PubMed Health⌕ Search

Biomedical subjects

Bruce S Edwards

Publications and source records attributed to Bruce S Edwards.

14 recordsLinked to original sources

Virtual and biomolecular screening converge on a selective agonist for GPR30.

Estrogen is a hormone critical in the development, normal physiology and pathophysiology of numerous human tissues. The effects of estrogen have traditionally been solely ascribed to estrogen receptor alpha (ERalpha) and more recently ERbeta, members of the soluble, nuclear ligand-activated family of transcription factors. We have recently shown that the seven-transmembrane G protein-coupled receptor GPR30 binds estrogen with high affinity and resides in the endoplasmic reticulum, where it activates multiple intracellular signaling pathways. To differentiate between the functions of ERalpha or ERbeta and GPR30, we used a combination of virtual and biomolecular screening to isolate compounds that selectively bind to GPR30. Here we describe the identification of the first GPR30-specific agonist, G-1 (1), capable of activating GPR30 in a complex environment of classical and new estrogen receptors. The development of compounds specific to estrogen receptor family members provides the opportunity to increase our understanding of these receptors and their contribution to estrogen biology.

Animals↗

Microsphere-based protease assays and screening application for lethal factor and factor Xa.

BACKGROUND: Proteases regulate many biological pathways in humans and are components of several bacterial toxins. Protease studies and development of protease inhibitors do not follow a single established methodology and are mostly protease specific. METHODS: We have created recombinant fusion proteins consisting of a biotinylated attachment sequence linked to a GFP via a protease cleavage site to develop a multiplexable microsphere-based protease assay system. Using the proteases lethal factor and factor Xa, we performed kinetic experiments to determine optimal conditions for inhibitor screens and detect known inhibitors using the HyperCyt flow cytometry system. RESULTS: We have demonstrated specific cleavage of lethal factor and factor Xa substrates, optimized screening conditions for these substrates, shown specific inhibition of the proteases, and demonstrated high throughput detection of these inhibitors. CONCLUSIONS: The assay developed here is adaptable to any site-specific protease, compatible with high throughput flow cytometry systems, and multiplexable. Coupled with flow cytometry, which provides continuous time resolution and intrinsic resolution of free vs. bound fluorophores, this assay will be useful for high throughput screening of protease inhibitors in general and could simplify assays designed to determine protease mechanism.

Antigens, Bacterial↗

Integration of virtual screening with high-throughput flow cytometry to identify novel small molecule formylpeptide receptor antagonists.

The formylpeptide receptor (FPR) family of G-protein-coupled receptors contributes to the localization and activation of tissue-damaging leukocytes at sites of chronic inflammation. We developed a FPR homology model and pharmacophore (based on the bovine rhodopsin crystal structure and known FPR ligands, respectively) for in silico screening of approximately 480,000 drug-like small molecules. A subset of 4324 compounds that matched the pharmacophore was then physically screened with the HyperCyt flow cytometry platform in high-throughput, no-wash assays that directly measure human FPR binding, with samples (each approximately 2500 cells in 2 microl) analyzed at 40/min. From 52 confirmed hits (1.2% hit rate), we identified 30 potential lead compounds (inhibition constant, Ki= 1-32 microM) representing nine distinct chemical families. Four compounds in one family were weak partial agonists. All others were antagonists. This virtual screening approach improved the physical screening hit rate by 12-fold (versus 0.1% hit-rate in a random compound collection), providing an efficient process for identifying small molecule antagonists.

Amino Acid Sequence↗

Post-high-throughput screening analysis: an empirical compound prioritization scheme.

An empirical scheme to evaluate and prioritize screening hits from high-throughput screening (HTS) is proposed. Negative scores are given when chemotypes found in the HTS hits are present in annotated databases such as MDDR and WOMBAT or for testing positive in toxicity-related experiments reported in TOXNET. Positive scores were given for higher measured biological activities, for testing negative in toxicity-related literature, and for good overlap when profiled against drug-related properties. Particular emphasis is placed on estimating aqueous solubility to prioritize in vivo experiments. This empirical scheme is given as an illustration to assist the decision-making process in selecting chemotypes and individual compounds for further experimentation, when confronted with multiple hits from high-throughput experiments. The decision-making process is discussed for a set of G-protein coupled receptor antagonists and validated on a literature example for dihydrofolate reductase inhibition.

