Large-volume stacking in capillary electrophoresis using a methanol run buffer.

Abstract

Highly sensitive nonaqueous capillary electrophoresis of weakly acidic organic compounds has been performed using methanol as the run buffer solvent. Methanol provided appropriate suppression of the electroosmotic flow and an increase in the electrophoretic mobilities of anionic solutes compared to water. These two effects allowed large-volume stacking using the electroosmotic flow pump (LVSEP) to be achieved for larger anions using a bare fused-silica capillary under an electric field of reverse polarity, whereas only fast-moving small anions were previously known to be suitable for LVSEP in aqueous media. A field-enhanced sample injection of an additional amount of analytes during the solvent plug removal further enhanced the limits of detection to below the nanomolar range with conventional UV absorption detection. Under optimum conditions, excellent linear responses and reproducibility in the migration times together with the corrected peak areas for ten analytes were obtained in the concentration range of 10-100 nM.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bojeong Kim, Doo Soo Chung. 2002. Large-volume stacking in capillary electrophoresis using a methanol run buffer.. https://doi.org/10.1002/1522-2683(200201)23%3A1%3C49%3A%3Aaid-elps49%3E3.0.co%3B2-s

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Analysis of secretory immunoglobulin A in human saliva by laser-induced fluorescence capillary electrophoresis.

The utility of capillary electrophoresis (CE) has been demonstrated for the analysis of secretory immunoglobulin A (sIgA) in human saliva. The amount of sIgA in saliva correlates with immune status. For detecting salivary sIgA, laser-induced fluorescence was conducted in this report for signal amplification. sIgA and anti-sIgA antibody were labeled with cyanine fluorescence (Cy5) for competitive immunoassay and non-competitive analysis, respectively. Cy5 was excited by He-Ne laser with a wavelength of 635 nm, with maximum emission at 670 nm. Migration time during electrophoresis depended on whether sIgA-Cy5 was mixed with antibody or anti-sIgA-Cy5 mixed with sIgA to form Ag-Ab complex. The results indicated that CE competitive immunoassay was effective for analyzing serum sIgA, but not for salivary sIgA. However, salivary sIgA can be analyzed by complex formation assay. The peak area of the complex was proportional to the amount of sIgA added. A standard linear regression curve was generated using purified sIgA. From this standard curve, the amount of sIgA from saliva of either normal or immunocompromised patients can be calculated from the Ag-Ab complex peak area.

Buffers↗

Nanoparticles bearing polyethyleneglycol-coupled transferrin as gene carriers: preparation and in vitro evaluation.

The aims of this work were to determine the stability of pDNA against various conditions during microencapsulation, prepare transferrin (TF)-conjugated PEGylated polycyanoacrylate nanoparticles (TF-PEG-nanoparticles), and assess its physicochemical characteristics and in vitro targeting cells association. The open circular forms of pDNA obviously increased when pDNA was emulsified into organic solution under sonification. When pDNA solution (pH 7.0) contained 1, 3 or 5% (w/v) PVA, after sonification, average 48.2, 59.4 and 62.1% of double-supercoiled DNA (dsDNA) were preserved, respectively. When medium of pDNA was 0.9% NaCl (pH 7.0), 0.1M NaHCO(3) (pH 8.0) or phosphate buffer (pH 8.0), average 53.1, 69.3 and 56.9% of dsDNA remained after sonification, respectively. Poly(aminopoly(ethylene glycol)cyanoacrylate-co-hexadecyl cyanoacrylate) (poly(H(2)NPEGCA-co-HDCA)) showed a slight influence on pDNA in 0.1M NaHCO(3) (pH 8.0) when its concentration increased from 0.5 to 4% (w/v). TF-PEG-nanoparticles loading pDNA were spherical in shape with size under 200nm and entrapment efficiency 35-50%. 0.1M NaHCO(3) with 3% PVA (w/v) could largely reduce the damage of pDNA during microencapsulation. TF-PEG-nanoparticles bore 1-3% of the total PEG chains conjugated to TF molecules, and exhibited the burst effect with over 30% drug release within 1 day. After the first phase, pDNA release profiles displayed a sustained release. The amount of cumulated pDNA release over 7 days was: 86.3, 81.5 and 74.4% for 1, 2 and 4% polymer nanoparticles, respectively. The degree of target K562 cell binding of TF-PEG-nanoparticles was greater than that of non-targeted PEG-nanoparticles at 4 degrees C. The presence of free TF decreased significantly the degree of cell binding of TF-PEG-nanoparticles, which revealed that the binding of TF-PEG-nanoparticles to K562 cells was indeed receptor specific. These results suggested that TF-PEG-nanoparticles were useful for delivery of pDNA to target cells.

Buffers↗

Degradation kinetics of mometasone furoate in aqueous systems.

Mometasone furoate (MF) is a synthetic glucocorticoid. There is little information available on the stability of MF and no degradation products have been unequivocally identified. Thus, the primary objective of this study was to characterize the degradation of MF, qualitatively and quantitatively. Stability of MF decreased with increasing pH (>4) and decreasing ionic strength in aqueous media. The chemical stability of MF in aqueous systems was significantly dependent on pH. MF appeared to be stable at pH < 4 but degraded to four products at higher pH. The degradation of MF in aqueous solutions follows pseudo-first-order kinetics and involved a series of parallel and consecutive reactions. The turnover of MF and its products appears to be catalyzed by the hydroxide ion. The pH dependence of these reactions should be considered, when formulating or extemporaneously compounding MF formulations. An optimal pH of stability was below pH 4. The changes in pH, however, do not appear to be the only factor of importance, since an increase in ionic strength and buffer concentration displayed a stabilizing effect on this glucocorticoid in the buffers tested. Trace metal ions are unlikely to be involved in degradation of MF in aqueous solution.

Buffers↗