Modelling the impact of blood flow on the temperature distribution in the human eye and the orbit: fixed heat transfer coefficients versus the Pennes bioheat model versus discrete blood vessels.

Prediction of the temperature distribution in the eye depends on how the impact of the blood flow is taken into account. Three methods will be compared: a simplified eye anatomy that applies a single heat transfer coefficient to describe all heat transport mechanisms between the sclera and the body core, a detailed eye anatomy in which the blood flow is accounted for either by the bioheat approach, or by including the discrete vasculature in the eye and the orbit. The comparison is done both for rabbit and human anatomies, normo-thermally and when exposed to homogeneous power densities. The first simplified model predicts much higher temperatures than the latter two. It was shown that the eye is very hard to heat when taking physiological perfusion correctly into account. It was concluded that the heat transfer coefficient describing the heat transport from the sclera to the body core reported in the literature for the first simplified model is too low. The bioheat approach is appropriate for a first-order approximation of the temperature distribution in the eye when exposed to a homogeneous power density, but the discrete vasculature down to 0.2 mm in diameter needs to be taken into account when the heterogeneity of the temperature distribution at a mm scale is of interest.

Animals↗

Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue-air interfaces in a lateral magnetic field due to returning electrons.

In the framework of the development of the integration of a MRI-scanner with a linear accelerator, the influence of a lateral, magnetic field on the dose distribution has to be determined. Dose increase is expected at tissue-air boundaries, due to the electron return effect (ERE): electrons entering air will describe a circular path and return into the phantom causing extra dose deposition. Using IMRT with many beam directions, this exit dose will not constitute a problem. Dose levels behind air cavities will decrease because of the absence of electrons crossing the cavity. The ERE has been demonstrated both by simulation and experiment. Monte Carlo simulations are performed with GEANT4, irradiating a water-air-water phantom in a lateral magnetic field. Also an air tube in water has been simulated, resulting in slightly twisted regions of dose increase and decrease. Experimental demonstration is achieved by film measurement in a perspex-air-perspex phantom in an electromagnet. Although the ERE causes dose increase before air cavities, relatively flat dose profiles can be obtained for the investigated cases using opposite beam configurations. More research will be necessary whether this holds for more realistic geometries with the use of IMRT and whether the ERE can be turned to our advantage when treating small tumour sites at air cavities.

Body Burden↗

Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field.

Integrating magnetic resonance imaging (MRI) functionality with a radiotherapy accelerator can facilitate on-line, soft-tissue based, position verification. A technical feasibility study, in collaboration with Elekta Oncology Systems and Philips Medical Systems, led to the preliminary design specifications of a MRI accelerator. Basically the design is a 6 MV accelerator rotating around a 1.5 T MRI system. Several technical issues and the clinical rational are currently under investigation. The aim of this paper is to determine the impact of the transverse 1.5 T magnetic field on the dose deposition. Monte Carlo simulations were used to calculate the dose deposition kernel in the presence of 1.5 T. This kernel in turn was used to determine the dose deposition for larger fields. Also simulations and measurements were done in the presence of 1.1 T. The pencil beam dose deposition is asymmetric. For larger fields the asymmetry persists but decreases. For the latter the distance to dose maximum is reduced by approximately 5 mm, the penumbra is increased by approximately 1 mm, and the 50% isodose line is shifted approximately 1 mm. The dose deposition in the presence of 1.5 T is affected, but the effect can be taken into account in a conventional treatment planning procedure. The impact of the altered dose deposition for clinical IMRT treatments is the topic of further research.

Computer Simulation↗

A six-bank multi-leaf system for high precision shaping of large fields.

In this study, we present the design for an alternative MLC system that allows high precision shaping of large fields. The MLC system consists of three layers of two opposing leaf banks. The layers are rotated 60 degrees relative to each other. The leaves in each bank have a standard width of 1 cm projected at the isocentre. Because of the symmetry of the collimator set-up it is expected that collimator rotation will not be required, thus simplifying the construction considerably. A 3D ray tracing computer program was developed in order to simulate the fluence profile for a given collimator and used to optimize the design and investigate its performance. The simulations show that a six-bank collimator will afford field shaping of fields of about 40 cm diameter with a precision comparable to that of existing mini MLCs with a leaf width of 4 mm.