Automation↗

High-throughput screening with HyperCyt flow cytometry to detect small molecule formylpeptide receptor ligands.

High-throughput flow cytometry (HTFC), enabled by faster automated sample processing, represents a promising high- content approach for compound library screening. HyperCyt is a recently developed automated HTFC analysis system by which cell samples are rapidly aspirated from microplate wells and delivered to the flow cytometer. The formylpeptide receptor (FPR) family of G protein-coupled receptors contributes to the localization and activation of tissue-damaging leukocytes at sites of chronic inflammation. Here, the authors describe development and application of an HTFC screening approach to detect potential anti-inflammatory compounds that block ligand binding to FPR. Using a homogeneous no-wash assay, samples were routinely processed at 1.5 s/well (approximately 2500 cells analyzed/sample), allowing a 96-well plate to be processed in less than 2.5 min. Assay sensitivity and accuracy were validated by detection of a previously documented active compound with relatively low FPR affinity (sulfinpyrazone, inhibition constant [K(i)]=14 microM) from among a collection of 880 compounds in the Prestwick Chemical Library. The HyperCyt system was therefore demonstrated to be a robust, sensitive, and highly quantitative method with which to screen lead compound libraries in a 96-well format.

Flow Cytometry↗

An investigation of liquid carryover and sample residual for a high-throughput flow cytometer sample delivery system.

The phenomenon of intersample contamination in air-segmented continuous-flow assays has been studied for many years, and new uses are being found for these sampling techniques every day. One application that has been developed recently employs a flow cytometer to conduct high-throughput screening assays of biological compounds. We have explored the sources of intersample contamination in the system and shown how methods developed previously can be applied to describe these phenomena. Using a simple model, we were able to accurately measure liquid film thickness in the sample tubing and demonstrate the effects of intersample contamination in a flow cytometer assay. Also, measures have been taken to reduce the level of intersample contamination in cytometric screening assays, helping to make the system a more viable tool for drug screening applications.

Capillaries↗

Real-time analysis of very late antigen-4 affinity modulation by shear.

Shear promotes endothelial recruitment of leukocytes, cell activation, and transmigration. Mechanical stress on cells caused by shear can induce a rapid integrin conformational change and activation, followed by an increase in binding to the extracellular matrix. The molecular mechanism of increased avidity is unknown. We have shown previously that the affinity of the alpha(4)beta(1) integrin, very late antigen-4 (VLA-4), measured with an LDV-containing small molecule, varies with cellular avidity, measured from cell disaggregation rates. In this study, we measured in real time affinity changes of VLA-4 in response to shear. The resulting affinity was comparable with the state mediated by receptor signaling and corresponded in time with intracellular Ca(2+) responses. Ca(2+) ionophores and N,N'-[1,2-ethanediyl-bis(oxy-2,1-phenylene)]bis[N-[2-[(acetyloxy)methoxy]-2-oxoethyl]]-, bis[(acetyloxy)methyl]ester demonstrate that the affinity regulation of VLA-4 in the presence of shear was related to Ca(2+) signaling. Pertussis toxin treatment implicates G(i) in an unknown pathway that connects shear, Ca(2+) elevation, VLA-4 affinity, and cell avidity.

Calcium↗

Conformational regulation of alpha 4 beta 1-integrin affinity by reducing agents. "Inside-out" signaling is independent of and additive to reduction-regulated integrin activation.

The alpha(4)beta(1)-integrin (very late antigen-4 (VLA-4), CD49d/CD29) is an adhesion receptor involved in the interaction of lymphocytes, dendritic cells, and stem cells with the extracellular matrix and endothelial cells. This and other integrins have the ability to regulate their affinity for ligands through a process termed "inside-out" signaling that affects cell adhesion avidity. Several mechanisms are known to regulate integrin affinity and conformation: conformational changes induced by separation of the C-terminal tails, divalent ions, and reducing agents. Recently, we described a fluorescent LDV-containing small molecule that was used to monitor VLA-4 affinity changes in live cells (Chigaev, A., Blenc, A. M., Braaten, J. V., Kumaraswamy, N., Kepley, C. L., Andrews, R. P., Oliver, J. M., Edwards, B. S., Prossnitz, E. R., Larson, R. S., and Sklar, L. A. (2001) J. Biol. Chem. 276, 48670-48678). Using the same molecule, we also developed a fluorescence resonance energy transfer-based assay to probe the "switchblade-like" opening of VLA-4 upon activation. Here, we investigated the effect of reducing agents on the affinity and conformational state of the VLA-4 integrin simultaneously with cell activation initiated by inside-out signaling through G protein-coupled receptors or Mn(2+) in live cells in real time. We found that reducing agents (dithiothreitol and 2,3-dimercapto-1-propanesulfonic acid) induced multiple states of high affinity of VLA-4, where the affinity change was accompanied by an extension of the integrin molecule. Bacitracin, an inhibitor of the reductive function of the plasma membrane, diminished the effect of dithiothreitol, but had no effect on inside-out signaling. Based on this result and differences in the kinetics of integrin activation, we conclude that conformational activation of VLA-4 by inside-out signaling is independent of and additive to reduction-regulated integrin activation.

