BACKGROUND: We recently reported an automated sample handling system, designated HyperCyt, by which samples are aspirated from microplate wells and delivered to the flow cytometer for analysis at rates approaching 100 samples per minute. In this approach, an autosampler and peristaltic pump introduce samples into a tubing line that directly connects to the flow cytometer. Air bubbles are inserted between samples to prevent sample dispersion. In the present work, we compare results of HyperCyt with those of conventional manual flow cytometric analysis in representative flow cytometric bioassays and describe a cell suspension method in which HyperCyt exploits the use of microvolume wells. METHODS: Human eosinophils and neutrophils were treated with trypsin to generate a wide (>25-fold) range of membrane P-selectin glycoprotein ligand-1 (PSGL-1) expression and then stained with fluorescent anti-PSGL-1 antibodies. Human peripheral blood mononuclear cells were stained with fluorescein isothiocyanate- and phycoerythrin-conjugated monoclonal antibodies for multiparameter immunophenotype analysis. U937 cells labeled with PKH62GL were used to assess cell settling in microplate wells. RESULTS: Differences in PSGL-1 expression levels were detected by HyperCyt autosampling of leukocytes from 96-well plates at an analysis rate of approximately 1.5 s/well. HyperCyt measurements linearly correlated with parallel manual measurements (r(2) = 0.98). Lymphocyte subpopulations were accurately distinguished and reproducibly quantified in multiparameter immunophenotyping assays performed over a range of HyperCyt analysis rates (1.4-5.5 s/sample). When assay volumes were reduced to 10 microl/well in 60-well Terasaki plates, cells could be maintained in uniform suspension for up to 30 min by periodically inverting plates on a rotating carousel before HyperCyt analysis. HyperCyt analysis of five fluorescence-level Cyto-Plex beads sampled from Terasaki plate microwells at 2.5 s/well produced highly reproducible results over a wide range of input bead concentrations (from 7 x 10(5) to 20 x 10(6) beads/ml) that linearly correlated with manual analysis results. CONCLUSIONS: The HyperCyt autosampling system enabled a 10-fold or greater increase in sample throughput compared with conventional manual flow cytometric sample analysis, with comparable analysis results. Assays were performed efficiently in 10-microl volumes to enable significant reagent cost savings, use of quantity-limited reagents at otherwise prohibitive concentrations, and maintenance of uniform suspensions of cells for prolonged periods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sergio Ramirez, Charity T Aiken, Brett Andrzejewski, Larry A Sklar, Bruce S Edwards. 2003. High-throughput flow cytometry: validation in microvolume bioassays.. https://doi.org/10.1002/cyto.a.10035

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The statistical performance of an MCF-7 cell culture assay evaluated using generalized linear mixed models and a score test.

Biological assays often utilize experimental designs where observations are replicated at multiple levels, and where each level represents a separate component of the assay's overall variance. Statistical analysis of such data usually ignores these design effects, whereas more sophisticated methods would improve the statistical power of assays. This report evaluates the statistical performance of an in vitro MCF-7 cell proliferation assay (E-SCREEN) by identifying the optimal generalized linear mixed model (GLMM) that accurately represents the assay's experimental design and variance components. Our statistical assessment found that 17beta-oestradiol cell culture assay data were best modelled with a GLMM configured with a reciprocal link function, a gamma error distribution, and three sources of design variation: plate-to-plate; well-to-well, and the interaction between plate-to-plate variation and dose. The gamma-distributed random error of the assay was estimated to have a coefficient of variation (COV) = 3.2 per cent, and a variance component score test described by X. Lin found that each of the three variance components were statistically significant. The optimal GLMM also confirmed the estrogenicity of five weakly oestrogenic polychlorinated biphenyls (PCBs 17, 49, 66, 74, and 128). Based on information criteria, the optimal gamma GLMM consistently out-performed equivalent naive normal and log-normal linear models, both with and without random effects terms. Because the gamma GLMM was by far the best model on conceptual and empirical grounds, and requires only trivially more effort to use, we encourage its use and suggest that naive models be avoided when possible.

Biological Assay↗

Reactivation of Kaposi's sarcoma-associated herpesvirus by natural products from Kaposi's sarcoma endemic regions.

Kaposi's sarcoma (KS) and its causative agent, Kaposi's sarcoma associated herpesvirus (KSHV/HHV-8), a gamma2 herpesvirus, have distinctive geographical distributions that are largely unexplained. We propose the "oncoweed" hypothesis to explain these differences, namely that environmental cofactors present in KS endemic regions cause frequent reactivation of KSHV in infected subjects, leading to increased viral shedding and transmission leading to increased prevalence of KSHV infection as well as high viral load levels and antibody titers. Reactivation also plays a role in the pathogenesis of KSHV-associated malignancies. To test this hypothesis, we employed an in vitro KSHV reactivation assay that measured increases in KSHV viral load in KSHV infected primary effusion lymphoma (PEL) cells and screened aqueous natural product extracts from KS endemic regions. Of 4,842 extracts from 38 countries, 184 (5%) caused KSHV reactivation. Extracts that caused reactivation came from a wide variety of plant families, and extracts from Africa, where KSHV is highly prevalent, caused the greatest level of reactivation. Time course experiments were performed using 28 extracts that caused the highest levels of reactivation. The specificity of the effects on viral replication was examined using transcriptional profiling of all viral mRNAs. The array data indicated that the natural extracts caused an ordered cascade of lytic replication similar to that seen after induction with synthetic activators. These in vitro data provide support for the "oncoweed" hypothesis by demonstrating basic biological plausibility.

Biological Assay↗

Techniques for radiation measurements: microdosimetry and dosimetry.

Experimental microdosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nanometer, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental microdosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with microdosimetric techniques will be shown and the particular benefits of using microdosimetric methods for dosimetry illustrated.

Biological Assay↗