PubMed Health⌕ Search

Biomedical subjects

C Duvivier

Publications and source records attributed to C Duvivier.

At least 73 records · Page 4Linked to original sources

[Effect of the association propofol-alfentanil on bronchial resistances in asthmatic patients].

The bronchial resistances in 17 patients scheduled for ENT surgery were studied during general anaesthesia carried out with propofol and alfentanil. There were nine controls, all free from any allergic pathology. The other eight had bronchial hyperreactivity, with clinical asthma (one or two crises a month) treated with bronchodilators. Two had a complete Fernand-Widal syndrome, and the remaining six documented allergic asthma. All the patients were premedicated with hydroxyzine 2 mg.kg-1 orally on the eve of surgery, and two hours beforehand. Those patients who were on bronchodilators were given their drugs as usual with the premedication. Because bronchial resistances were measured with the patient breathing spontaneously (forced oscillation technique), induction was carried out in two steps, first with propofol 1.5 mg.kg-1, followed, two minutes later, by alfentanil 7 micrograms.kg-1. Once the bronchial resistances had been assessed the patient was given a further 2 mg.kg-1 dose of propofol, and alfentanil 40 micrograms.kg-1. The patient was then intubated, and anaesthesia maintained with propofol 9 mg.kg-1.h-1, and alfentanil 15 micrograms.kg-1 every fifteen minutes. In all, bronchial resistances were measured on the day before surgery, after premedication but before the patient had been given any anaesthetic drug, two minutes after the first injection of propofol, two minutes after the first injection of alfentanil, and after extubation. There were no significant differences between the two groups. Despite the small number of patients included in this study, it would seem that hydroxyzine, propofol and alfentanil may be used safely in patients with hyperreactive bronchi.

Adult↗

Airways impedance during single breaths of foreign gases.

The changes in airways resistance (Raw) and inertance (Iaw) during single inspirations of pure methane, helium, neon, and ethane at a flow of 0.1 l/s were measured in six healthy subjects by use of a forced-oscillation technique. Raw and Iaw were computed from respiratory transfer impedance obtained at a frequency of 20 Hz by applying pressure oscillations at the chest and measuring flow at the mouth with a bag-in-box system. Compared with the air data, the changes of Iaw after inhalation of 500 ml of gas averaged -41.1% with methane, -82.8% with helium, -25.8% with neon, and +4.8% with ethane. These changes were slightly less than the changes in gas density (-45%, -86%, -31%, and +5%, respectively). The inhaled volumes at which 50% of the changes had occurred (V50) did not differ significantly among gases and were approximately 100 ml. For Raw the data were more noisy than for Iaw; they were discarded in two subjects because of a strong and irreproducible volume dependence in air. Consistent differences were seen between the remaining subjects, one of whom exhibited a predominant viscosity dependence of Raw, one a predominant density dependence, and two an intermediate pattern. V50s were larger for Raw than for Iaw, indicating a more peripheral distribution of Raw. For Raw, V50s were lower with helium than with methane, in agreement with the notion that density-dependent resistance is located mainly in the large airways. The results suggest that some information on the serial distribution of Raw and Iaw may be derived from impedance measurements with foreign gases.

Adult↗

Compared responses of rat lungs to step volume changes and to sinusoidal forcing.

Lung pressure-volume hysteresis of cat lungs has been found by Hildebrandt (J. Appl. Physiol. 28, 365-372, 1970) to be 20-50% larger than predicted from stress adaptation data on the basis of a viscoelastic model. We have reinvestigated this phenomenon in isolated rat lungs with a different approach, in which the approximation inherent to using a model is avoided : Lung transfer function was derived from the digitally-computed Laplace transform of the pressure decay following a step volume change and used to predict lung pressure-flow relationship in the frequency domain. The latter was expressed in terms of lung effective resistance (Rlc) and effective elastance (Elc), and compared to the observed values (Rl and El) in the frequency range 0.01-0.5 Hz. The measurements were made in 5 lungs at a transpulmonary pressure (Pl) of 0.5 kPa and in 5 others at a Pl of 0.8 kPa. Rl was found to be 23-41% larger than Rlc at Pl = 0.5 and 29-51% larger at Pl = 0.8. El did not differ significantly from Elc at Pl = 0.5 but was 14-28% larger at Pl = 0.8. These results are in good agreement with previous findings. The differences between Rl and Rlc are proportional to the reciprocal of frequency and, thus, correspond to a rate-independent dissipation. They are consistent with a yield stress of 3-6 Pa.