Computer Simulation↗

A feasibility study of interstitial hyperthermia plus external beam radiotherapy in glioblastoma multiforme using the Multi ELectrode Current Source (MECS) system.

PURPOSE: Thermoradiotherapy has been shown in several randomized trials to increase local control compared to radiotherapy alone. The first randomized study of interstitial hyperthermia in glioblastoma multiforme showed a survival benefit for hyperthermia, though small. Improvement of the heating technique could lead to improved results. The purpose of this feasibility study is to present the clinical and thermal data of application of an improved interstitial hyperthermia system. METHODS AND MATERIALS: Six patients with a glioblastoma multiforme were treated with interstitial hyperthermia using the Multi Electrode Current Source Interstitial Hyperthermia (MECS-IHT) system. The MECS-IHT system has the capability of spatial monitoring of temperature and individually steering of heating electrodes. Three sessions were given aiming at a steady state temperature of 42 degrees C for 1 h, with an interval of 3-4 days, during an external irradiation scheme of 60 Gy in 6 weeks. Hyperthermia was delivered with a mean of 10 catheters, 18 heating electrodes and 38 thermal probes per patient. RESULTS: Sub-optimal temperatures were encountered in the first two patients leading to adjustments in technique thereafter with subsequent improvement of thermal data. With a catheter spacing of 11-12 mm, measurements yielded a mean T(90), T(50) and T(10) of 39.9, 43.7 and 45.2 degrees C, respectively, over three sessions in the last patient. The power per electrode to reach this temperature distribution varied from 25-100% of full power in each of the last four patients. Thermal data were reproducible over the three sessions. Acute toxicity was minimal. CONCLUSIONS: Despite the spatial steering capabilities of the MECS-IHT system, a large temperature heterogeneity was encountered. The heterogeneity was the reason to limit the catheter spacing to 11-12 mm, thus making only small tumour volumes feasible for interstitial heating.

Aged↗

Radiotherapy and hyperthermia in the treatment of patients with locally advanced prostate cancer: preliminary results.

OBJECTIVE: To report an interim clinical evaluation of combined external beam irradiation (EBRT) and interstitial or regional hyperthermia in the treatment of locally advanced prostate cancer. PATIENTS AND METHODS: From 1997 to 2001, 26 patients with T3-4/NX/0M0 prostate carcinoma were treated with a combination of conformal EBRT and hyperthermia. Fourteen patients received five weekly regional hyperthermia treatments within an optimization (phase II) study, using the coaxial transverse electrical magnetic system. Twelve patients received one interstitial hyperthermia treatment within a feasibility study (phase I), using the multi-electrode current source system. Irradiation was delivered using a conformal three-field technique, administering 70 Gy in 2-Gy fractions in 7 weeks. RESULTS: The mean initial prostate-specific antigen level was 26 ng/mL. Three patients had a T4 and 23 a T3 tumour; the tumours were classified as well (four), moderately (16) and poorly (six) differentiated. The mean follow-up was 36 months. In the combined treatments there was no toxicity of more than grade 2. In regional hyperthermia the mean index temperature (T90 and T50, i.e. exceeded by 90% and 50% of the measurements) was 40.2 degrees C and 40.8 degrees C, and for interstitial hyperthermia 39.4 degrees C and 41.8 degrees C, respectively. All patients survived; seven patients had a biochemical relapse (27%), three in the regional and four in the interstitial group. The actuarial probability of freedom from biochemical relapse was 70% at 36 months for all patients together, 79% for regional and 57% for interstitial. No factors were found that could be used to predict relapse. CONCLUSIONS: The clinical outcome in these patients with advanced localized prostate cancer seems to compare favourably with most series using irradiation alone, and the treatment caused no severe complications.

Aged↗

Determination and validation of the actual 3D temperature distribution during interstitial hyperthermia of prostate carcinoma.

