PubMed Health⌕ Search

Biomedical subjects

Bojeong Kim

Publications and source records attributed to Bojeong Kim.

2 recordsLinked to original sources

Capillary electrophoresis of trace metals in highly saline physiological sample matrices.

Trace metal ions in highly saline samples such as urine were determined with capillary electrophoresis (CE) without desalting or off-line preconcentration. By mixing with a dye, 4-(2-pyridylazo) resorcinol (PAR), the metal ions were converted into anionic complexes having strong absorbance near 500 nm. A large volume of the metal-PAR complex sample solution injected into a coated capillary was stacked isotachophoretically and separated under a reverse potential. The salt anion (chloride) and PAR in the sample matrix acted as the leading and terminating electrolytes, respectively. In a sample containing a 250 mM NaCl matrix, more than 400-fold enhancement in the absorbance detector response was realized compared to the normal CE injection mode. Combination of the dye complexation and isotachophoretic stacking provided excellent detection limits (S/N = 3) for three trace metal ions in the low ppb range (Fe(2+), 0.7 ppb, Ni(2+), 0.4 ppb; Zn(2+), 1.2 ppb) with absorbance detection. The migration time reproducibility was excellent (relative standard deviations: standard samples < 1%, urine samples approximately 1%). The proposed method is convenient and fast, and the sample analysis can be completed within 20 min.

Animals↗

Large-volume stacking in capillary electrophoresis using a methanol run buffer.

Highly sensitive nonaqueous capillary electrophoresis of weakly acidic organic compounds has been performed using methanol as the run buffer solvent. Methanol provided appropriate suppression of the electroosmotic flow and an increase in the electrophoretic mobilities of anionic solutes compared to water. These two effects allowed large-volume stacking using the electroosmotic flow pump (LVSEP) to be achieved for larger anions using a bare fused-silica capillary under an electric field of reverse polarity, whereas only fast-moving small anions were previously known to be suitable for LVSEP in aqueous media. A field-enhanced sample injection of an additional amount of analytes during the solvent plug removal further enhanced the limits of detection to below the nanomolar range with conventional UV absorption detection. Under optimum conditions, excellent linear responses and reproducibility in the migration times together with the corrected peak areas for ten analytes were obtained in the concentration range of 10-100 nM.

Buffers↗