PubMed Health⌕ Search

Biomedical subjects

C Duvivier

Publications and source records attributed to C Duvivier.

At least 55 records · Page 3Linked to original sources

Influence of chronic hypoxia on salbutamol tissular concentrations and on respiratory resistance in anesthetized rabbits.

Salbutamol is a potent beta 2-adrenoceptor agonist given to patients with bronchial asthma who are frequently hypoxemic. The aims of this study were to document the influence of chronic hypoxia on salbutamol tissue concentrations and on salbutamol effect on total respiratory resistance. To this purpose, salbutamol (60 micrograms/kg) was administered intravenously to four groups of six rabbits exposed to four experimental conditions: (1) control rabbits breathing air, (2) histamine-induced bronchoconstriction in rabbits breathing air, (3) animals with chronic hypoxia, (4) histamine-induced bronchoconstriction in animals with chronic hypoxia. The area under salbutamol plasma concentration time curve (0 to 45 min) was not affected by these experimental conditions. Compared with control rabbits breathing air, following histamine-induced bronchoconstriction, salbutamol concentrations rose by 40 to 50% in lung and heart (p < 0.05). Hypoxia did not affect salbutamol distribution in these organs; however, in hypoxic animals, histamine-induced bronchoconstriction increased salbutamol concentrations only in the heart (p < 0.05), without affecting those in the lung. Compared with rabbits breathing air and with histamine-induced bronchoconstriction, the effect of salbutamol was reduced in rabbits under chronic hypoxia and histamine-induced bronchoconstriction (p < 0.05). We conclude that chronic hypoxia reduces salbutamol effect on pulmonary resistance, possibly by decreasing salbutamol lung concentrations.

Airway Resistance↗

Expiratory capnography in asthma: evaluation of various shape indices.

The shape of the capnogram is modified by airway obstruction, and the evaluation of this deformation, using measurable indices, could allow an indirect measurement of bronchial patency. A previous study undertaken in asthmatic subjects showed a good correlation between a capnographic index (end-tidal slope) and a spirometric parameter (forced expiratory volume in one second as a percentage of predicted (FEV1 %pred)) and suggested the study of other indices. The correlations between capnographic and spirometric indices were measured in 10 healthy subjects and 30 asthmatic patients. The usefulness of eight descriptive indices, analysing the successive phases of the capnogram, was assessed by measuring their reproducibility and their sensitivity to airway obstruction. The intraindividual and interindividual variabilities (Vi and VI) and the noise/signal ratio (Vi/VI) were measured by comparing the results of two successive capnographic measurements in 14 asthmatic subjects. The results show an increasing noise/signal ratio along the expiration (between 23 and 62%). Significant correlations between spirometry and capnography were found with all indices, but the strongest were observed with indices analysing the intermediate phase of the capnogram, that is the angle between the ascending phase (E2) and the alveolar plateau (E3). The correlations show that the analysis of the capnogram's shape is a quantitative method for evaluating the severity of bronchospasm. This ability, added to specific advantages (noninvasiveness, effort-independency, measurements during tidal breathing) opens new fields of application to capnography, such as measurement of bronchospasm in children and computerized monitoring of asthma.

Adult↗

Input respiratory impedance to estimate airway hyperreactivity in children: standard method versus head generator.

We previously found that a significant underestimation of respiratory mechanical impedance (Zrs) at high frequency may result from the upper airway artefact in children, when pressure is directly varied at the mouth. To determine the importance of this artefact in estimating lung response to bronchomotor agents with the forced oscillation technique, input respiratory mechanical impedance was measured using 6-32 Hz pseudorandom pressure oscillations applied directly to the mouth (standard generator (SG)) and around the subject's head (head generator (HG)) in 35 children aged 2.5-13 yrs. Changes in resistance were generally larger with HG than SG. The mean +/- SEM changes in resistance of the respiratory system (Rrs) at 20 Hz induced by acetylcholine or allergen challenge were 15 +/- 4% for SG and 67 +/- 12% for HG, and changes induced by bronchodilators were -25 +/- 2% for SG, and -46 +/- 4% for HG (p < 0.01). Challenge induced negative frequency dependence of Rrs with SG and positive frequency dependence with HG. There was significant increase in inertance after salbutamol with SG, but no significant change occurred with HG. With both methods, respiratory compliance decreased significantly after challenge. Computer simulations showed that the difference in change in Rrs induced by airway challenge with HG and SG could be explained by the effect of the upper airway wall impedance (Zuaw). Zuaw could also account for the change in inertance and compliance observed with SG, but not for the change in compliance with HG. The latter could be reproduced by simulating unequal distribution of mechanical time constants within the lung, increased peripheral lung resistance with compliant central airways.(ABSTRACT TRUNCATED AT 250 WORDS)

Airway Resistance↗

Fourier analysis versus multiple linear regression to analyse pressure-flow data during artificial ventilation.

