Quantification of serine enantiomers in rat brain microdialysate using Marfey's reagent and LC/MS/MS.

The ability to selectively measure serine enantiomer concentrations in rat brain microdialysate is essential during drug discovery to study the interaction of d-serine with the N-methyl-d-aspartate (NMDA) subtype of the glutamate receptor. NMDA receptor-stimulating agents, such as d-serine, have been shown to reduce the negative symptoms and cognitive dysfunction in individuals with schizophrenia when added to conventional or atypical antipsychotic drug regimens. In the work presented here, an LC/MS/MS assay was developed and validated to simultaneously measure d-serine and l-serine concentrations in rat brain microdialysate. Reverse phase chromatographic resolution of the enantiomers was obtained through derivatization with 1-fluoro-2,4-dinitrophenyl-5-l-alanine amide (Marfey's reagent). The assay was validated to determine concentrations over the range of 10-7500 ng/mL using electrospray ionization and multiple reaction monitoring (MRM). Both intra- and inter-day precision and accuracy were less than 16.5% (RE) and 7% (CV) for both analytes, respectively, and assay throughput was increased significantly relative to existing methodologies.

Alanine↗

Liquid chromatography/tandem mass spectrometry characterization of oxidized amyloid beta peptides as potential biomarkers of Alzheimer's disease.

Alzheimer's disease is characterized by the deposition of senile plaques that consist primarily of amyloid beta peptides. There is substantial evidence that amyloid beta is oxidized in vivo, which has led to the suggestion that oxidative stress is an important mediator of Alzheimer's disease. Metal-catalyzed oxidation can mimic in vivo oxidation of amyloid beta because the metal ion binds to the amino acid residues at the site of oxidation, which then deliver reactive oxygen species to that site. Based on electrospray mass spectrometry, it has been suggested that metal-catalyzed oxidation occurs on histidines-13 and -14. Unfortunately, the amyloid beta peptides provide complex spectra, so it is difficult to definitively characterize the sites of oxidation. Trypsin digestion of both native and oxidized amyloid beta1-16 and amyloid beta1-40 resulted in the formation of tryptic peptides corresponding to amyloid beta6-16, which could be separated by liquid chromatography (LC). Sites of oxidation were then unequivocally characterized as histidine-13 and histidine-14 by LC/tandem mass spectrometric (MS/MS) analysis of the tryptic peptides. The ability to analyze the specific amyloid beta6-16 tryptic fragments derived from full-length amyloid beta peptides will make it possible to determine whether oxidation in vivo occurs at specific histidine residues and/or at other amino acid residues such as methionine-35. Using methodology based on LC/MS/MS it will also be possible to analyze the relative amounts of oxidized peptides and native peptide in cerebrospinal fluid from patients with Alzheimer's disease as biomarkers of oxidative stress.

Alzheimer Disease↗

Quantitative analysis of amyloid beta peptides in cerebrospinal fluid of Alzheimer's disease patients by immunoaffinity purification and stable isotope dilution liquid chromatography/negative electrospray ionization tandem mass spectrometry.

