PubMed Health⌕ Search

PubMed · 15570573

Validating regulatory-compliant wide dynamic range bioanalytical assays using chip-based nanoelectrospray tandem mass spectrometry.

Abstract

Automated chip-based infusion nanoelectrospray ionization coupled to tandem mass spectrometry (nanoESI-MS/MS) was used to validate a bioanalytical assay conforming to United States Food and Drug Administration (FDA) regulatory guidelines and Good Laboratory Practices (GLP). Reboxetine was used as the analyte fortified in dog plasma along with an analog internal standard (IS). The best nanoESI response for reboxetine was observed with 90% acetonitrile (ACN)/water without any mobile phase modifiers. The analyte and IS were extracted from dog plasma samples by liquid-liquid extraction (LLE). The supernatant was concentrated to dryness and redissolved in 90% ACN/water for nanoESI. Selected reaction monitoring (SRM) data were collected for all samples to generate ion current profiles with a base width of approximately 20 s. Selectivity experiments showed no interferences in blank plasma samples. Interferences as a result of in-source collision-induced dissociation of metabolites were not an issue due to the previously documented metabolism of reboxetine. Matrix suppression was evaluated across multiple lots of dog plasma as well as over different animal species (rabbit, rat, mouse) and different anticoagulants (heparin, EDTA). Matrix suppression ranged from approximately 30-60% across the different lots, species etc.; however, in all instances, the analyte and the IS were suppressed by similar amounts, suggesting the similarity in ionization properties between the two. A three-batch validation was performed (each batch consisting of four different concentrations, six replicates of each concentration) and demonstrated inter-assay accuracy (% relative error; RE) of less than +/-8% and an inter-assay precision (% relative standard deviation; RSD) of less than 7%, thus meeting regulatory guidelines. A comparison of analyses by nanoESI-MS/MS and liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) showed that nanoESI-MS/MS had a greater slope for the calibration standard curve compared to LC/MS/MS, indicating greater sensitivity for the former technique. It is also noteworthy that the amount of sample infused during nanoESI-MS/MS was approximately 80-fold less compared to the amount of sample injected during LC/MS/MS. The absence of carryover (attributed to the lack of a common fluid path) in the nanoESI technique enabled the extension of the assay linear dynamic range to 500,000-fold, and the possibility of analyzing samples in a single batch without the need for re-analysis of samples with high concentrations. This technology offers the possibility for increased throughput for studies supporting drug development by providing fast data turnaround for assays conforming to regulatory guidelines and GLPs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Enaksha R Wickremsinhe, Bradley L Ackermann, Ajai K Chaudhary. 2005. Validating regulatory-compliant wide dynamic range bioanalytical assays using chip-based nanoelectrospray tandem mass spectrometry.. https://doi.org/10.1002/rcm.1747

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Protocol for Detecting and Sequencing Chikungunya Virus from Field-Collected Mosquitoes.

Arboviral diseases represent a major public health challenge, especially in tropical regions where environmental conditions may favor the proliferation and spread of mosquito vectors. Thus, early and accurate detection of chikungunya virus (CHIKV) in mosquito populations can be a valuable tool for effective surveillance of circulating variants and for identifying new viral introductions. Given the challenges of detecting arboviruses in field-captured mosquitoes, we describe an integrated workflow for CHIKV molecular detection and whole-genome sequencing. This protocol includes mosquito homogenization using a bead-based mechanical disruptor, RNA extraction using TRIzol reagent with minor modifications, molecular screening using CHIKV-specific RT-qPCR, and whole-genome amplification followed by sequencing on Illumina platforms. Despite the protocol being optimized for individual mosquitoes, it results in high-quality RNA suitable for both entomological surveillance and genomic analysis. As this protocol allows recovery of complete CHIKV genomes from mosquito specimens, it can serve as a basis for genomic epidemiology studies, enabling monitoring of viral diversity and lineage dynamics, and facilitating early detection of emerging variants to support timely and targeted public health interventions in endemic and at-risk regions.

Animals↗

Genomic Profiling of Chromatin State Using CUT&Tag.

Alterations in chromatin state, mediated through histone modifications and the incorporation of histone variants, are fundamental to establishing transcriptional networks and cell identity. Recent advances in low-input epigenome profiling methods, such as CUT&Tag and CUT&RUN, have enabled the study of chromatin states from very limited starting materials. In this chapter, we describe procedures for generating CUT&Tag libraries to profile histone modifications and histone variants in early-developing zebrafish embryos.

Animals↗

Relaxin-2: Shaping the Proteomic Landscape of Skeletal Muscle Physiology, Glucose Trafficking, and Mitochondrial Function in Rat.

Relaxin-2 is a hormone with robust beneficial effects on the heart and blood vessels and potential as a therapy for cardiovascular (CV) disease. Considering the interorgan communication between skeletal muscle and heart, and the relation between muscle quality/composition and CV events, we hypothesize that relaxin-2 may regulate skeletal muscle physiology and metabolism. We aim to evaluate the impact of relaxin-2 on the proteome of skeletal muscle from healthy Sprague-Dawley rats. Animals were treated with 0.4 mg/kg/day of serelaxin (recombinant form of human relaxin-2) or vehicle (PBS) for 2 weeks employing subcutaneous osmotic minipumps. Skeletal muscle protein identification and quantification were performed by LC-MS/MS using a Data-Independent Acquisition (DIA)-Sequential Window Acquisition of All Theoretical Fragment Ion Spectra (SWATH) method. SWATH/MS quantitative analysis identified that relaxin-2 significantly decreased 95 proteins and significantly increased 32 proteins in rat skeletal muscle when compared to control rats. From these, 34 proteins were associated with muscle function, myogenesis, muscle differentiation and/or regeneration, 20 are mitochondrial proteins (six from the complexes of the electron transport chain), and 10 proteins participate in glucose metabolism. Qualitative data-dependent workflow analysis identified 35 proteins exclusive to the skeletal muscle of the relaxin-2-treated group: eight proteins related to processes of skeletal muscle function (size, ion homeostasis or organization of caveolae structures and cytoskeleton) and myogenesis, and two proteins involved in muscle differentiation. Our work highlighted for the first time the role of relaxin-2 in crucial processes of muscle physiology and energetic metabolism, which could influence several processes involved in myopathy and CV.

Animals↗