PubMed Health⌕ Search

Biomedical subjects

C Etz

Publications and source records attributed to C Etz.

8 recordsLinked to original sources

The excor device - revival of an old system with excellent results.

OBJECTIVE: We report on our experience with the BerlinHeart Excor system in adults and paediatric patients who underwent placement of the mechanical support device under emergency conditions and demonstrate the exceptional advantages and the considerable versatility of the system. METHODS: Since 2003, 29 consecutive patients (25 adults and 4 infants) with ages ranging from 10 months to 54 years underwent implantation of an Excor system. Main underlying heart diseases in adults were acute myocardial infarction (n = 9), dilative cardiomyopathy (n = 6), acute myocarditis (n = 6), whereas most of the children suffered from dilative cardiomyopathy. Ten patients had undergone implantation of an extracorporeal membrane oxygenation system. RESULTS: In 26 cases, a left ventricular assist device (LVAD) was implanted, while 3 patients had biventricular support. The support interval of all patients surviving the perioperative period lasted from 30 to 412 days, mean period of support until heart transplantation or explantation was 184 +/- 117 days. Severe complications were rare. CONCLUSION: The Excor paracorporeal mechanical support system is an excellent and highly versatile device for the support of patients of all ages and different types of underlying heart disease in the mid-term and long-term. The implant procedure and the perioperative management are simple, and complication rates are low.

Adolescent↗

Cardiothoracic surgery after heart and heart-lung transplantation.

OBJECTIVE: We sought to examine our management and the outcomes of cardiothoracic procedures after heart and heart lung transplantation. METHODS: We performed a retrospective review of cardiothoracic surgical procedures carried out between 1990 and 2004 in patients who had previously undergone heart or heart-lung transplantation at our institution. RESULTS: Twenty-one out of 340 patients (6.2 %) were identified. Cardiothoracic surgery was performed 44.4 +/- 33 months (range 1 - 115 months) after transplantation. Predominant types of surgery were coronary artery bypass grafting due to allograft vasculopathy (n = 5), aortic surgery due to acute dissection (n = 3), biventricular assist device implantation due to acute rejection (n = 1), tricuspid valve repair (n = 1), multiple cardiac surgical procedures including coronary artery bypass grafting, retransplantation, and tricuspid valve replacement (n = 2), explantation of a functionless heterotopic transplanted heart (n = 1). Lung surgery was performed in six patients due to pneumonia (n = 2), primary lung carcinoma (n = 3), lung torsion following heart-lung transplantation (n = 1). All patients underwent either lobectomy or segmental lung resection. Single lung retransplantation (n = 2) after prior heart-lung transplantation due to bronchiolitis obliterans was performed. In one patient a pneumonectomy (n = 1) due to severe chronic rejection of the contralateral lung was performed. Six subsequent deaths after cardiothoracic procedures were recorded after 1, 4, 78, 163, 205, and 730 days, respectively. Causes of death were advanced carcinoma (n = 1), multi-organ failure due to sepsis (n = 2), sudden heart death (n = 2), and advanced heart failure (n = 1). Fifteen out of 21 patients having undergone cardiothoracic procedures (71.4 %) survived the observation period of 56.6 +/- 34 months (range 1 - 114). CONCLUSIONS: Reasons for cardiothoracic procedures after prior heart or heart-lung transplantation were allograft vasculopathy, aortic dissections years after transplantation, chronic rejection, and either lung infections or malignancies. Surgical repair can be performed with an acceptable operative risk and good long-term survival rates.

Cardiac Surgical Procedures↗

Harvest of the radial artery: technique of the skeletonization and pedicle preparation.

Nowadays, radial artery grafts play a significant role in coronary artery revascularization, however, harvesting techniques are not standardized. We developed various surgical techniques for radial artery harvesting considering the anatomic landmarks of the foramen, including conventional surgery (with scissors and clips) and procedures with ultrasonic scalpel and retrieving the radial artery graft in a pedicle or in a skeletonized manner.

Coronary Artery Bypass↗

Clinical situations demanding weaning from long-term ventricular assist devices.