The 40 and 42 amino-acid residue forms of amyloid beta (Abeta(1-40) and Abeta(1-42)) in cerebrospinal fluid (CSF) have been proposed as potential biomarkers of Alzheimer's disease (AD). Quantitative analyses of Abeta peptides in CSF have relied almost exclusively on the use of immunoassay-based assays such as the enzyme-linked immunosorbent assay (ELISA) procedure. However, due to the ability of the Abeta peptides to readily self-aggregate or bind to other proteins and glassware, such analyses are extremely challenging. Analyses are further complicated by the potential of the peptides to undergo post-translational modifications and the possibilities for cross-reaction in the ELISA assays with endogenous components of the CSF. An approach based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) has now been developed which overcomes these methodological issues. The key steps in implementing this new approach involved immunoaffinity purification coupled with the use of [15N]-labeled Abeta peptides as internal standards, a basic LC mobile phase, negative ion electrospray ionization, and a basic solvent for dissolving the peptides and washing the injection needle to prevent carryover of analytes during multiple injections on the LC/MS system. The validated method had limits of quantitation of 44 fmol/mL (200 pg/mL) for Abeta(1-42) and 92 fmol/mL (400 pg/mL) for Abeta(1-40). An excellent correlation was found between the LC/MS/MS assay and an ELISA assay for Abeta(1-42) in human CSF (r2 = 0.915), although less correlation was observed for Abeta(1-40) (r2 = 0.644). Mean CSF Abeta(1-42) concentrations for samples collected 2 weeks apart from a limited number of AD patients provided additional confidence in the reproducibility of the LC/MS/MS assay. Concentrations for duplicate samples from AD patients were slightly higher than most previously reported values (mean 1.06 +/- 0.25 ng/mL; n = 7). Abeta(1-40) concentrations in duplicate samples obtained from AD patients were also reproducible but were found to be slightly lower than most previously reported values (mean 6.36 +/- 3.07 ng/mL; n = 7). Consistent with literature reports, mean Abeta(1-42) concentrations were found to be lower in AD patients compared with the normal subjects (mean 1.49 +/- 0.59 ng/mL; n = 7), whereas there was no difference in Abeta(1-40) concentrations between AD patients and normal subjects (mean 5.88 +/- 3.03 ng/mL; n = 7). The accuracy and precision of the LC/MS assay mean that it will be a useful complement to existing ELISA assays for monitoring therapeutic interventions designed to modulate CSF Abeta(1-42) concentrations in individual AD patients. Moreover, the introduction of stable isotope labeled internal standards offers the potential to achieve a more rigorous account of the influence of methodological effects related to sample collection and processing.

Alzheimer Disease↗

The role of mass spectrometry in biomarker discovery and measurement.

Recent advances in the biological and analytical sciences have led to unprecedented interest in the discovery and quantitation of endogenous molecules that serve as indicators of drug safety, mechanism of action, efficacy, and disease state progression. By allowing for improved decision-making, these indicators, referred to as biomarkers, can dramatically improve the efficiency of drug discovery and development. Mass spectrometry has been a key part of biomarker discovery and evaluation owing to several important attributes, which include sensitive and selective detection, multi-analyte analysis, and the ability to provide structural information. Because of these capabilities, mass spectrometry has been widely deployed in search for new markers both through the analysis of large molecules (proteomics) and small molecules (metabonomics). In addition, mass spectrometry is increasingly being used to support quantitative measurement to assist in the evaluation and validation of biomarker leads. In this review, the dual role of mass spectrometry for biomarker discovery and measurement is explored for both large and small molecules by examining the key technologies and methods used along the continuum from drug discovery through clinical development.

Amino Acid Sequence↗

A review of nanoelectrospray ionization applications for drug metabolism and pharmacokinetics.

Although traditionally reserved for proteomic analysis, nanoESI has found increased use for small molecule applications related to drug metabolism/pharmacokinetics (DMPK). NanoESI, which refers to ESI performed at flow rates in the range of 200 to 1000 nL/min using smaller diameter emitters (10 to 100 microm id), produces smaller droplets than conventional ESI resulting in more efficient ionization. Benefits include greater sensitivity, enhanced dynamic range, and a reduced competition for ionization. These advantages may now be harnessed largely due to the introduction of a commercial system for automated nanoESI infusion. This development in turn has allowed ADME (absorption, distribution, metabolism, and excretion) scientists to consider novel approaches to mass spectrometric analysis without direct LC interfacing. While it is freely acknowledged that nanoESI infusion is not likely to supplant LC-MS as the primary analytical platform for ADME, nanoESI infusion has been successfully applied to both quantitative (bioanalysis) and qualitative (metabolite identification) applications. This review summarizes published applications of this technology and offers a perspective on where it fits best into the DMPK laboratory.

Animals↗

Validating regulatory-compliant wide dynamic range bioanalytical assays using chip-based nanoelectrospray tandem mass spectrometry.