Animals↗

Role of simulated repetitive coughing in mucus clearance.

The role of repetitive simulated coughing on the clearance of gel mucus simulant was investigated in vitro, by using a simulated cough machine. The repetition of cough induced a significant increase (p less than 0.01) in mucus simulant clearance (139.3 +/- 78.7 mm) in comparison to a single cough (24.9 +/- 27.5 mm). Moreover, the increase in frequency of the repetitive coughing induced a marked and significant increase in mucus simulant clearance (75.4 +/- 51.1 mm and 139.3 +/- 78.7 mm at 0.1 Hz and 1.6 Hz frequency, respectively). A significant (p less than 0.05) correlation was observed between the percentage increase of clearance and both shear-thinning index (r = 0.62) and the thixotropic index (r = 0.63). These results suggest that the shear-dependent properties of mucus, associated with a repetitive coughing, may increase the efficiency of mucus clearance by air flow mechanisms.

Cough↗

Thoracic gas volume at functional residual capacity measured with an integrated-flow plethysmograph in infants and young children.

Thoracic gas volume (TGV) was measured with an integrated flow plethysmograph in 15 infants aged 2-34 months. End-expiratory (TGVe) and end-inspiratory (TGVi) airway occlusions were compared, after correction of TGV for the occluded volume above functional residual capacity (FRC). The relationship between pressure at the airway opening (Pao) and volume displaced from the box during airway occlusion (Vg) was studied numerically by: 1) an algorithm including a correction for the drift of Vg and linear regression analysis (LR); and 2) Fourier analysis of the signals (FFT). TGVe was significantly higher than TGVi (256 vs 237 ml, 20.4 (square root of residual variance; p less than 0.002). The correlation coefficient of the Pao-Vg relationship was slightly but significantly higher for TGVi than for TGVe: 0.9968 (0.9937-0.9995) vs 0.9947 (0.9840-0.9990) (means and range). No difference was observed between LR and FFT, although the intra-individual coefficient of variation was lower for LR than FFT: 5.2% (1.6-11.3) vs 7.9% (1.9-21.0) (means and range). Model simulations suggested that the difference between TGVe and TGVi could be mainly attributed to gas compression in the instrumental deadspace and upper airway wall motion and/or to uneven distribution of alveolar and pleural pressure associated with chest wall distortion.

Airway Resistance↗

Respiratory impedance to ambient pressure changes at low frequencies.

Respiratory impedance may be studied by measuring airway flow (Vaw) when pressure is varied at the mouth (input impedance) or around the chest (transfer impedance). A third possibility, which had not been investigated so far, is to apply pressure variations simultaneously at the two places, that is to vary ambient pressure (Pam). This provides respiratory impedance to ambient pressure changes (Zapc = Vaw/Pam). In that situation airway impedance (Zaw) and tissue impedance (Zt) are mechanically in parallel, and both are in series with alveolar gas impedance (Zg): Zapc = Zaw + Zg + Zaw.Zg/Zt. We assessed the frequency dependence of Zapc from 0.05 to 2 Hz in nine normal subjects submitted to sinusoidal Pam changes of 2-4 kPa peak to peak. The real part of Zapc (Rapc) was of 6.2 kPa.1(-1).s at 0.05 Hz and decreased to 1.9 kPa.1(-1).s at 2 Hz. Similarly the effective compliance (Capc), computed from the imaginary part of Zapc, decreased from 0.045 1.kPa-1 at 0.05 Hz to 0.027 1.kPa-1 at 2 Hz. Breathing against an added resistance of 0.46 kPa.1(-1).s exaggerated the negative frequency dependence of both Rapc and Capc. When values of airway resistance and inertance derived from transfer impedance data were introduced, Zapc was used to compute effective tissue resistance (Rt) and compliance (Ct). Rt was found to decrease from 0.32 to 0.15 kPa.1(-1).s and Ct from 1.11 to 0.64 1.kPa-1 between 0.25 and 2 Hz. Ct was slightly lower with the added resistance. These results are in good agreement with the data obtained by other approaches.