Respiratory resistance (Rrs) and elastance (Ers) are commonly measured in artificially-ventilated patients or animals by multiple linear regression of airway opening pressure (Pao) versus flow (V') and volume (V), according to the first order model: Pao = P0 + Ers.V + Rrs.V', where P0 is the static recoil pressure at end-expiration. An alternative way to obtain Rrs and Ers is to derive them from the Fourier coefficients of Pao and V' at the breathing frequency. A potential advantage of the second approach over the first is that it should be insensitive to a zero offset on V' and to the corresponding volume drift. The two methods were assessed comparatively in six tracheotomized, paralysed and artificially ventilated rabbits with and without adding to V' an offset equal to 5% of the mean unsigned flow. The 5% flow offset did not modify the results of Fourier analysis, but increased Rrs and Ers from linear regression by 15.8 +/- 4.6% and 4.55 +/- 0.64%, respectively. Without additional offset, differences between the two methods averaged 30.2 +/- 14.0% for Rrs and 9.3 +/- 6.2% for Ers. The differences almost completely disappeared (2.47 and 0.61%, respectively) when the flow signal was zero-corrected using the assumption that inspired and expired volumes were the same. After induced bronchoconstriction, however, Ers was still slightly larger by linear regression than by Fourier analysis, which may result from nonlinearities and/or frequency dependence of the parameters. We conclude that the regression method requires zero flow correction and that Fourier analysis is an attractive alternative.

Algorithms↗

Cytomegalovirus multifocal neuropathy in AIDS: analysis of 15 consecutive cases.

A severe multifocal neuropathy caused by cytomegalovirus (CMV-MN) can occur in the late stage of human immunodeficiency virus (HIV) infection. In a retrospective study, we identified 15 consecutive HIV-positive patients with a diagnosis of CMV-MN based on (1) markedly asymmetric neuropathy, (2) fewer than 100 CD4+ cells per mm3, (3) exclusion of other causes of neuropathy, and (4) characteristic CMV cytopathic changes on neuromuscular biopsy (2 patients), positive CSF culture for CMV (2 patients), or clinical improvement on anti-CMV therapy given for concurrent extraneurologic CMV disease (8 patients) or neuropathy (3 patients). All patients were men and had severe immunosuppression (mean CD4+ cell count, 18 per mm3). The initial symptoms were numbness and painful paresthesias showing a patchy, multifocal distribution. After a mean of 11 weeks (range, 1 to 10 months), the patients developed moderate or severe sensorimotor asymmetric neuropathy. Extraneurologic CMV infection occurred in 10 patients before diagnosis. Electrophysiologic studies showed axonal neuropathy and CMV DNA was present in CSF by the polymerase chain reaction (PCR) technique in 90% of patients tested. Fourteen patients showed a marked improvement 1 to 4 weeks after starting ganciclovir or foscarnet therapy. During follow-up on maintenance therapy (13 patients), the neuropathy relapsed in three patients and probable or confirmed CMV encephalitis occurred in five. Twelve patients died during follow-up, at a mean interval of 9.5 months after their first symptoms. These results extend the clinical spectrum of CMV-MN and show that PCR detection of CMV DNA in CSF may be a useful diagnostic marker.

Acquired Immunodeficiency Syndrome↗

Measurement of respiratory impedance by forced oscillation: comparison of the standard and head generator methods.

Physiological and clinical studies have shown that the standard method of measuring respiratory impedance by forced oscillation leads to less efficient control of the upper airway shunt effect than the head generator method. To test the effects of these two techniques in epidemiological studies, we compared, in a sample of 73 French agricultural workers, the values obtained with each method for five forced oscillation parameters: resistance, frequency dependence of resistance, inertance, compliance and resonant frequency. For these comparisons, subjects were classified according to four respiratory status factors: smoking status, cough, expectoration and airway obstruction assessed from the maximum expiratory flow volume curve. Logistic regression models using the set of four forced oscillation parameters (excluding resonant frequency, which is derived from compliance and inertance) were then used to analyse the ability of each method to classify the subjects in each group. Significant differences between the two methods were observed for the mean values obtained for all five parameters. However, when each parameter was considered separately, the correlations between the values for each method were significant. Each method possessed the necessary ability to separate subjects into our group classification, but the significant relationships were not always found for the same parameters. Finally, logistic regression models showed that the two methods led to almost the same classification of the subjects. According to our results, the standard method of applying forced oscillation at the mouth seems an acceptable device for measuring respiratory impedance for epidemiological purposes.