Anti-Bacterial Agents↗

Flow cytometry for high-throughput, high-content screening.

Flow cytometry is a mature platform for quantitative multi-parameter measurement of cell fluorescence. Recent innovations allow up to 30-fold faster serial processing of bulk cell samples. Homogeneous discrimination of free and cell-bound fluorescent probe eliminates wash steps to streamline sample processing. Compound screening throughput may be further enhanced by multiplexing of assays on color-coded bead or cell suspension arrays and by integrating computational techniques to create smaller, focused compound libraries. Novel bead-based assay systems allow studies of real-time interactions between solubilized receptors, ligands and molecular signaling components that recapitulate and extend measurements in intact cells. These new developments, and its broad usage, position flow cytometry as an attractive analysis platform for high-throughput, high-content biological testing and drug discovery.

Automation↗

Techniques: GPCR assembly, pharmacology and screening by flow cytometry.

Flow cytometers are well known for their ability to analyze and sort cells at high rates based on physiological responses and expression of protein markers. The potential for flow cytometry in G-protein-coupled receptor (GPCR) research, however, is less well appreciated. Potential applications include: (i) the homogenous discrimination of free and bound ligands or proteins in both cellular and microsphere-based assays; and (ii) multiplexed ('suspension array') analysis of cell responses and protein-protein interactions. Innovative sample-handling systems also provide sub-second resolution of interaction kinetics and 1 second per well throughput of microliter-sized samples from multiwell plates. Flow cytometric methods using microspheres for analysis of GPCRs that interact with intracellular and extracellular binding partners such as ligands, G proteins and kinases have been established. These analyses can produce quantitative pharmacological data analogous to radioligand assays, and, in some cases, the probes can be integrated into the assembly as fluorescent fusion proteins.

Animals↗

High-throughput microfluidic mixing and multiparametric cell sorting for bioactive compound screening.

HyperCyt, an automated sample handling system for flow cytometry that uses air bubbles to separate samples sequentially introduced from multiwell plates by an autosampler. In a previously documented HyperCyt configuration, air bubble separated compounds in one sample line and a continuous stream of cells in another are mixed in-line for serial flow cytometric cell response analysis. To expand capabilities for high-throughput bioactive compound screening, the authors investigated using this system configuration in combination with automated cell sorting. Peptide ligands were sampled from a 96-well plate, mixed in-line with fluo-4-loaded, formyl peptide receptor-transfected U937 cells, and screened at a rate of 3 peptide reactions per minute with approximately 10,000 cells analyzed per reaction. Cell Ca(2+) responses were detected to as little as 10(-11) M peptide with no detectable carryover between samples at up to 10(-7) M peptide. After expansion in culture, cells sort-purified from the 10% highest responders exhibited enhanced sensitivity and more sustained responses to peptide. Thus, a highly responsive cell subset was isolated under high-throughput mixing and sorting conditions in which response detection capability spanned a 1000-fold range of peptide concentration. With single-cell readout systems for protein expression libraries, this technology offers the promise of screening millions of discrete compound interactions per day.

Calcium↗

Alpha4beta1 integrin affinity changes govern cell adhesion.