Automated chip-based infusion nanoelectrospray ionization coupled to tandem mass spectrometry (nanoESI-MS/MS) was used to validate a bioanalytical assay conforming to United States Food and Drug Administration (FDA) regulatory guidelines and Good Laboratory Practices (GLP). Reboxetine was used as the analyte fortified in dog plasma along with an analog internal standard (IS). The best nanoESI response for reboxetine was observed with 90% acetonitrile (ACN)/water without any mobile phase modifiers. The analyte and IS were extracted from dog plasma samples by liquid-liquid extraction (LLE). The supernatant was concentrated to dryness and redissolved in 90% ACN/water for nanoESI. Selected reaction monitoring (SRM) data were collected for all samples to generate ion current profiles with a base width of approximately 20 s. Selectivity experiments showed no interferences in blank plasma samples. Interferences as a result of in-source collision-induced dissociation of metabolites were not an issue due to the previously documented metabolism of reboxetine. Matrix suppression was evaluated across multiple lots of dog plasma as well as over different animal species (rabbit, rat, mouse) and different anticoagulants (heparin, EDTA). Matrix suppression ranged from approximately 30-60% across the different lots, species etc.; however, in all instances, the analyte and the IS were suppressed by similar amounts, suggesting the similarity in ionization properties between the two. A three-batch validation was performed (each batch consisting of four different concentrations, six replicates of each concentration) and demonstrated inter-assay accuracy (% relative error; RE) of less than +/-8% and an inter-assay precision (% relative standard deviation; RSD) of less than 7%, thus meeting regulatory guidelines. A comparison of analyses by nanoESI-MS/MS and liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) showed that nanoESI-MS/MS had a greater slope for the calibration standard curve compared to LC/MS/MS, indicating greater sensitivity for the former technique. It is also noteworthy that the amount of sample infused during nanoESI-MS/MS was approximately 80-fold less compared to the amount of sample injected during LC/MS/MS. The absence of carryover (attributed to the lack of a common fluid path) in the nanoESI technique enabled the extension of the assay linear dynamic range to 500,000-fold, and the possibility of analyzing samples in a single batch without the need for re-analysis of samples with high concentrations. This technology offers the possibility for increased throughput for studies supporting drug development by providing fast data turnaround for assays conforming to regulatory guidelines and GLPs.

Animals↗

Development of an ion-pair reverse-phase liquid chromatographic/tandem mass spectrometry method for the determination of an 18-mer phosphorothioate oligonucleotide in mouse liver tissue.

A quantitative method for the determination of a partially modified, 2'-ribose alkoxy 18-mer phosphorothioate oligonucleotide, in liver tissue has been developed. A liquid:liquid extraction, ion-pair reverse phase chromatographic separation, and tandem mass spectrometry were used to achieve a quantitation range of 125 to 10,000 ng g(-1) mouse liver tissue. A total cycle time of 5 min was obtained while maintaining separation of three potential impurities. Separations were performed using a Discovery RP-Amide C16, 100 x 2 mm column packed with 5 microm particles. The separation was facilitated by the use of triethylamine (TEA) and hexafluoroisopropanol (HFIP) as ion-pair agents. The method has subsequently been used for the determination of other phosphorothioate oligonucleotides in support of discovery research.

Animals↗

Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry.

Quantitative bioanalysis by direct nanoelectrospray infusion coupled to tandem mass spectrometry has been achieved using an automated liquid sampler integrated with an array of microfabricated electrospray nozzles allowing rapid, serial sample introduction (1 min/ sample). Standard curves prepared in human plasma for verapamil (r2 = 0.999) and its metabolite norverapamil (r2 = 0.998) were linear over a range of 2.5-500 ng/ mL. Based on the observed precision and accuracy, a lower limit of quantitation of 5 ng/mL was assigned for both analytes. Sample preparation consisted of protein precipitation with an organic solvent containing the structural analogue gallopamil as an internal standard. Protein precipitation was selected both to maximize throughput and to test the robustness of direct nanoelectrospray infusion. Aliquots of supernatant (10 pL) were transferred to the back plane of the chip using disposable, conductive pipet tips for direct infusion at a flow rate of 300 nL/min. Electrospray ionization occurred from the etched nozzles (30-microm o.d.) on the front of the chip, initiated by a voltage applied to the liquid through the pipet tip. The chip was positioned near the API sampling orifice of a triple quadrupole mass spectrometer, which was operated in selected reaction monitoring mode. Results are presented that document the complete elimination of system carry-over, attributed to lack of a redundant fluid path. This technology offers potential advantages for MS-based screening applications in drug discovery by reducing the time for methods development and sample analysis.

Drug Monitoring↗

Characterization of dark liver pigment observed in rats after subchronic dosing of the beta3-adrenergic receptor agonist LY368842.