Adult↗

Stress adaptation and low-frequency impedance of rat lungs.

At transpulmonary pressures (Ptp) of 7-12 cmH2O, pressure-volume hysteresis of isolated cat lungs has been found to be 20-50% larger than predicted from their amount of stress adaptation (J. Hildebrandt, J. Appl. Physiol. 28: 365-372, 1970). This behavior is inconsistent with linear viscoelasticity and has been interpreted in terms of plastoelasticity. We have reinvestigated this phenomenon in isolated lungs from 12 Wistar rats by measuring 1) the changes in Ptp after 0.5-ml step volume changes (initial Ptp of 5 cmH2O) and 2) their response to sinusoidal pressure forcing from 0.01 to 0.67 Hz (2 cmH2O peak to peak, mean Ptp of 6 cmH2O). Stress adaptation curves were found to fit approximately Hildebrandt's logarithmic model [delta Ptp/delta V = A - B.log(t)] from 0.2 to 100 s, where delta V is the step volume change, A and B are coefficients, and t is time. A and B averaged 1.06 +/- 0.11 and 0.173 +/- 0.019 cmH2O/ml, respectively, with minor differences between stress relaxation and stress recovery curves. The response to sinusoidal forcing was characterized by the effective resistance (Re) and elastance (EL). Re decreased from 2.48 +/- 0.41 cmH2O.ml-1.s at 0.01 Hz to 0.18 +/- 0.03 cmH2O.ml-1.s at 0.5 Hz, and EL increased from 0.99 +/- 0.10 to 1.26 +/- 0.20 cmH2O/ml on the same frequency range. These data were analyzed with the frequency-domain version of the same model, complemented by a Newtonian resistance (R) to account for airway resistance: Re = R + B/ (9.2f) and EL = A + 0.25B + B . log 2 pi f, where f is the frequency.(ABSTRACT TRUNCATED AT 250 WORDS)

Adaptation, Physiological↗

Respiratory input and transfer mechanical impedances in patients with chronic obstructive pulmonary disease.

Total respiratory input (Zin) and transfer (Ztr) mechanical impedances were measured from 4-30 Hz in 9 patients with severe chronic obstructive pulmonary disease (COPD) and in 12 healthy subjects. Zin was obtained by applying a pressure input around the head to minimize transmural pressure across extrathoracic airway walls, and Ztr was obtained with a pressure input at the chest. In agreement with previous studies total respiratory compliance and inertance were decreased in patients, while effective input resistance was increased and exhibited a negative frequency dependence. Effective transfer resistance (Re(Ztr)) was also increased at all frequencies, and, in some patients, the Re(Ztr)-frequency curve was sigmoid in shape, which was never seen in normals. When Ztr was analysed with a six-coefficient monoalveolar model featuring tissue properties, alveolar gas compliance, and airways properties, the model fitted the data less closely in patients than in normals and, in the former, provided unrealistic coefficients. Such was also the case with a bialveolar model. A better fit with more realistic values for the coefficients was obtained in selected patients with a model where central and peripheral (Rp) airway resistance were separated by a shunt representing airway wall compliance (Cb): Cb was found to range from 0.029-0.062 l.kPa-1 and Rp represented 44-81% of total airway resistance.

Adult↗

Measurement of ventilatory mechanical impedance in infants using a head pressure generator.