Integrin alpha4beta1 is a receptor for vascular cell adhesion molecule-1 and fibronectin. It is important in lymphopoiesis, inflammatory recruitment of leukocytes, and other situations that require cell adhesion to the vascular endothelium. The avidity of the cells expressing alpha4beta1 integrin can be rapidly changed by chemokines and chemoattractants. Different mechanisms, including changes in the number of interacting molecules due to the alteration of the receptor topology or changes in the affinity of the individual bonds, have been proposed to explain the nature of these fast changes in avidity. Recently, we described a fluorescent LDV-containing small molecule, which we used to monitor the affinity changes on live cells in real time (Chigaev, A., Blenc, A. M., Braaten, J. V., Kumaraswamy, N., Kepley, C. L., Andrews, R. P., Oliver, J. M., Edwards, B. S., Prossnitz, E. R., Larson, R. S. et al. (2001) J. Biol. Chem. 276, 48670-48678). Here we show that the affinity of the small molecule probe as well as the native ligand vascular cell adhesion molecule-1 varies in parallel when the integrin is modulated with divalent cations and that the affinity modulation leads to the changes in cell avidity. Using formyl peptide receptor-transfected U937 cells, we further show that the time course of avidity changes in response to the receptor activation coincides with the time course of the affinity changes. Taken together, these data are consistent with the idea that affinity regulation is a major factor that governs the avidity of cell adhesion mediated by the alpha4 integrin.

Animals↗

High-throughput flow cytometry: validation in microvolume bioassays.

BACKGROUND: We recently reported an automated sample handling system, designated HyperCyt, by which samples are aspirated from microplate wells and delivered to the flow cytometer for analysis at rates approaching 100 samples per minute. In this approach, an autosampler and peristaltic pump introduce samples into a tubing line that directly connects to the flow cytometer. Air bubbles are inserted between samples to prevent sample dispersion. In the present work, we compare results of HyperCyt with those of conventional manual flow cytometric analysis in representative flow cytometric bioassays and describe a cell suspension method in which HyperCyt exploits the use of microvolume wells. METHODS: Human eosinophils and neutrophils were treated with trypsin to generate a wide (>25-fold) range of membrane P-selectin glycoprotein ligand-1 (PSGL-1) expression and then stained with fluorescent anti-PSGL-1 antibodies. Human peripheral blood mononuclear cells were stained with fluorescein isothiocyanate- and phycoerythrin-conjugated monoclonal antibodies for multiparameter immunophenotype analysis. U937 cells labeled with PKH62GL were used to assess cell settling in microplate wells. RESULTS: Differences in PSGL-1 expression levels were detected by HyperCyt autosampling of leukocytes from 96-well plates at an analysis rate of approximately 1.5 s/well. HyperCyt measurements linearly correlated with parallel manual measurements (r(2) = 0.98). Lymphocyte subpopulations were accurately distinguished and reproducibly quantified in multiparameter immunophenotyping assays performed over a range of HyperCyt analysis rates (1.4-5.5 s/sample). When assay volumes were reduced to 10 microl/well in 60-well Terasaki plates, cells could be maintained in uniform suspension for up to 30 min by periodically inverting plates on a rotating carousel before HyperCyt analysis. HyperCyt analysis of five fluorescence-level Cyto-Plex beads sampled from Terasaki plate microwells at 2.5 s/well produced highly reproducible results over a wide range of input bead concentrations (from 7 x 10(5) to 20 x 10(6) beads/ml) that linearly correlated with manual analysis results. CONCLUSIONS: The HyperCyt autosampling system enabled a 10-fold or greater increase in sample throughput compared with conventional manual flow cytometric sample analysis, with comparable analysis results. Assays were performed efficiently in 10-microl volumes to enable significant reagent cost savings, use of quantity-limited reagents at otherwise prohibitive concentrations, and maintenance of uniform suspensions of cells for prolonged periods.

Biological Assay↗

Flow cytometric analysis of ligand-receptor interactions and molecular assemblies.

Flow cytometers make homogeneous real-time measurements of ligand-receptor interactions and, simultaneously, the physiological responses of cells. Their multiparameter capabilities are also useful in resolving multicomponent assemblies or in developing multiplexed assays. Recent advances suggest that these approaches can be extended in several important ways. Sample delivery in the millisecond time domain is applicable to the analysis of complex binding kinetics and reaction mechanisms. The homogeneous discrimination of free components and particle-based assemblies can be extended into the micromolar concentration range. Measurements can be made of molecular assemblies among proteins, DNA, RNA, lipids, and carbohydrates on beads. The topography and assembly of components within cells can be evaluated with resonance energy transfer. Temperature dependence can be evaluated with Peltier temperature control. Many assembly endpoints can be assessed through new tools for high-throughput flow cytometry using plate-based assay formats and small volume samples.

Animals↗