PubMed Health⌕ Search

Biomedical subjects

C M Schaefer

Publications and source records attributed to C M Schaefer.

14 recordsLinked to original sources

Turkey breeder hen age affects growth and systemic and intestinal inflammatory responses in female poults examined at different ages posthatch.

This trial examined the effect of 2 turkey breeder hen ages (33 or 55 wk of age) on performance, intestinal histology, and inflammatory immune response of female turkey poults grown to market weight. Using a randomized design, female poults were separated by breeder flock age (n = 8 floor pens/breeder flock age; n = 26 poults/pen; 0.195 m(2)/bird), fed identical commercial diets (9 phases), and grown to market weight (approximately 11.4 kg/ bird). At young ages, poults from the older breeder flock tended to have higher BW (P < 0.01 for d 7, P < 0.09 for d 63), although feed consumed was not significantly different due to breeder flock age (P > 0.20 for all ages). After approximately 63 d posthatch, no difference in BW was observed, suggesting that poults from the younger breeder flock were eventually able to compensate for initial reductions in performance. In addition to growth measurements on d 10, 24, and 65 posthatch, poults were vaccinated with lipopolysaccharide (LPS, from Salmonella Typhimurium; 0.5 mg/kg of BW intraabdominally) or not vaccinated (control), and intestinal histology and plasma haptoglobin were assessed at 24 h postadministration. In control birds, intestinal villus length was greater for poults from the older breeder flock (P < 0.05), as was crypt depth (P < 0.05 for d 11 and 25). Plasma haptoglobin levels did not change in 11-d-old poults after LPS administration, but they increased with LPS at d 25 and 66 posthatch (P < 0.05 for each). At d 66 posthatch, poults from the younger flock had increased haptoglobin levels post-LPS compared with those from the older breeder flock (P < 0.05). In general, LPS administration increased villus width in the jejunum and ileum (P < 0.05 for each), increased lamina propria width in the duodenum and ileum (P < 0.05 for each), and decreased ileum crypt depth (P < 0.05). Overall, poults from the older breeder flock had reduced inflammatory responses, even at 9 to 10 wk posthatch, even though performance was similar in poults from the 2 flocks by this age.

Aging↗

Application of AMBER in single- and dual-energy digital imaging: improvement in noise level and display dynamic range.

The combination of computed radiography (CR) and advanced multiple beam equalization radiography (AMBER) was evaluated for both single- and dual-energy chest radiography. The improved signal-to-noise ratio found with CR and AMBER resulted in a better visualization of structures in the mediastinum and basal lung than that found with CR alone. For the central lung, no improvement was seen. Because of the compressed dynamic range with CR and AMBER, contrast on hard copies and video monitors could be high without a sacrifice in image latitude. Dual-energy images showed a considerably lower noise level. The combined use of AMBER and CR promises to overcome the dynamic range limitations of digital displays while improving signal-to-noise ratio.

Artifacts↗

Improved parameters for unsharp mask filtering of digital chest radiographs.

Observer performance with four unsharp mask filtering algorithms for storage phosphor chest radiographs was compared with that with conventional screen-film radiographs in the detection of three types of simulated lung disease: nodules, fine lines, and micronodule clusters. Previously studied parameter sets (small [1.4-mm] and medium [5-mm] filter masks) and two new parameter sets (large [2.5-cm] and ultralarge [7-cm] masks) were compared by means of receiver operating characteristic analysis. With medium and small masks, nodule detection was inferior to that achieved with other modes. Use of ultralarge masks decreased the detection of lines compared with detection with conventional screen-film radiographs. Although detection of micronodule clusters was worse with digital images than with conventional screen-film radiographs, results with large and ultralarge masks were better than with small masks. Overall, filtering with large masks was best suited for simultaneously matching linear, nodular, and micronodular structures. These results suggest that lesion-specific processing of digital chest images is not necessary.

Humans↗

Renal arterial stenoses: spiral CT angiography.

