PubMed Health⌕ Search

Biomedical subjects

C J Sprecher

Publications and source records attributed to C J Sprecher.

12 recordsLinked to original sources

Concordance study on population database samples using the PowerPlex 16 kit and AmpFlSTR Profiler Plus kit and AmpFlSTR COfiler kit.

Over 500 population database samples comprising African Americans, Bahamians, and Southwestern Hispanics were typed using the PowerPlex 16 and the Profiler Plus COfiler kits. There was only one sample in which a typing difference was observed. An FGA heterozygote profile was observed using the PowerPlex 16 primers, and a single allele FGA profile was observed using Profiler Plus primers. Thus, the extant data suggest that the primers used in the PowerPlex 16, Profiler Plus, and COfiler kits are reliable for typing reference samples destined for use in CODIS. In addition, African American, Bahamian, and Southwestern Hispanic databases have been established for the STR loci Penta D and Penta E. Both loci are highly polymorphic. The application of the product rule is valid for estimating the rarity of a multiple loci profile consisting of these two and the 13 core STR loci.

DNA Fingerprinting↗

TWGDAM validation of a nine-locus and a four-locus fluorescent STR multiplex system.

The Gene Print PowerPlex 1.1/Amelogenin and FFFL Fluorescent STR Systems have been validated following the recommendations presented by the Technical Working Group on DNA Analysis Methods (TWGDAM). The PowerPlex 1.1/Amelogenin System supports simultaneous amplification of eight short tandem repeat loci and the Amelogenin gender identification marker. The loci D16S539, D7S820, D13S317, and D5S818 are labeled with fluorescein (FL) while the loci CSF1PO, TP0X, TH01, vWA and Amelogenin are labeled with carboxy-tetramethylrhodamine (TMR). The FFFL Multiplex System is composed of the loci F13A01, FESFPS, F13B, and LPL, each labeled with fluorescein. We have observed no overlap of alleles across loci labeled with an individual fluorescent dye. Samples of each system were amplified and labeled in a single reaction, separated by electrophoresis through a denaturing polyacrylamide gel, and amplified alleles detected using a Hitachi FMBIO Fluorescent Scanner. Alterations from the standard amplification protocols in cycle number and annealing temperature generally produced excellent results. In experiments testing sensitivity as little as 0.2 ng of DNA template could be detected. As expected, different body fluids from the same individuals generated identical DNA profile results. Template DNA derived from blood-strains deposited on a variety of matrix supports displayed robust amplification except for material derived from deposits on wood and Japanese orchid leaves. Mixtures of DNA templates could be interpreted with the minor component present in as little as ten percent of the total sample. Monoplex and multiplex amplifications produced identical amplified allele patterns, indicating that STR multiplex systems save template and increase efficiency in the amplification procedure without loss of quality. Analyses of genotype frequencies in African-American, Caucasian-American and Hispanic-American populations using all twelve loci were used to determine matching probabilities smaller than 1 in 1.14 x 10(8) and 1 in 2658 for the PowerPlex 1.1 and the FFFL Multiplex Systems, respectively. The matching probability achieved with the two systems combined is smaller than 1 in 3.03 x 10(11). The independence of alleles within loci was generally demonstrated by applying the exact test to demonstrate Hardy-Weinberg Equilibrium. All of the studies performed indicate that the PowerPlex 1.1/Amelogenin and FFFL Multiplex Systems are powerful, robust, and reliable investigative tools that can be used in the analysis of forensic samples.

DNA Fingerprinting↗

Development and population study of an eight-locus short tandem repeat (STR) multiplex system.

Amplification of short tandem repeat (STR) loci has become a useful tool for human identification applications. To improve throughput and efficiency for such uses, the polymorphic STR loci CSF1PO, TPOX, TH01, vWA, D16S539, D7S820, D13S317, D5S818, F13A01, FESFPS, F13B, and LPL have been evaluated, developed, and configured into fluorescently labeled multiplex systems. Eight of these STR loci were combined to generate the PowerPlex System, a two-color multiplex system that supports rapid, accurate, reliable analysis and designation of alleles. The remaining four loci comprise the FFFL System, a one-color multiplex system. The PowerPlex System may be evaluated alternatively as two one-color, four-locus multiplex systems, CTTv Multiplex and GammaSTR Multiplex. The products of multiplex amplification may be analyzed with a variety of fluorescence detection instruments. Determination of genotypes of over 200 individuals from each of three different population/ethnic groups revealed independence of inheritance of the loci and allowed calculation of matching probability, typical paternity index, and power of exclusion for each multiplex.

Alleles↗

General approach to analysis of polymorphic short tandem repeat loci.

Polymerase chain reaction amplification products of 22 known polymorphic short tandem repeat (STR) loci were subjected to denaturing polyacrylamide gel electrophoresis and detected using a silver staining method. Loci that amplified efficiently and revealed the fewest amplification-related artifacts with this detection method were selected for development of allelic ladders. The combination of allelic ladders and silver stain detection provides an inexpensive and general non-isotopic analytical method for DNA identification. This approach has immediate application in forensic analysis, paternity determination, human cell line identification and monitoring of bone marrow transplants. It can also be adapted to more general applications of genetic analysis in human and other species including detection of genetic disorders and cancers.

Black or African American↗

Multiplex sets for the amplification of polymorphic short tandem repeat loci--silver stain and fluorescence detection.

