Isoflurane concentrations using uncompensated vaporisers within circle systems.

In a series of studies designed to investigate the need for a temperature-compensated vaporiser for use in a circle system, we first studied temperature changes within and isoflurane concentration delivered by a Komesaroff vaporiser during bench tests using different gas flows. Agent temperature and vapour concentration decreased as predicted by the Antoine equation. Using the vaporiser within a circle system during clinical anaesthesia, we then studied 20 patients breathing spontaneously and a further 10 patients receiving controlled ventilation, measuring the temperature of the agent within the vaporiser and the concentration of agent inspired by a the patient. In clincial use with the frest gas flows of 1-3.min-1, the inspired agent concentration did not decrease despite the decrease in temperature of the liquid isoflurane in the vaporiser.

Anesthesia, Closed-Circuit↗

Respiratory feedback effects on vaporisers in circle systems.

We studied a group of spontaneously breathing patients anaesthetised for routine orthopaedic surgery using a circle system and isoflurane in a Komesaroff vaporiser within the circle. We observed and recorded: (1) the change in inspired isoflurane concentration caused by changing the fresh gas flow, (2) the increased respiration produced by surgical stimulus and the resulting increase in isoflurane concentration, (3) the respiratory depression produced by opioids and the consequent decrease in isoflurane concentration. We consider this regulation of anaesthetic uptake by the patient to be beneficial.

Analgesics, Opioid↗

Controlled ventilation using isoflurane with an in-circle vaporiser.

We studied 19 patients anaesthetised for routine surgery using isoflurane delivered from a Komesaroff vaporiser mounted within a circle system. Their lungs were ventilated using a Penlon Nuffield ventilator attached to the circle system by a trunk of tubing. Fresh gas flow rates of 1, 2 or 31.min-1 were used. The inspired agent concentration was measured using a Datex Ultima multigas analyser and was found to be stable and easily controlled.

Anesthesia, Closed-Circuit↗

Comparison of oxygen consumption measurements: indirect calorimetry versus the reversed Fick method.

OBJECTIVE: To compare measurement of oxygen consumption (VO2) by spirometry and the reversed Fick method. DESIGN: Within-patient comparison using simultaneous measurements by the two methods, one previously calibrated on a metabolic simulator. PATIENTS: Twenty sets of observations on eight patients (57 to 83 yrs) requiring mechanical ventilation in a critical care unit. INTERVENTIONS: None during or immediately before the measurements. MEASUREMENTS AND MAIN RESULTS: Duplicate pairs of measurements of VO2 were made with a previously validated spirometric technique and the reversed Fick method (Qt[CaO2 - CVO2]), where Qt is cardiac output, CaO2 is arterial oxygen content, and CVO2 is mixed venous oxygen content. The coefficient of variation of the difference between duplicate measurements by the former technique was only 2.53% compared with 10.4% for the latter. The mean VO2 measurement by the spirometric method was 285.7 +/- 40.7 (SD) mL/min standard temperature and pressure, dry (STPD) and for the reversed Fick method, the mean VO2 measurement was 249.3 +/- 38.5 mL/min STPD. The mean difference was 36.4 +/- 28.5 mL/min STPD (p less than .001). CONCLUSIONS: The repeatability of the spirometric method was four times better than the reversed Fick method. The latter gave a significantly lower value that probably, in part, reflects the VO2 of the lung, which is included in the spirometric method but not in the reversed Fick measurement.

Aged↗

Evaluation of metabolic measuring instruments for use in critically ill patients.

We evaluated three commercial indirect calorimetry devices which are used during artificial ventilation. Commercial butane, which had an RQ of 0.615, consumes 6.40 ml oxygen, and produces 3.94 ml CO2/1 ml, was burned in a gas-tight combustion chamber in conjunction with the ventilation of a lung model. During combustion, the flow rate of butane was measured with a soapfilm flowmeter for the calculation of reference values of oxygen consumption (VO2) and CO2 production (VCO2). To investigate the effect of oxygen concentration on the accuracy of these instruments, measurements were carried out at FIO2 values of 0.3, 0.4, 0.5, and 0.6 with a fixed ventilation mode (tidal volume 500 ml; respiratory rate 16 breath/min, intermittent positive-pressure ventilation). For the Datex Deltratrac Metabolic Monitor, the mean relative errors of measured VO2, VCO2, and RQ were all within 4.0%, 2.9%, and 4.0%, respectively. For the Engstrom Metabolic Computer, the corresponding values were 1.4%, 5.7%, and 6.0%, and for the SensorMedics MMC Horizon, 5.7%, 2.9%, and 5.9%.

Calorimetry↗

Validation of oxygen consumption measurements during artificial ventilation.

We describe a system for the absolute calibration of indirect calorimeters, under the conditions of artificial ventilation and increased inspired O2 concentration, in which butane, at a measured flow rate, is burned downstream of an artificial lung. One milliliter of butane requires 6.4 ml O2 for its combustion, and the respiratory quotient is 0.615. With the closed-circuit O2-replenishment method there was no significant systematic error in the measurement of either O2 consumption or CO2 output and a random error with a SD of 8.3 ml/min for O2 consumption and 6.3 ml/min for CO2 output. There were no significant differences in the errors with inspired O2 concentrations between 23.8 and 59.5% and O2 consumptions between 89 and 366 ml/min.

Butanes↗