PURPOSE: To evaluate the role of spiral computed tomography (CT) in diagnosis of renal arterial stenoses. MATERIALS AND METHODS: In 22 patients with suspected renovascular hypertension, spiral CT angiography of the renal arteries was compared with arterial digital subtraction angiography (DSA). For each patient, the peak transit time t (from intravenous injection to maximum enhancement of the abdominal aorta) was determined with a bolus injection of 15 mL of contrast medium. Spiral scanning started at the level of the superior mesenteric artery with a delay of t + 5 seconds after the start of injection of 100-150 mL of contrast medium. RESULTS: Spiral CT angiography demonstrated multiple renal arteries in five patients. A renal artery stenosis or occlusion was found in 15 of 22 patients (22 of 54 arteries). All findings were confirmed with arterial DSA. Vessel contrast on spiral CT scans was good to excellent in 19 of 22 patients. For diagnosis, axial-section and multiplanar reformatted images were superior to three-dimensional surface reconstructions and maximum-intensity projections. CONCLUSION: Spiral CT angiography is a promising screening method for renal artery stenosis.

Adult↗

Impact of hard-copy size on observer performance in digital chest radiography.

To determine the impact of reduced hard-copy size on diagnostic performance of digital radiography, screen-film chest radiographs were compared with isodose digital storage phosphor radiographs in the detection of simulated nodules, fine pulmonary lines, and micronodular opacities superimposed on the chests of 10 healthy volunteers. Digital radiographs were laser-printed in a full-size conventional format and in image lengths of two-thirds, one-half, and five-elevenths of the conventional format. Eighteen thousand observations by eight radiologists were analyzed by use of receiver operating characteristics. The detectability of lines and micronodular opacities decreased with declining image format size. In the detection of micronodular opacities, only the nearly full-size digital images were equivalent to conventional images. In the detection of linear opacities, reduction of image length by one-half or more reduced performance (analysis of variance, P less than .05). Only for the detection of nodules was no major difference found.

Humans↗

Hardware and software artifacts in storage phosphor radiography.

Hardware and software artifacts in digital radiographs acquired with storage phosphor systems can seriously impair image quality and imitate or mask abnormalities. These artifacts are caused by image plate, image reader, and laser printer defects; faulty image readout; processing errors; and unsharp masking. The artifacts can simulate calcifications and pneumothoraces or conceal low-contrast ill-defined lesions and subtle lesions along opacity interfaces. Hardware artifacts need to be recognized and properly traced to repair the system or improve its maintenance. Artifacts due to software characteristics and image post-processing must also be identified to ensure adequate system handling and adjustment of postprocessing algorithms.

Artifacts↗

Mediastinal abnormalities: detection with storage phosphor digital radiography.

Conventional film radiography (FR) and six postprocessing algorithms of isodose storage phosphor digital radiography (SR) (0.2-mm X 10-bit pixel matrix) were compared in the evaluation of 40 mediastinal and 30 pulmonary lesions in 60 patients who underwent computed tomography of the chest. The six SR algorithms varied among each other in only one image parameter. One algorithm approximated conventional image characteristics. The other five algorithms were designed to optimize imaging of the mediastinum and tested the effects of gray-scale reversal, adjustment of optical density, a linear instead of a sigmoid gradation curve, and moderate edge enhancement of high and medium spatial frequencies. Performance was evaluated by calculating the average area under the receiver operating characteristic curve (Az) of 5,040 observations by six readers. Post-processing with high-frequency edge enhancement and density optimization for the mediastinum significantly improved performance of SR over FR in the detection of mediastinal lesions (Az = .80 +/- .02 vs .73 +/- .01, respectively). Gray-scale reversal significantly decreased performance (Az = .64 +/- .03). All SR algorithms that were postprocessed to optimize imaging of the mediastinum were significantly inferior to FR in the detection of pulmonary lesions.

Algorithms↗

Interstitial lung disease: impact of postprocessing in digital storage phosphor imaging.

The ability to resolve the fine linear structures of interstitial lung disease is one measure of the limiting performance characteristics of an imaging system. Conventional screen-film radiography was compared with six algorithms of isodose storage phosphor digital radiography (0.2-mm x 10-bit pixel matrix) in the detection of interstitial lung abnormality documented by means of computed tomography in 40 patients with abnormalities and 25 healthy control subjects. Performance was evaluated with an analysis of variance (the Fisher paired comparison test; P less than .05) of the average receiver operating characteristic area of 2,730 observations by six readers. The moderately and the more markedly high-frequency edge-enhanced algorithms of storage phosphor digital radiographs were equivalent in performance to screen-film radiography. The default mode, low- and medium-frequency edge-enhanced algorithms, and gray scale reversed mode of storage phosphor digital radiography were inferior to screen-film radiography. The authors conclude that high-frequency edge-enhanced algorithms can perform as well as screen-film radiography in the detection of interstitial disease.

Algorithms↗

Detection of bullous lung disease: conventional radiography vs digital storage phosphor radiography.