Airway Obstruction↗

Human cytomegalovirus (HCMV) late-mRNA detection in peripheral blood of AIDS patients: diagnostic value for HCMV disease compared with those of viral culture and HCMV DNA detection.

A reverse transcriptase polymerase chain reaction (RT-PCR) was used to detect a human cytomegalovirus (HCMV) late mRNA in peripheral blood leukocytes (PBL) of 102 human immunodeficiency virus-infected individuals. The clinical value of this new technique for the diagnosis of acute HCMV disease was evaluated in comparison with viral culture and direct amplification of viral DNA (PCR). The sensitivity of the RT-PCR was slightly lower than that of the two other methods, but its specificity was 94%, compared to 55 and 32% for culture and PCR, respectively. Transcription of this late mRNA is linked to viral replication, and its detection in PBL confirms that these cells can support a complete viral cycle. The relationship between complete replicative cycles and HCMV disease makes RT-PCR a useful clinical tool.

AIDS-Related Opportunistic Infections↗

Optimal frequency range to analyze respiratory transfer impedance with six-element model.

The aim of this investigation was to assess the optimal frequency range for analyzing respiratory transfer impedance (Ztr) in terms of tissue and airway mechanical properties using the six-element model of DuBois et al. (J. Appl. Physiol. 8:587-594, 1956). Ztr was measured in nine healthy subjects from 2 to 64 Hz by studying the relationship between airway flow and pseudorandom pressure oscillations applied around the chest. The measurements were performed with and without two mechanical loads placed at the mouth: an added inertance of 1.4 Pa.s2.l-1 and an added resistance of 1.65 hPa.s.l-1. The data were corrected for the shunt effect of upper airway walls. The changes in Ztr induced by the loads were very consistent up to 56 Hz with the T-network topology assumed in DuBois's model; the agreement deteriorated at higher frequencies, presumably due to the difficulty of obtaining a homogeneous pressure field around the chest. The fit of the model to the data also worsened sharply at above 56 Hz. In the 2- to 56-Hz frequency range, similar values of the tissue and airway coefficients were obtained with and without the loads. In that frequency range the confidence intervals of the coefficients were better than 10%. We conclude that DuBois's model is valid from 2 to 56 Hz in healthy subjects and allows accurate partitioning of airways and tissue properties. In addition, we present evidence that the upper airway shunt negligibly influences Ztr data and the derived coefficients provided airway flow is measured with a low-impedance pneumotachograph.

Adult↗

Respiratory mechanics studied by forced oscillations during artificial ventilation.

Potential advantages of the forced oscillation technique over other methods for monitoring total respiratory mechanics during artificial ventilation are that it does not require patient relaxation, and that additional information may be derived from the frequency dependence of the real (Re) and imaginary (Im) parts of respiratory impedance. We wanted to assess feasibility and usefulness of the forced oscillation technique in this setting and therefore used the approach in 17 intubated patients, mechanically ventilated for acute respiratory failure. Sinusoidal pressure oscillations at 5, 10 and 20 Hz were applied at the airway opening, using a specially devised loudspeaker-type generator placed in parallel with the ventilator. Real and imaginary parts were corrected for the flow-dependent impedance of the endotracheal tube; they usually exhibited large variations during the respiratory cycle, and were computed separately for the inspiratory and expiratory phases. In many instances the real part was larger during inspiration, probably due to the larger respiratory flow, and decreased with increasing frequency. The imaginary part of respiratory impedance usually increased with increasing frequency during expiration, as expected for a predominately elastic system, but often varied little, or even decreased, with increasing frequency during inspiration. In most patients, the data were inconsistent with the usual resistance-inertance-compliance model. A much better fit was obtained with a model featuring central airways and a peripheral pathway in parallel with bronchial compliance. The results obtained with the latter model suggest that dynamic airway compression occurred during passive expiration in a number of patients. We conclude that the use of forced oscillation is relatively easy to implement during mechanical ventilation, that it allows the study of respiratory mechanics at various points in the respiratory cycle, and may help in detecting expiratory flow limitation.