Dark liver pigmentation was observed in F344 rats in a subchronic toxicology study after daily dosing of LY368842 glycolate. In addition, green-colored urine was observed in some animals. To identify the source of the pigment and its potential for toxic consequences, the liver pigment was isolated from the liver tissue of rats. The resulting material was a dark brown to black powder that was insoluble in water, organic solvents, or a tissue-solubilizing agent. Several techniques, such as chemical degradation, HPLC, tandem mass spectrometry (LC/MS/MS), (1)H NMR, and matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS), were employed to characterize the dark liver pigment. Following oxidative degradation of the isolated pigment, degradation products related to LY368842 were identified or tentatively identified using LC/MS/MS. Two degradation products had the same protonated molecular ion at m/z 505, which is 30 amu higher than that of LY368842. The major m/z 505 product has been identified as the indole-2,3-dione oxidative product based on (1)H NMR data and confirmed by an authentic standard. In addition, monohydroxylated product was also identified in the degradation mixture. These degradation products were consistent with the metabolites found in vivo in rats. MALDI-MS analyses of liver and urine pigment both identified a product with a protonated molecular ion at m/z 977, suggesting formation of indirubin-like and indigo-like pigments. The results obtained suggest that the oxidative metabolites of LY368842 played a key role in the formation of the liver and urine pigments.

Adrenergic beta-3 Receptor Agonists↗

Effects of flow rate on high-throughput quantitative analysis of protein-precipitated plasma using liquid chromatography/tandem mass spectrometry.

The effects of flow rate and column length on analyte response (peak area and height), total cycle time, column backpressure, and elution volume are presented. Rapid chromatographic separations and tandem mass spectrometric (MS/MS) detection are applied to the supernatant of protein-precipitated plasma standards containing four compounds from a drug discovery screen. The plasma samples were injected onto three C-18 columns (2 x 10,2.1 x 30 and 2.1 x 50 mm) at flow rates of 0.25, 0.50, 1.00 and 1.50 mL/min. The plasma samples were detected using a Sciex API 3000 tandem mass spectrometer operated in the Turbo Ionspray mode. A post-column split was used to maintain a flow rate of 0.25 mL/min into the mass spectrometer source to avoid differences in nebulization efficiency. The data show that diluted protein-precipitated plasma supernatants show average matrix effects (i.e. suppression) of 60.0% (2 x 10 mm), 89.3% (2 x 30 mm), and 76.7% (2 x 50 mm) of expected response at 10 ng/mL. Average matrix effects of 70.2% (2 x 10 mm), 88.9% (2 x 30 mm), and 81.2% (2 x 50 mm) of expected response at 1000 ng/mL plasma. The data also show if peak widths remain relatively constant, analytes are less sensitive as flow rates are increased. These data are consistent with the concentration-dependent relationship of ionspray in the range of flow rates studied. The data show that, while analyte response decreased proportionately to increases in flow rate, the analysis cycle times did not decrease proportionately.

Blood Proteins↗

Recent advances in use of LC/MS/MS for quantitative high-throughput bioanalytical support of drug discovery.

LC/MS/MS based bioanalysis using atmospheric pressure ionization (API)-style interfaces has now been applied for over a decade. This technology, which initially found application for clinical bioanalysis, is now firmly established as the primary bioanalytical tool for ADME studies related to drug discovery and lead optimization (LO). This review focuses on recent advances in LC/MS/MS based bioanalysis in support of drug discovery and LO. The initial part of the article reviews the principal components of LC/MS/MS bioanalysis: sample preparation, chromatography, ionization and mass analysis. In each section, factors affecting high throughput bioanalysis are addressed. Because of the importance of on-line column switching methods to discovery bioanalysis, the section on sample preparation is divided into off-line and on-line approaches. In addition, the discussion of chromatography is limited to reversed phase liquid chromatography with emphasis given to the trend towards high-flow gradient elution techniques. The latter part of the review focuses on considerations for experimental design. In this section, pooling methods such as cassette dosing are discussed along with more highly integrated strategies linking bioanalysis with protocol generation and sample collection. The article concludes by briefly reviewing factors, which affect bioanalytical precision and accuracy, such as ion suppression, analyte stability and metabolite interference.