The detection of fine linear contours and altered aeration are requirements for the radiologic diagnosis of bullous lung disease and are severe measures of the spatial and contrast resolution of chest imaging systems. We compared plain film radiography with five postprocessing algorithms of storage phosphor digital radiography (2144 x 1744 x 10 bit matrix with 0.2-mm pixel size) in the detection of CT-proved bullous lung disease (35 patients and 25 normal control subjects). Receiver-operating-characteristic analysis of 2160 observations by six interpreters was done to evaluate the observers' performance. By analysis of variance (p less than .05), we found that the default digital algorithm and the three edge-enhancing algorithms of high and medium frequencies performed less well than plain films did, but the differences fell short of statistical significance. Gray-scale reversal was the only digital algorithm that performed significantly less well than plain films did. We conclude that any differences between digital algorithms and plain films in the detection of bullous lung disease were too small to be detected in this study. Any difference between the two methods in providing clinically important, diagnostic information is likely to be insignificant.

Algorithms↗

Screening for asbestos-related pleural disease with digital storage phosphor radiography.

Digital storage phosphor radiography (SR) has a wide dynamic range and unique postprocessing capabilities that may improve the performance of screening studies for asbestos-related pleural disease compared with conventional film radiography (FR). In a group of 32 asbestos-exposed and nine control subjects with established pleural data, we compared the screening performance of FR and SR obtained with a single isoexposure, dual-energy technique (system resolution 0.2 mm, 10 bits). Performance was evaluated for 7320 observations by eight readers using a paired t test (P less than .02 with Bonferroni correction) of averaged receiver operating characteristic curve (ROC) areas (Az +/- standard error). We found that SR alone and SR supplemented by dual-energy soft-tissue and calcium images (SRde) were superior to FR in the overall detection of pleural abnormalities (Az = 0.90 +/- 0.01, 0.90 +/- 0.01, and 0.88 +/- 0.01, respectively). In the specific detection of pleural calcification, SRde was superior to FR (Az = 0.91 +/- 0.01 and 0.87 +/- 0.01, respectively; P less than 0.01). Analysis of variance indicated that SRde most closely reproduced an established pleural score based on the International Labor Organization (ILO) classification of the pneumoconioses (P less than 0.05, Scheffé's multiple comparison test). We conclude that isodose SR performs at least as well as FR in screening for asbestos-related pleural disease. SR supplemented by dual-energy images might improve the specific detection of pleural calcifications compared with FR.

Asbestosis↗

Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease.

The advantages of imaging the chest with digital storage phosphor radiography (SR) may be nullified by its spatial resolution, which is lower than that of conventional film radiography (FR). To test the reader detection performance with the two modalities under clinical conditions, the authors compared 140-kVp isoexposure SR (system resolution: 0.2 mm, 10 bits) and FR images of a variety of chest abnormalities proved by computed tomography (CT) (157 patients, 244 abnormalities, 5,652 observations, six readers). In all tests, SR was as good as or better than FR (P less than .05). In overall detection, indicated by the average area of receiver operating characteristics, SR and FR were equivalent. SR was superior for mediastinal lesions and for pulmonary opacities greater than 2 cm in diameter. For all other types of pulmonary lesions and pleural abnormalities, SR and FR were equivalent. Currently available commercial SR systems can replace film radiographic systems in the detection of a wide variety of chest lesions. SR is likely to enable better visualization than FR in the detection of mediastinal and large pulmonary abnormalities.

Female↗

Improved control of image optical density with low-dose digital and conventional radiography in bedside imaging.

The technical and diagnostic performance of simultaneously acquired low-dose (44% of standard dose) storage-phosphor digital radiographs (system resolution = 0.2 mm, 10 bits) were compared with those of standard-dose conventional bedside radiographs of the chest in 32 patients. The mean optical density (OD) of the lungs (800 measurements) was closer to the ideal density with digital radiography (1.45 OD +/- 0.20 [standard deviation] vs 1.75 OD +/- 0.53) and was less often outside the usable range (2.5% vs 42.5%). Receiver operating characteristic analysis for detection of simulated nodules and monitoring devices (nine readers, 4,608 observations) showed that digital radiography was superior to conventional radiography (P less than .05) for four of the nine readers and equivalent to conventional radiography for five readers. The authors concluded that digital radiography produces more consistent and ideal image density and performs at least as well as conventional radiography under phantom test conditions.

Absorptiometry, Photon↗