Adult↗

[Comparison of bronchodilator effects and site of action of fenoterol and ipratropium in chronic obstructive bronchitis].

There is no lack of data in the literature reporting on the efficacy of different bronchodilators. However, the discussion concerning the superiority of one bronchodilator over another in patients with chronic bronchitis and airflow obstruction is, and remains, a controversial subject. This has been particularly so since the perfection of synthetic anticholinergics delivered by inhalation without any side-effects. The aim of the present work is to compare the bronchodilator effects of a sympathomimetic, fenoterol (Berotec), and of an anticholinergic, ipratropium bromide (Atrovent), compared to a placebo in twelve unselected chronic bronchitics who had airflow obstruction and were in a stable clinical state. The bronchodilator effect of the two drugs was judged at the same time by variations on forced expired volume (FEV1) which was taken as a reference value, and of the maximum mid-expiratory flow (MEF) measured by spirography and also the variations of pulmonary resistance (delta Rrs) measured by the forced oscillatory method. The comparison of these indices enables the site of action of these agents to be specified. The dose response curve and the duration of action over six hours was assessed for each of the three agents. These were administered in succession and at random over three days by inhalation using an inhalation chamber. All the patients who were included were capable of producing a bronchodilator response but two of them responded only to one agent. The change in the FEV1 was comparable with the two active products. The change in MEF (an index of peripheral airways) was significantly greater following ipratropium.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Inhalation↗

Skeletal muscle toxoplasmosis in patients with acquired immunodeficiency syndrome: a clinical and pathological study.

The present article describes the clinical and pathological findings in 5 human immunodeficiency virus (HIV)-infected patients with muscle toxoplasmosis. The patients had marked lymphopenia (5/5), with less than five CD4+ cells/mm3 (3/3), when they developed fever (5/5), and multiorgan failure (5/5), including diffuse encephalitis, pneumonia, pancytopenia, and myopathy. Muscle involvement included weakness and wasting (4/5), myalgias (3/5), and high serum creatine kinase levels (3/3). Serology for toxoplasmosis showed high IgG titers in 3 patients (3/4). Anti-Toxoplasma therapy resulted in complete recovery in 2 patients. Muscle toxoplasmosis was detected by biopsy (3/5) or postmortem evaluation (2/5), and was identified using immunocytochemistry and electron microscopy. Toxoplasma cysts were detected in 0.5 to 4% of muscle fibers close to or remote from necrotic fibers and inflammatory infiltrates. Muscle fibers strongly expressed the major histocompatibility complex class I antigen (2/2) as in polymyositis. We suggest that Toxoplasma gondii should be sought by muscle biopsy in patients who have acquired immunodeficiency syndrome with fever, encephalitis, multiorgan dysfunction, and elevated serum creatine kinase levels of obscure origin.

Acquired Immunodeficiency Syndrome↗

Mechanical properties of the upper airway wall in children and their influence on respiratory impedance measurements.

The upper airway wall impedance (Zuaw) may be responsible for a large artifact in the measurement of respiratory system impedance (Zrs) in children. In 17 normal children aged 3.5-13 years Zuaw and Zrs were estimated by varying transrespiratory pressure directly at the mouth (conventional method: Z1) and around the subject's head (head generator method: Z2) from 4 to 32 Hz. Zrs and Zuaw were calculated from Z1 = Zrs.Zuaw/(Zrs+Zuaw) and Z2 = Zrs (1 + Zp/Zuaw), where Zp is the impedance of the pneumotachograph. From the real and imaginary part of Z1, Z2, Zrs, and Zuaw, the corresponding resistance, inertance, compliance and resonant frequency were calculated assuming simple RIC models. No significant difference was found between the mean +/- SE of parameters derived from Zrs (respectively, 6.8 +/- 0.4 cmH2O.L-1.s, 0.034 +/- 0.001 cmH2O.L-1.s2, 10.4 +/- 0.8 m.cmH2O-1, 9.1 +/- 0.3 Hz) and Z2 (6.8 +/- 0.4 cmH2O.L-1.s, 0.038 +/- 0.002 cmH2O.L-1.s2, 10.7 +/- 0.7 ml.cmH2O-1, 8.7 +/- 0.4 Hz). All but the compliance, derived from Z1 were significantly different (P less than 0.01) from those derived from Zrs (5.3 +/- 0.3 cmH2O.L-1.s, 0.008 +/- 0.001 cmH2O.L-1.s2, 11.9 +/- 1.2 ml.cmH2O-1, and 20.3 +/- 1.6 Hz). Respiratory resistance and compliance correlated significantly with height (r = -0.56 and 0.86, respectively), in contrast to upper airway wall resistance (Ruaw) and compliance (Cuaw). Ruaw (8.6 +/- 0.8 cmH2O.L-1.s), Cuaw (1.2 +/- 0.2 m.cmH2O-1), and upper airway wall inertance (0.030 +/- 0.004 cmH2O.L-1.s2) were close to those obtained by direct measurements in adults. The mechanical properties of the upper airway wall are responsible for a significant error in the measurement of Zrs by the conventional method in normal children. Most of the artifact may be corrected for by applying pressure around the child's head.