OBJECTIVE: Ventricular assist devices are increasingly used to treat patients with acute or chronic end-stage heart failure. We report on circumstances, exemplified on four cases, where a surprisingly favorable clinical course of the patients ultimately demanded early explantation of the device, which was not anticipated prior to its implantation. METHODS: The four patients were provided with implantable (Micromed BeBakey trade mark, Incor trade mark ) and external pneumatically driven (Thoratec trade mark, Excor trade mark ) devices under emergency conditions and were listed for heart transplantation. RESULTS: All four patients had an unexpected recovery of myocardial pump function. After careful diagnostic evaluation, all device components were completely removed without extracorporeal circulation. No stepwise weaning protocol was employed. CONCLUSIONS: Weaning patients from ventricular assist devices after recovery of myocardial pump function can become necessary. Diagnostic evaluation and the implementation of a weaning protocol is still a matter of debate, while complete surgical removal of all device components without extracorporeal circulation is possible with a low risk.

Acute Disease↗

First experience with rapamycin-based immunosuppression to improve kidney function after heart transplantation.

UNLABELLED: This study was designed to gain initial experience with rapamycin in thoracic organ transplant recipients with severely compromised kidney function, i.e. to see whether and how kidney function will improve with a rapamycin-based immunosuppressive protocol. METHODS: Twelve heart transplant patients were included into the study (serum creatinine > 2.5 mg/dL), with an average time after transplantation of more than 4 years. The calcineurin inhibitor (cyclosporine A = 9, tacrolimus = 3) was reduced by 50 %, and rapamycin added to reach a target level of 8 - 12 ng/dL. Azathioprine was halted, corticosteroid treatment remained unchanged. RESULTS: After implementing the rapamycin-based immunosuppression kidney function improved in all patients within one week. Serum creatinine dropped from 3.1 +/- 0.6 mg/dL to 2.7 +/- 0.5 mg/dL ( p = 0.0004), creatinine clearance increased from 30.4 +/- 11 mL/min to 40.8 +/- 10.5 mL/min ( p = 0.003). This improvement continued until 3 months after the conversion ( p = 0.032). Thereafter, no statistically significant changes were noted up to 6 months posttransplant ( p = 0.41). Serum cyclosporine levels dropped from 180 +/- 40 ng/mL to 132 +/- 46 ng/mL on average ( p = 0.002). Side-effects occurred in 4 patients and were all related to a rapamycin level exceeding 12 ng/mL. CONCLUSIONS: We conclude that transplant patients with impaired kidney function will have an immediate benefit from partially replacing calcineurin inhibitors by rapamycin.

Aged↗

Successful long-term bridge to transplant in a 5-year-old boy with the EXCOR left ventricular assist device.

We report on a 5-year-old boy who presented with postcardiotomy failure after aortic valve replacement and had to undergo implantation of a Berlin Heart-Excor system since treatment with ECMO did not improve myocardial pump function. After a stormy postoperative course with delayed sternal closure after 9 days, the young boy finally recovered and could be fully mobilized. Until successful heart transplantation after a support interval of 77 days, he experienced no device-related infectious or thromboembolic complications.

Aortic Valve Insufficiency↗

Evaluation of two oxygen analyzers by computerized data acquisition and processing.

Monitoring of inspired oxygen concentration during anesthesia with nitrous oxide is becoming accepted as essential. This type of monitoring demands accurate monitors that respond rapidly. We evaluated two such devices for their response patterns to rapid changes in oxygen concentration, a galvanic or "fuel cell" unit and a polarographic device. Data were stored after analog-to-digital conversion. The response patterns to stepwise changes in nitrous oxide and oxygen mixtures were recorded at flow rates ranging from 2 to 10 L/min. Both units responded accurately to all changes in the absolute oxygen concentration; the polarographic unit was, on average, twice as fast. Responsiveness to nitrous oxide was low (less than 0.4% at 100% nitrous oxide), and the stability of the signals was good. The 90% response time (T90) was consistent for any stepwise increase or decrease in oxygen concentration between 0, 21, 33, 50, and 100%. After a step change from 0 to 100% oxygen at a gas flow rate of 10 L/min, the T90 was 5.8 seconds in the polarographic device and 11.4 seconds in the galvanic device (p less than 0.01). After a decrease from 100 to 0% oxygen, the T90 was 0.6 second longer in both monitors. Comparing flow rates of 2 L/min with 10 L/min, the T90 was delayed by 1.1 and 2.3 seconds for an increase, and by 1.4 and 2.9 seconds for a decrease in oxygen concentration. Experimental data suggest that both sensors respond adequately during routine clinical use. The faster response of the polarographic device is probably of limited clinical relevance, but it may aid in calibration.

Anesthesia, General↗