Two methods of measuring ventilatory mechanical impedance (Z) by forced oscillations between 6 and 20 Hz were compared in 24 infants aged 2 to 49 months: 1) the application of pressure oscillations at the airway opening (Z1); and 2) the application of pressure oscillations around the head (Z2). The latter has been recently proposed to minimize the influence of compliant upper airway walls (Peslin et al., J Appl Physiol. 1985, 59:1790-1795). Ventilatory resistance and compliance (Rsb, Csb) were also obtained with the single breath method. The real part of Z1 (R1) was markedly lower than that of the corresponding Z2 (R2), at any frequency. R1 exhibited a systematic negative frequency dependence, in contrast with R2. At any frequency, the slope of the regression equation on Rsb was closer to unity for R2 than for R1. The imaginary part of Z1 (X1) was negative over the whole frequency interval, and negative values of inertance were derived from X1. X2 was negative at low and positive at high frequencies. Resonant frequency (mean +/- SD = 10.5 +/- 3.5 Hz) was always reached with Z2 and correlated negatively with body weight (r = -0.61). Inertance estimated from X2 was positive and correlated negatively with body height (r = -0.66). The compliance derived from Z1 (C1 = 3.35 +/- 2.32 10(-3) L.cm H2O-1) was not significantly different from that derived from Z2 (C2 = 2.99 +/- 2.02 10(-3) L.cm H2O-1). The marked difference observed between Z1 and Z2 is related to the importance of the upper airway shunt and may be explained by inaccuracies of both methods.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

A correction procedure for the asymmetry of differential pressure transducers in respiratory impedance measurements.

The usual setup for measuring respiratory input impedance requires a differential pressure transducer attached to a pneumotachograph. As, up to now, no data correction procedure has been devised to account for transducer asymmetry, a highly symmetrical transducer is required to obtain reliable impedance data. In this communication, a general model for the measuring system is presented. Its main feature is that differential pressure transducers are modeled as two input-one output systems. From the theoretical model, we defined a dynamic calibration and data correction procedure. This was tested using highly asymmetrical transducers (common-mode rejection ratio between 45 and 27 dB) to measure the impedance of two respiratory analogs. The latter were linear resistance (R), inertance (I), compliance (C) series models simulating a normal subject (R = 3.47 hPa.s.l-1, I = 1.45 Pa.s2.l-1, C = 18.6 ml.hPa-1) and an obstructive patient (R = 11.15 hPa.s.l-1, I = 1.28 Pa.s2.l-1, C = 18.5 ml.hPa-1). Results obtained applying the devised procedure (errors in R, I, and C always less than 4 percent) show that respiratory input impedance can be adequately measured if data are corrected for transducer asymmetry.

Airway Resistance↗

Lung impedance in healthy humans measured by forced oscillations from 0.01 to 0.1 Hz.

Lung impedance was measured from 0.01 to 0.1 Hz in six healthy adults by superimposing small-amplitude forced oscillations on spontaneous breathing. Measurements were made with an almost constant-volume input (160-180 ml) or with an almost constant-flow input (20-30 ml.s-1). No significant difference was found between the two conditions. Lung resistance (RL) sharply decreased from 0.97 kPa.l-1.s at 0.01 Hz to 0.27 kPa.l-1.s at 0.03 Hz and then mildly to 0.23 kPa.l-1.s at 0.1 Hz. Lung effective compliance (CL) decreased slightly and regularly from 0.01 Hz (2.38 l.kPa-1) to 0.1 Hz (1.93 l.kPa-1). The data were analyzed using a linear viscoelastic model adapted from Hildebrandt (J. Appl. Physiol. 28:365-372, 1970) and complemented by a Newtonian resistance (R): RL = R + B/(9.2f); CL = 1/(A + 0.25B + B.log2 pi f), where f is the frequency and B/A is an index of lung tissue viscoelasticity. A good fit was generally obtained, with an average difference of 10% between the observed and predicted values. The ratio B/A was not affected by the breathing and was 10.6 and 13.6% in the constant-volume and constant-flow conditions, respectively, which agrees with Hildebrandt's observations in isolated cat lungs. R was systematically larger than the plethysmographic airway resistance, suggesting that lung tissue resistance might also include a Newtonian component.