Biomechanical Phenomena↗

Evaluation of the multiple linear regression method to monitor respiratory mechanics in ventilated neonates and young children.

A potentially useful method to monitor respiratory mechanics in artificially ventilated patients consists of analyzing the relationship between tracheal pressure (P), lung volume (V), and gas flow (V) by multiple linear regression (MLR) using a suitable model. Contrary to other methods, it does not require any particular flow waveform and, therefore, may be used with any ventilator. This approach was evaluated in three neonates and seven young children admitted into an intensive care unit for respiratory disorders of various etiologies. P and V were measured and digitized at a sampling rate of 40 Hz for periods of 20-48 s. After correction of P for the non-linear resistance of the endotracheal tube, the data were first analyzed with the usual linear monoalveolar model: P = PO + E.V + R.V where E and R are total respiratory elastance and resistance, and PO is the static recoil pressure at end-expiration. A good fit of the model to the data was seen in five of ten children. PO, E, and R were reproducible within cycles, and consistent with the patient's age and condition; the data obtained with two ventilatory modes were highly correlated. In the five instances in which the simple model did not fit the data well, they were reanalyzed with more sophisticated models allowing for mechanical non-homogeneity or for non-linearity of R or E. While several models substantially improved the fit, physiologically meaningful results were only obtained when R was allowed to change with lung volume. We conclude that the MLR method is adequate to monitor respiratory mechanics, even when the usual model is inadequate.

Airway Resistance↗

Changes in inspired gas composition and experimental bronchospasm in the rabbit.

In clinical practice, bronchospasm could be facilitated by hypoxia and by hypercapnia. In this study we assessed the influence of breathing a hypoxic (FIO2 = 0.10) or a hypercapnic (FICO2 = 0.08) gas mixture on the response to nebulized histamine (2% solution for 5 min) in anesthetized, tracheotomized, paralyzed and mechanically ventilated rabbits. Total respiratory resistance (Rrs) and elastance (Ers) were derived by least-square analysis from the relationship between tracheal pressure and flow. Control values of Rrs were larger during hypoxia and hypercapnia than in air while the values of Ers were similar. The absolute change in Rrs after histamine was similar in air and hypoxia, and larger in hypercapnia. The relative change, however, was smaller in hypoxia than in the two other conditions. Ers was also substantially increased by histamine and, contrary to Rrs, remained high 60 min after the aerosol. The results suggest: (1) that both hypoxia and hypercapnia increase airway resistance but do not change tissue properties; (2) that the response to histamine is depressed by hypoxia; (3) that a substantial part of the immediate response, and most, if not all, of the residual response after 60 min is due to changes in lung tissue viscoelastic properties.

Airway Resistance↗

Rapid detection of cytomegalovirus DNA in cerebrospinal fluid of AIDS patients with neurologic disorders.

A polymerase chain reaction (PCR)-based method was used to detect cytomegalovirus (CMV) DNA in 82 cerebrospinal fluid (CSF) samples from 67 patients infected by human immunodeficiency virus (HIV). The test was positive for 14 patients, 8 of whom had CMV-related neurologic disease proven by viral culture of CSF or histologic examination. Encephalitis was the most frequent manifestation in patients with positive PCR results, but CMV DNA was also present in some patients with peripheral neuropathy or polyradiculomyelitis. All patients with proven CMV neurologic disease were positive by PCR. In contrast, viral culture was negative for 4 of the 8 patients and pathologic studies were available only for 5. The specificity of the PCR-based assay could not be assessed precisely because of the lack of a reference standard, but the results correlated well with clinical course and results of the other methods. These findings suggest that the PCR-based method may be a useful noninvasive tool for the rapid diagnosis of CMV-related neurologic disease.

AIDS-Related Opportunistic Infections↗

Respiratory transfer impedance and derived mechanical properties of conscious rats.