To determine the thermal dose of a hyperthermia treatment, knowledge of the three-dimensional (3D) temperature distribution is mandatory. The aim of this paper is to validate an interstitial hyperthermia treatment planning system with which the full 3D temperature distribution can be obtained in individual patients. Within a phase I study, 12 patients with prostate cancer were treated with interstitial hyperthermia using our multi electrode current source interstitial hyperthermia treatment (MECS IHT) system. The temperature distribution was measured from within the heating devices and by additional thermometry. The perfusion level was estimated and the heating implant reconstructed. The steady-state temperature distribution was calculated using our interstitial hyperthermia treatment planning system. The simulated temperature distribution was validated by individually comparing the measured and simulated thermo-sensors, both for the thermometry integrated with the heating applicators and the additional thermometry. The entire procedure was also performed on a no-flow agar-agar phantom. It was shown that the calculated temperature distribution of an individual patient during MECS interstitial hyperthermia is very heterogeneous. The validation indicates that the calculated temperature elevations match the measurements within approximately 1 degrees C. Possible improvements are more precise reconstruction, incorporation of discrete vasculature and using a temperature-dependent, heterogeneous perfusion distribution. Further technical improvements of the MECS-IHT system may also result in better temperature calculations.

Agar↗

Discretizing large traceable vessels and using DE-MRI perfusion maps yields numerical temperature contours that match the MR noninvasive measurements.

The success of hyperthermia treatments is dependent on thermal dose distribution. However, the three-dimensional temperature distribution remains largely unknown. Without this knowledge, the relationship between thermal dose and outcome is noisy, and therapy cannot be optimized. Accurate computations of thermal distribution can contribute to an optimized therapy. The hyperthermia modeling group in the Department of Radiotherapy, University Medical Center Utrecht devised a Discrete Vasculature [Kotte et al., Phys. Med. Biol. 41, 865-884 (1996)] model that accounts for the presence of vessel trees in the computational domain. The vessel tree geometry is tracked using magnetic resonance (MR) angiograms to a minimum diameter between 0.6 and 1 mm. However, smaller vessels (0.2-0.6 mm) are known to account for significant heat transfer. The hyperthermia group at Duke University Medical Center has proposed using perfusion maps derived from dynamic-enhanced magnetic resonance imaging to account for the tissue perfusion heterogeneity [Craciunescu et al., Int. J. Hyperthermia 17, 221-239 (2001)]. In addition, techniques for noninvasive temperature measurements have been devised to measure temperatures in vivo [Samulski et al., Int. J. Hypertherminal, 819-829 (1992)]. In this work, a patient with high-grade sarcoma has been retrospectively modeled to determine the temperature distribution achieved during a hyperthermia treatment. Available for this model were MR depicted geometry, angiograms, perfusion maps, as necessary for accurate thermal modeling, as well as MR thermometry data for validation purposes. The vasculature assembly through modifiable potential program [Van Leeuwen et al., IEEE Trans. Biomed. Eng. 45, 596-604 (1998)] was used in order to incorporate the traceable large vessels. Temperature simulations were made using different approaches to describe perfusion. The simulated cases were the bioheat equation with constant perfusion rates per tissue type, perfusion maps alone, tracked vessel tree and perfusion maps, and generated vessel tree. The results were compared with MR thermometry data for a single patient data set, concluding that a combination between large traceable vessels and perfusion map yields the best results for this particular patient. The technique has to be repeated on several patients, first with the same type of malignancy, and after that, on patients having malignancies at other different sites.

Algorithms↗

How to apply a discrete vessel model in thermal simulations when only incomplete vessel data are available.

For accurate predictions of the temperature distribution during hyperthermia treatment a thermal model should incorporate the individual impact of discrete vessels. In clinical practice not all vessels can be reconstructed individually. This paper investigates five possible strategies to model the thermal impact of these missing vessels. A tissue volume with a detailed, realistic, counter-current discrete vasculature is heated and the steady-state temperature distribution is calculated using our Discrete Vasculature (DIVA) thermal model. To mimic incomplete discrete vasculatures the full tree is gradually stripped, that is, the number of discretely described vessels is reduced in four steps until no discrete vessels are left. At each strip level the steady state temperature distribution is calculated for five different strategies to model the missing vessels. The strategies all use a local or global heat sink model in addition to the discrete vasculature. The resulting temperature distributions are compared with the full tree simulation. With increasing strip level the correspondence with the full tree simulation deteriorated for all strategies. An optimal strategy was found to model the missing vessels depending on the available angiographic data. It was also found that simulations with a decreased number of discrete vessels, or no vessels at all, yield temperatures which are too high. Theoretically this can be compensated by increasing the thermal conductivity; finding the optimal value is done empirically.

Blood↗

Modelling individual temperature profiles from an isolated perfused bovine tongue.