Adult↗

Human respiratory impedance from 8 to 256 Hz corrected for upper airway shunt.

Respiratory input impedance (Zrs) was measured from 8 to 256 Hz in 10 healthy subjects by a method that eliminated the shunt impedance of extrathoracic airway walls. It consisted of combining the data obtained with a pressure input at the mouth (standard method, Zst) and with a pressure input around the head (Zhg) Zrs = Zst.(Zp + Zhg)/(Zp + Zst) where Zp is the impedance of the mouthpiece and pneumotachograph. Large quantitative differences were observed between Zrs and Zst, demonstrating that the standard method is unreliable at such frequencies. The real part of Zrs increased from 2.6 +/- 0.8 cmH2O.l-1.s at 8 Hz to a maximum of 38 +/- 19 cmH2O.l-1.s at 158 +/- 49 Hz. The imaginary part exhibited a maximum of 19 +/- 8 cmH2O.l-1.s at 126 +/- 38 Hz, a resonance at 157 +/- 43 Hz, and a minimum of lambda 19 +/- 16 cmH2O.l-1.s at 185 +/- 45 Hz. The data were analyzed with five models featuring alveolar gas compressibility; tissue resistance, inertance, and compliance; and different representations of the airways with lumped and distributed parameters. All except the simplest (lumped frequency-dependent resistance) fitted the data equally well, but none provided reliable estimates of gas compliance. Three models gave a consistent description of the airway in terms of equivalent rigid tubes (cross-sectional area 3.5-3.7 cm2, length 47-51 cm). We conclude that high-frequency input impedance could prove useful in exploring the airways but not the peripheral lung.

Adult↗

The role of mucus sol phase in clearance by simulated cough.

Using a simulated cough machine, we analyzed the effect of adding tensio-active liquids as sol phase simulant on the clearance of gel mucus simulant by cough. Polysaccharides crosslinked with sodium tetraborate were used at different concentration as gel mucus simulant. A drop of gel mucus simulant was deposited either directly on the model trachea or on a sol phase layer simulant (2% sodium dodecyl sulfate in water). The clearance of the mucus simulants was quantified by observing the movement of marker particles in the gel layer. The viscoelastic properties of gel mucus simulants were determined by using a viscoelastometer (SEFAM). The adhesive properties were analyzed by means of the platinum ring technique. The wettability of the mucus simulants was quantified by the automatic measurement of the contact angle of the drop of gel on the model trachea. We found that the addition of a sol phase significantly decreased by about 50% the adhesivity and wettability of the gel mucus simulants. This decrease was associated with a marked enhancement of cough clearance, whatever the viscoelastic properties of the gel mucus simulants. These results suggest that the sol phase is essential in bronchial respiratory mucus clearance by the cough mechanism.

Adhesiveness↗

Mechanics of the ventilatory system in sedated infants: forced oscillations versus single-breath method.

The real--Re(Z)--and imaginary--Im(Z)--parts of the ventilatory system impedance were measured between 6 and 30 Hz in 18 normal infants and in 19 with airway obstruction. The intercept (R0) and slope (S) of the Re(Z)-frequency function, as well as inertance (I) and compliance (C) estimated from Im(Z), were compared with ventilatory system resistance (Rrs) and compliance (Crs) (single-breath method). R0 correlated significantly with Rrs (r = 0.86), although the slope of the regression equation was significantly lower than 1 (P less than 0.01). Negative frequency dependence of Re(Z) was observed in all subjects and a significant correlation was found between S and Rrs (r = -0.80). "Inertance" was negative in 20 subjects and correlated negatively with Rrs (r = -0.61). C correlated with Crs (r = 0.64) and with 1/Rrs (r = 0.85). The ratio of C to Crs (mean +/- SD = 0.168 +/- 0.082) also correlated with 1/Rrs (r = 0.51). The main characteristics of the total impedance/frequency function could be simulated with a model featuring the upper airway wall (Zuaw) in parallel with the ventilatory system (Zrs). It is suggested that the differential change in Zuaw and Zrs with growth accounts for the marked frequency dependence of Re(Z) as well as the inaccurate estimation of both I and C in this population.