A setup is described for measuring the respiratory transfer impedance of conscious rats in the frequency range 16-208 Hz. The rats were placed in a restraining tube in which head and body were separated by means of a dough neck collar. The restraining tube was placed in a body chamber, allowing the application of pseudorandom noise pressure variations to the chest and abdomen. The flow at the airway opening was measured in a small chamber connected to the body chamber. The short-term reproducibility of the transfer impedance was tested by repeated measurements in nine Wistar rats. The mean coefficient of variation for the impedance did not exceed 10%. The impedance data were analyzed using different models of the respiratory system of which a three-coefficient resistance-inertance-compliance model provided the most reliable estimates of respiratory resistance (Rrs) and inertance (Irs). The model response, however, departed systematically from the measured impedance. A nine-coefficient model best described the data. Optimization of this model provided estimates of the respiratory tissue coefficients and upper and lower airway coefficients. Rrs with this model was 13.6 +/- 1.0 (SD) kPa.l-1.s, Irs was 14.5 +/- 1.3 Pa.l-1.s2, and tissue compliance (Cti) was 2.5 +/- 0.5 ml/kPa. The intraindividual coefficient of variation for Rrs and Irs was 11 and 18%, respectively. Because most of the resistance and inertance was located in the airways (85 and 81% of Rrs and Irs, respectively), the partitioning in tissue and upper and lower airway components was rather poor. Our values for Rrs and Irs of conscious rats were much lower and our values for Cti were higher than previously reported values for anesthetized rats.

Airway Resistance↗

Respiratory mechanics studied by multiple linear regression in unsedated ventilated patients.

Respiratory mechanics during artificial ventilation are commonly studied with methods which require a specific respiratory pattern. An alternative is to analyse the relationship between tracheal pressure (P) and flow (V') by multiple linear regression (MLR) using a suitable model. The value of this approach was evaluated in 12 unsedated patients, mechanically-ventilated for acute respiratory failure, and most with a history of chronic obstructive or restrictive respiratory disease. After correction for the non-linear resistance of the endotracheal tube, the data were analysed with the linear first order model: P = P0 + E.V + R.V' where E and R are total respiratory elastance and resistance, and P0 is the static recoil pressure at end-expiration. After exclusion of the cycles which clearly exhibited muscular activity, a good fit was observed in 25 out of 36 records (relative root-mean-square error less than 10%); the values of E and R were reproducible within cycles, and consistent with the patient's condition and the ventilatory mode. The intrinsic positive end-expiratory pressure (PEEPi), as derived from P0 and the applied PEEP, averaged 1.1 +/- 1.0 hPa. Using more sophisticated models, allowing for mechanical non-homogeneity or non-linearity of R or E, rarely improved the fit and often provided unrealistic data. In several subjects the discrepancy between the data and the first order model was consistent with expiratory flow limitation, which may severely impair the analysis. We conclude that, except in the case of expiratory flow limitation, the method is useful for routine clinical use and better implemented with the simple linear model.

Aged↗

Within-breath variations of forced oscillation resistance in healthy subjects.

Respiratory resistance (Rrs) was measured by the forced oscillation technique at 10, 20 and 30 Hz in 54 healthy subjects. The sinusoidal pressure oscillations were applied around the head, rather than at the mouth, so as to minimize transmural pressure across extrathoracic airway walls and the corresponding artefact (Peslin et al., J Appl Physiol, 1985, 59, 1790-1795). The flow (V') and volume (V) dependences of Rrs during the respiratory cycle were analysed by least square regression according to: Rrs = K1 + 2.K2.[V']#- K3.V, where K1 and K2 are Rohrer's constants, and where K3 expresses the (negative) volume dependence of Rrs. The analysis was made separately on the inspiratory and expiratory phases. A good fit was usually found between the data and the model, with a root-mean-square error averaging 15% of the mean Rrs at 10 Hz. At all frequencies K2 and K3 were substantially and significantly larger, and K1 slightly lower during expiration than during inspiration. Rrs, K1 and K3 were minimum at 20 Hz, while K2 exhibited a strong positive frequency dependence. The decrease of Rrs from 10 to 20 Hz was entirely explained by the variations of its linear component, and its increase from 20 to 30 Hz was largely due to its flow dependent component. Both the phasic variations and the frequency dependence of the coefficients suggest that the model is purely descriptive and that coefficients K2 and K3 reflect a number of phenomena, including the variations in glottic aperture during the respiratory cycle.

Adult↗