Multiplex PCR amplification systems were developed using well-characterized, polymorphic short tandem repeat (STR) loci. Eight loci utilized in the multiplex amplifications included HUMCSF1PO, HUMTPOX, HUMTH01, HUMVWFA31, HUMF13A01, HUMFESFPS, HUMBFXIII and HUMLIPOL. From this list, three or four non-overlapping loci were simultaneously amplified, separated by denaturing polyacrylamide gel electrophoresis and visualized using silver stain or fluorescence detection. The multiplex PCR amplification systems offer a non-isotopic method for rapid, simple and accurate analysis of STR loci. This high-throughput method for DNA identification has immediate and valuable application in forensic analysis, paternity determination, tissue culture strain identification and bone marrow transplantation studies.

DNA↗

Validation of multiplex polymorphic STR amplification sets developed for personal identification applications.

Polymorphic short tandem repeat (STR) loci, which typically consist of variations in the number of 3-7 base pair repeats present at a site, provide an effective means of personal identification. Typing can be accomplished by amplification of genomic DNA using the polymerase chain reaction (PCR) and locus-specific primers, separation of amplified alleles using gel electrophoresis and their display using silver staining or fluorescent detection. Primers for several STR loci can be combined in a single multiplex reaction so typing of multiple loci can be accomplished rapidly and with less DNA than required if each locus were analyzed separately. Before such muliplex systems are used in forensic or paternity applications, it is desirable that they undergo testing for their reliability. This study evaluates the performance of two STR triplex systems, one containing the loci HUMCSF1PO, HUMTPOX, and HUMTH01, and the other containing HUMHPRTB, HUMFESFPS, and HUMVWFA31. Protocols for amplification of these two triplexes, and their corresponding monoplexes, were evaluated for sensitivity of detection, resistance to changes in the annealing temperature of the amplification protocol, and the ability to identify the minority contributor in amplification of mixed samples. In addition, five laboratories determined the alleles of twenty DNA samples, each extracted by one of four different extraction methods. The results illustrate that the two STR triplex systems and the monoplex systems contained within them can be used with as little as 0.25 ng of DNA template. Both triplexes amplified with 100% success using the Perkin Elmer Model 480 thermal cycler. With the GeneAmp 9600 System, the CTT triplex amplified with 100% success and the HFv triplex in 95.6% of attempts. These experiments meet many requirements for use in validation of DNA typing systems for forensic cases and paternity identification.

Anthropology, Physical↗

Swiss population data and forensic efficiency values on 3 tetrameric short tandem repeat loci-HUMTH01, TPOX, and CSF1PO-derived using a STR multiplex system.

Allele and genotype frequencies for 3 tetrameric short tandem repeat loci were determined in a Swiss population sample (n = 100) using the GenePrint STR Multiplex System, electrophoresis of the PCR products in DNA sequencing gels and subsequent detection of allelic fragments by silver staining. The loci are HUMTH01, TPOX, and CSF1PO. The observed heterozygosities are 83.0%, 60.0%, and 72.0%, respectively. The discrimination power determined for the individual loci is 0.914, 0.780, and 0.860, respectively, and the combined discrimination power for the triplex is 0.997. All loci meet Hardy-Weinberg expectations and after Bonferroni correction there was no evidence that the population sample deviates from expectations of independence. Moreover, independence of alleles at these STR loci with other PCR-based loci derived from the same Swiss population sample, previously reported, were considered. These loci were DQA1, LDLR, GYPA, HBGG, D7S8, GC and D1S80. Again, after Bonferroni correction there was no evidence that the population sample deviates from expectations of independence among alleles at the 10 different PCR-based loci. Thus, the allelic frequency data can be used in human identity testing to estimate the frequency of a multiple PCR-based DNA profile in the Swiss population.

Alleles↗

Allelic ladder characterization of the short tandem repeat polymorphism located in the 5' flanking region to the human coagulation factor XIII A subunit gene.

The short tandem repeat (STR) polymorphism present within the 5' untranslated region of the human coagulation factor XIII A subunit gene, HUMF13A01[AAAG]n, was evaluated using an allelic ladder, i.e., a standard size marker consisting of amplified alleles from the locus. The allelic ladder was constructed by pooling 12 polymerase chain reaction (PCR)-amplified alleles identified by their differential migration in denaturing polyacrylamide gel electrophoresis. This standard marker was used to distinguish 14 different alleles observed at this locus. Sequence analyses indicate that 13 of the alleles contain 4 through 16 iterations of the tandemly repeated AAAG sequence, respectively. The remaining allele carries four repeats and displays a deletion of two consecutive nucleotides (GT), one base distal to the repeat region. The allelic ladder was employed to type 326 F13A01 chromosomes rapidly and reliably in representatives of a German Caucasian population. Population data were analyzed with respect to Hardy-Weinberg Equilibrium (HWE) and compared with those of a previously studied Houston, Texas, Caucasian population.

Alleles↗

An oligonucleotide probe to assay lysis and DNA hybridization of a diverse set of bacteria.

A computer bank of 16 S rRNA bacterial sequences was searched to determine a consensus sequence expected to hybridize with DNA from a wide variety of bacteria. An oligonucleotide probe, named a panprobe, containing this sequence was used to assay the degree of lysis of bacterial colonies on filter paper heated in a microwave oven and subsequently treated with NaOH. As determined by colony hybridization with the panprobe, lysis was achieved for 51 of 59 different species of bacteria tested. DNA, isolated from the eight bacteria not detected by colony hybridization, did hybridize with the panprobe in slot blot hybridizations.

DNA, Bacterial↗