Airway Resistance↗

Density dependence of respiratory input and transfer impedances in humans.

Total respiratory input (Zin) and transfer (Ztr) impedances were obtained from 4 to 30 Hz in 10 healthy subjects breathing air and He-O2. Zin was measured by applying pressure oscillations around the head to minimize the upper airway shunt and Ztr by applying pressure oscillations around the chest. Ztr was analyzed with a six-coefficient model featuring airways resistance (Raw) and inertance (Iaw), alveolar gas compressibility, and tissue resistance, inertance, and compliance. Breathing He-O2 significantly decreased Raw (1.35 +/- 0.32 vs. 1.74 +/- 0.49 cmH2O.l-1.s in air, P less than 0.01) and Iaw (0.59 +/- 0.33 vs. 1.90 +/- 0.44 x 10(-2) cmH2O.l-1.s2), but, as expected, it did not change the tissue coefficients significantly. Airways impedance was also separately computed by combining Zin and Ztr data. This approach demonstrated similar variations in Raw and Iaw with the lighter gas mixture. With both analyses, however, the changes in Iaw were more than what was expected from the change in density. This indicates that factors other than gas inertance are included in Iaw and reveals the short-comings of the six-coefficient model to interpret impedance data.

Airway Resistance↗

Measurement of alveolar gas volume by ambient pressure changes in isolated lungs.

Alveolar gas volume (AGV) may be measured in humans (Peslin et al., J. Appl. Physiol. 62: 359-363, 1987) by applying very slow sinusoidal variations of ambient pressure (delta Pam) around the body and studying the relationship between delta Pam and the resulting gas displacement at the mouth (delta Vaw): AGVapc = (PB.delta Vaw)/(delta Pam.cos phi), where AGVapc is AGV measured by ambient pressure changes, PB is barometric minus alveolar water vapor pressure, and phi is the phase angle between Pam and Vaw. The applicability of this method to excised lungs at various transpulmonary pressures was assessed in six rabbit lungs and three dog lobes by reference to AGV measurements by He dilution (AGVdil) and by a volumetric method (AGVvol). Except in one instance, AGVapc did not change significantly when the frequency of delta Pam was varied from 0.02 to 0.2 Hz. AGVapc was highly correlated (P less than 0.001) to both AGVdil and AGVvol. It did not differ significantly from AGVdil (81.4 +/- 50.6 vs. 80.2 +/- 44.2 ml) and was only marginally higher than AGVvol (64.6 +/- 26.9 vs. 62.4 +/- 24.4 ml, P less than 0.05). We conclude that the method usually provides accurate results in excised lung preparations. Its main advantages are that it does not require manipulating the lung or changing its volume and that the measurement takes less than 1 min.

Animals↗

Thoracic gas volume in rabbits by low-frequency ambient pressure changes.

R. Peslin et al. measured thoracic gas volume (TGV) in adults using a new method employing low-frequency ambient pressure changes (APC) (J. Appl. Physiol. 62: 359-363, 1987). We extended that methodology and then tested the hypothesis that this technique was applicable to small mammals. TGV [at functional residual capacity (FRC)] by APC and by conventional Boyle's law was compared in 12 rabbits. The rabbits were anesthetized, tracheostomized, intubated, and placed in a pressure plethysmograph. Although in the method of Peslin et al. box pressure was oscillated at a single frequency, in our extension box pressure was oscillated simultaneously at two frequencies (0.1 and 0.2 Hz). Flow at the airway opening consisted of rapid events due to spontaneous breathing, superposed on slower events due to the alveolar gas compression. The slower events were analyzed to yield alveolar gas compliance and, by Boyle's law, FRC. FRC by APC was highly correlated to FRC by conventional plethysmography (r = 0.85). Compared with the methodology of Peslin et al., our extension relaxes a key limitation and yields systematically higher estimates of FRC. We conclude that this method is applicable to small mammals, despite an inherently more compliant chest wall, and that the methodological extension improves the estimate of FRC.

Animals↗