To predict the temperature distribution during hyperthermia treatments a thermal model that accounts for the thermal effect of blood flow is mandatory. The DIscrete VAsculature (DIVA) thermal model developed at our department is able to do so; geometrically described vessels are handled individually and the remaining vasculature is modelled collectively. The goal of this paper is to experimentally validate the DIVA model by comparing measured with modelled temperature profiles on an individual basis. Temperature profiles in an isolated bovine tongue heated with three hot water tubes were measured at three controlled perfusion levels, 0, 6 and 24 ml (100 g)(-1) min(-1). The geometries of the tongue, the hot water tubes, thermocouples and discrete vasculature down to 0.5 mm diameter were reconstructed by using cryo-microtome slices at 0.1 mm cubic resolution. This reconstruction of the experimental set-up is used for the modelling of individual profiles. In a no-flow agar-agar phantom, DIVA showed nearly perfect correspondence between measurements and simulations. In the isolated bovine tongue the correspondence at no flow was slightly disturbed due to geometrical distortion in the reconstruction of the experimental set-up. Measurements showed decreasing temperature profiles with increasing perfusion. DIVA correctly predicted this decrease in temperature as well as the thermal impact of a large vessel close to a thermocouple. Blood flow was modelled using discrete vasculature and using a heat sink model. Although at 24 ml (100 g)(-1) min(-1) correspondence between heat sink simulations and measurements was reasonable, modelling discrete vasculature yielded the best correspondence at both 6 and 24 ml (100 g)(-1) min(-1). The results strongly suggest that with accurate data acquisition DIVA can predict temperature profiles on an individual basis. For this kind of patient-specific treatment planning in the clinic, geometrical reconstruction of the anatomy, vasculature and the heating implant is necessary. MRI is capable of providing these data. Further research will be done on thermal simulations of actual clinical hyperthermia treatments.

Agar↗

Temperature simulations in tissue with a realistic computer generated vessel network.

The practical use of a discrete vessel thermal model for hyperthermia treatment planning requires a number of choices with respect to the unknown part of the patient's vasculature. This work presents a study of the thermal effects of blood flow in a simple tissue geometry with a detailed artificial vessel network. The simulations presented here demonstrate that an incomplete discrete description of the detailed network results in a better prediction of the temperature distribution than is obtained using the conventional bio-heatsink equation. Therefore, efforts to obtain information on the positions of the large vessels in an individual hyperthermia patient will be rewarded with a more accurate prediction of the temperature distribution.

Arteries↗

Comparison of temperature distributions in interstitial hyperthermia: experiments in bovine tongues versus generic simulations.

Temperature distributions resulting from hyperthermia treatments on isolated perfused bovine tongues were compared with simulations by a treatment planning system. The aim was to test whether the discrete vessel model used for the treatment planning is able to predict correct generic temperature distributions. Tongues were heated with the multielectrode current source interstitial hyperthermia treatment (MECS IHT) system, while the steady-state temperature distribution was mapped by scanning 10 thermocouples along paths perpendicular to the interstitial implant. For simulations a tongue was defined with generic discrete vasculature and an electrode implant analogue to the experiments. To model vascular generations not described discretely, a local heatsink was implemented at the end of each terminating branch. The discretely modelled vasculature showed itself on the temperature distributions in two ways. Individual vessels caused very local, sharp wells in the tracked temperature profiles. In the presence of large vessels a collective behaviour was also seen, i.e. a regional lowering of temperature. Both phenomena can be recognized in the experimentally obtained temperature distributions too. Predicting correct generic temperature distributions is feasible with the discrete vessel model used.

Animals↗

Treatment planning of brain implants using vascular information and a new template technique.

A new template technique has been developed for implanting hyperthermia catheters in the treatment of brain tumors. The technique utilizes an imaging template and a drill template which can be rigidly secured to the head with three skull screws. The anatomic and vascular information needed for hyperthermia treatment planning may be assessed with three-dimensional magnetic resonance (MR) imaging and angiography acquisitions which use a surface coil. In the companioning treatment planning system the catheter positions and lengths and the electrodes in the catheter can be interactively manipulated relative to the anatomy and vasculature. The visualization of the blood vessels relative to the template allows the minimization of the risk on intracranial hemorrhages. This template technique is useful for any brain tumor implants, especially when a large number of catheters are involved. A phantom test has shown that this procedure has an accuracy in the order of 1 mm provided that the MR-related geometry distortions are minimized.

Brain Neoplasms↗