the respective institution.

Benchmarking↗

[Radiation therapy in two cats with pituitary tumors].

Two cats with large pituitary neoplasms (adenoma and adenocarcinoma) were treated with fractionated radiation therapy. Total doses of 40 Gy, respectively 36 Gy, were applied in 10 fractions of 4 Gy, and 3.6 Gy respectively. Side effects were minimal and transient. Anesthesia was well tolerated. Improvement of clinical signs could be observed during radiation therapy in both cats. One cat had a complete, the other a partial tumor response. One cat (suspicion of adenoma) was euthanized 1 3/4 years after therapy due to unrelated disease. No tumor was found on histopathology, however a small focal necrosis of brain tissue in the irradiated field was observed. The second animal with a pituitary adenocarcinoma was euthanized because of tumor recurrence 1 1/2 years after therapy. Radiation therapy was effective, despite the low total doses of radiation applied.

Adenocarcinoma↗

Impact of filmless radiology on frequency of clinician consultations with radiologists.

OBJECTIVE: The purpose of the study was to determine the impact of filmless operation on the relative frequency of in-person consultations in the radiology department between radiologists and clinicians. CONCLUSION: The transition to filmless operation at the Baltimore Veterans Affairs Medical Center was associated with an 82% reduction in the in-person consultation rate for general radiography and a 44% reduction for cross-sectional imaging despite an increase in the volume of studies. The major reason for this decrease was the convenient access to current and prior images provided by the PACS (picture archiving and communication system). Radiology departments contemplating a transition to filmless operation should prepare for communication with clinicians to shift from being mostly in person to being conducted more and more through electronic forms of communication.

Baltimore↗

Computerized follow-up of discrepancies in image interpretation between emergency and radiology departments.

Radiographs are ordered and interpreted for immediate clinical decisions 24 hours a day by emergency physicians (EP's). The Joint Commission for Accreditation of Health Care Organizations requires that all these images be reviewed by radiologists and that there be some mechanism for quality improvement (QI) for discrepant readings. There must be a log of discrepancies and documentation of follow up activities, but this alone does not guarantee effective Q.I. Radiologists reviewing images from the previous day and night often must guess at the preliminary interpretation of the EP and whether follow up action is necessary. EP's may remain ignorant of the final reading and falsely assume the initial diagnosis and treatment were correct. Some hospitals use a paper system in which the EP writes a preliminary interpretation on the requisition slip, which will be available when the radiologist dictates the final reading. Some hospitals use a classification of discrepancies based on clinical import and urgency, and communicated to the EP on duty at the time of the official reading, but may not communicate discrepancies to the EP's who initial read the images. Our computerized radiology department and picture archiving and communications system have increased technologist and radiologist productivity, and decreased retakes and lost films. There are fewer face-to-face consultants of radiologists and clinicians, but more communication by telephone and electronic annotation of PACS images. We have integrated the QI process for emergency department (ED) images into the PACS, and gained advantages over the traditional discrepancy log. Requisitions including clinical indications are entered into the Hospital Information System and then appear on the PACS along with images on readings. The initial impression, time of review, and the initials of the EP are available to the radiologist dictating the official report. The radiologist decides if there is a discrepancy, and whether it is category I (potentially serious, needs immediate follow-up), category II (moderate risk, follow-up in one day), or category III (low risk, follow-up in several days). During the working day, the radiologist calls immediately for category I discrepancies. Those noted from the evening, night, or weekend before are called to the EP the next morning. All discrepancies with the preliminary interpretation are communicated to the EP and are kept in a computerized log for review by a radiologist at a weekly ED teaching conference. This system has reduced the need for the radiologist to ask or guess what the impression was in the ED the night before. It has reduced the variability in recording of impressions by EP's, in communication back from radiologists, in the clinical] follow-up made, and in the documentation of the whole QI process. This system ensures that EP's receive notification of their discrepant readings, and provides continuing education to all the EP's on interpreting images on their patients.

Emergency Service, Hospital↗

Strategies for the promotion of computer applications in radiology in healthcare delivery.

The objective of this paper is to identify current trends in the development and implementation of computer applications in today's ever-changing healthcare environment. Marketing strategies are discussed with the goal of promoting computer applications in radiology as a means to advance future healthcare acceptance of technologic developments from the medical imaging field. With the rapid evolution of imaging and and information technologies along with the transition to filmless imaging, radiologists must assume a proactive role in the development and application of these advancements. This expansion can be accomplished in a number of ways including internet based educational programs, research partnerships, and professional membership in societies such as the Society of Computer Applications in Radiology (SCAR). Professional societies such as SCAR, in turn, should reach out to include other professionals from the healthcare community. These would include financial, administrative, and information systems disciplines to promote these technologies in a cost conscious and value added manner.

Costs and Cost Analysis↗

Mycoplasma pneumoniae and Mycoplasma genitalium: a comparison of two closely related bacterial species.

The rapid progress in sequencing large quantities of DNA will provide an increasing number of complete genome sequences of closely related bacterial species as well as of pairs of isolates from the same species with different features, such as a pathogenic and an apathogenic representative. This opens the way to apply subtractive comparative analysis as a tool to select from the large pool of all bacterial genes a relatively small set of genes that can be correlated with the expression of a certain phenotype. These selected genes can then be the target for further functional analyses.

Bacterial Proteins↗

[Snake bites in dogs].

Altogether 11 cases of stings in dogs are reported. In at least nine cases, common vipers (Vipera berus) were identified to be the causes. The most frequently observed symptoms were haemorrhagic and oedematous inflammations of the area of the wounds, furthermore haemolysis and intense leukocytosis with relative and absolute neutrophilia and in some cases shock symptoms. One dog died 17 days after the accident from multiple organ insufficiencies, all the other dogs improved. As a therapy, bandage of the injured limb, quieting of the dog, snake antitoxin, corticosteroids, antihistaminics, antibiotics, and symptomatic therapy depending on the clinical signs are recommended.

Adrenal Cortex Hormones↗

Comparative analysis of the genomes of the bacteria Mycoplasma pneumoniae and Mycoplasma genitalium.

The sequenced genomes of the two closely related bacteria Mycoplasma genitalium and Mycoplasma pneumoniae were compared with emphasis on genome organization and coding capacity. All the 470 proposed open reading frames (ORFs) of the smaller M.genitalium genome (580 kb) were contained in the larger genome (816 kb) of M.pneumoniae. There were some discrepancies in annotation, but inspection of the DNA sequences showed that the corresponding DNA was always present in M. pneumoniae. The two genomes could be subdivided into six segments. The order of orthologous genes was well conserved within individual segments but the order of these segments in both bacteria was different. We explain the different organization of the segments by translocation via homologous recombination. The translocations did not disturb the continuous bidirectional course of transcription in both genomes, starting at the proposed origin of replication. The additional 236 kb in M.pneumoniae,compared with theM.genitalium genome, were coding for 209 proposed ORFs not identified in M.genitalium. Of these ORFs, 110 were specific to M.pneumoniae exhibiting no significant similarity to M.genitalium ORFs, while 76 ORFs were amplifications of ORFs existing mainly as single copies in M. genitalium. In addition, 23 ORFs containing a copy of either one of the three repetitive DNA sequences RepMP2/3, RepMP4 and RepMP5 were annotated in M.pneumoniae but not in M.genitalium,although similar DNA sequences were present. TheM.pneumoniae-specific genes included a restriction-modification system, two transport systems for carbohydrates, the complete set of three genes coding for the arginine dihydrolase pathway and 14 copies of the repetitive DNA sequence RepMP1 which were part of several different translated genes with unknown function.

Base Composition↗